메뉴 건너뛰기




Volumn 12, Issue 4, 2003, Pages 495-502

Lower-intensity anticoagulation for mechanical heart valves: A new concept with the ATS bileaflet aortic valve

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; ANTICOAGULANT AGENT; TICLOPIDINE;

EID: 0042062267     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 0037312447 scopus 로고    scopus 로고
    • The initial experience with the ATS Medical Mechanical Cardiac Valve Prosthesis
    • Emery RW, Van Nooten GJ, Tesar PJ. The initial experience with the ATS Medical Mechanical Cardiac Valve Prosthesis. Ann Thorac Surg 2003;75:444-452
    • (2003) Ann. Thorac. Surg. , vol.75 , pp. 444-452
    • Emery, R.W.1    Van Nooten, G.J.2    Tesar, P.J.3
  • 2
    • 0031543374 scopus 로고    scopus 로고
    • Pulse duplicator hydrodynamics of four different bileaflet valves in mitral position
    • Verdonck PJ, Van Nooten GJ, Van Belleghem Y. Pulse duplicator hydrodynamics of four different bileaflet valves in mitral position. Cardiovasc Surg 1997;6:593-604
    • (1997) Cardiovasc. Surg. , vol.6 , pp. 593-604
    • Verdonck, P.J.1    Van Nooten, G.J.2    Van Belleghem, Y.3
  • 4
    • 0006126942 scopus 로고
    • Low risk of thrombosis and serious embolic events despite low-intensity anticoagulation: Experience with 1004 Medtronic Hall valves
    • Butchart EG, Lewis PA, Grunkemeier GL, Kutatilake N, Breckenridge I. Low risk of thrombosis and serious embolic events despite low-intensity anticoagulation: Experience with 1004 Medtronic Hall valves. Circulation 1988;78(suppl.I):166-177
    • (1988) Circulation , vol.78 , Issue.SUPPL. I , pp. 166-177
    • Butchart, E.G.1    Lewis, P.A.2    Grunkemeier, G.L.3    Kutatilake, N.4    Breckenridge, I.5
  • 5
    • 0028355636 scopus 로고
    • Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis
    • Horstkotte D, Schulte H, Bircks W, Strauer B. Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis. J Thorac Cardiovasc Surg 1994;107:1136-1145
    • (1994) J. Thorac. Cardiovasc. Surg. , vol.107 , pp. 1136-1145
    • Horstkotte, D.1    Schulte, H.2    Bircks, W.3    Strauer, B.4
  • 10
    • 0024546586 scopus 로고
    • Rates of thromboembolism with three different mechanical heart valve prosthesis; randomised study
    • Kuntze C, Ebels T, Eijgelaer A, Homan Van Der Heide JN. Rates of thromboembolism with three different mechanical heart valve prosthesis; randomised study. Lancet 1989;11:514-517
    • (1989) Lancet , vol.11 , pp. 514-517
    • Kuntze, C.1    Ebels, T.2    Eijgelaer, A.3    Homan Van Der Heide, J.N.4
  • 11
    • 0025851368 scopus 로고
    • Mechanical cardiac valvular prosthesis
    • Akins C. Mechanical cardiac valvular prosthesis. Ann Thorac Surg 1991;52:161-172
    • (1991) Ann. Thorac. Surg. , vol.52 , pp. 161-172
    • Akins, C.1
  • 12
    • 0028299329 scopus 로고
    • Twelve years experience with the St. Jude Medical valve prosthesis
    • Nakano K, Koyanagi H, Hashimoto A, et al. Twelve years experience with the St. Jude Medical valve prosthesis. Ann Thorac Surg 1994;57:697-703
    • (1994) Ann. Thorac. Surg. , vol.57 , pp. 697-703
    • Nakano, K.1    Koyanagi, H.2    Hashimoto, A.3
  • 13
    • 0025762084 scopus 로고
    • Comparison of two levels of anticoagulant therapy in patients with substitute heart valves
    • Altman R, Rouvier J, Garfunkel E, et al. Comparison of two levels of anticoagulant therapy in patients with substitute heart valves. J Thorac Cardiovasc Surg 1991;101:427-431
    • (1991) J. Thorac. Cardiovasc. Surg. , vol.101 , pp. 427-431
    • Altman, R.1    Rouvier, J.2    Garfunkel, E.3
  • 14
    • 0029851202 scopus 로고    scopus 로고
    • Comparison of high dose with low-dose aspirin in patients with mechanical heart valve replacement treated with oral anticoagulant
    • Altman R, Rouvier J, Gurfinkel E, Scazziota A, Turpie A. Comparison of high dose with low-dose aspirin in patients with mechanical heart valve replacement treated with oral anticoagulant. Circulation 1996;94:2113-2116
    • (1996) Circulation , vol.94 , pp. 2113-2116
    • Altman, R.1    Rouvier, J.2    Gurfinkel, E.3    Scazziota, A.4    Turpie, A.5
  • 15
    • 0023908222 scopus 로고
    • Shear-induced platelet aggregation can be mediated by von Willebrand factor released from platelets, as well as by exogenous large or unusual large vWF multimers, requires adenosine diphosphate, and is resistant to aspirin
    • Moake JL, Turner NA, Stathopoulos NA, Nolasco L, Hellums JD. Shear-induced platelet aggregation can be mediated by von Willebrand factor released from platelets, as well as by exogenous large or unusual large vWF multimers, requires adenosine diphosphate, and is resistant to aspirin. Blood 1988;71:1366-1374
    • (1988) Blood , vol.71 , pp. 1366-1374
    • Moake, J.L.1    Turner, N.A.2    Stathopoulos, N.A.3    Nolasco, L.4    Hellums, J.D.5
  • 16
    • 0023889381 scopus 로고
    • Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St. Jude Medical prosthesis
    • Okita Y, Miki S, Kusuhara K, et al. Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St. Jude Medical prosthesis. Ann Thorac Surg 1988;46:89-92
    • (1988) Ann. Thorac. Surg. , vol.46 , pp. 89-92
    • Okita, Y.1    Miki, S.2    Kusuhara, K.3
  • 17
    • 10244229121 scopus 로고    scopus 로고
    • AREVA: Multicenter randomized comparison of low-dose versus standard-dose anticoagulation in patients with mechanical prosthetic heart valves
    • Acar J, Iung B, Boissel JP, et al. AREVA: Multicenter randomized comparison of low-dose versus standard-dose anticoagulation in patients with mechanical prosthetic heart valves. Circulation 1996;94:2107-2116
    • (1996) Circulation , vol.94 , pp. 2107-2116
    • Acar, J.1    Iung, B.2    Boissel, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.