메뉴 건너뛰기




Volumn 5034, Issue , 2003, Pages 89-99

Performance comparisons of planar and volumetric observers for lesion detection in PET scanning

Author keywords

Comparisons of observer performance; Human and model observers; Planar and volumetric observers; Positron Emission Tomography (PET)

Indexed keywords

COMPUTER SIMULATION; MEDICAL IMAGING; MONTE CARLO METHODS; ONCOLOGY; POSITRON EMISSION TOMOGRAPHY;

EID: 0041858106     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480329     Document Type: Conference Paper
Times cited : (3)

References (13)
  • 2
    • 0003908115 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements, Bethesda, MD 54
    • ICRU, "Medical Imaging - The Assessment of Image Quality," International Commission on Radiation Units and Measurements, Bethesda, MD 54, 1996.
    • (1996) Medical Imaging - The Assessment of Image Quality
  • 3
    • 0034204856 scopus 로고    scopus 로고
    • Single-slice versus multi-slice display for human-observer lesion-detection studies
    • R. G. Wells, M. A. King, H. C. Gifford, and P. H. Pretorius, "Single-slice versus multi-slice display for human-observer lesion-detection studies," IEEE Trans. Nucl. Sci., vol. 47, pp. 1037-1044, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 1037-1044
    • Wells, R.G.1    King, M.A.2    Gifford, H.C.3    Pretorius, P.H.4
  • 6
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • C. E. Metz, "ROC methodology in radiologic imaging", Invest Radiol., pp. 720-733, 1986.
    • (1986) Invest Radiol. , pp. 720-733
    • Metz, C.E.1
  • 7
    • 0042846217 scopus 로고    scopus 로고
    • Rotationally symmetric vs. oriented frequency channels for the Hotelling observer: A comparison with human observers
    • K. J. LaCroix, B. M. W. Tsui, and E. C. Frey, "Rotationally symmetric vs. oriented frequency channels for the Hotelling observer: A comparison with human observers", IEEE Nuclear Science Symposium and Medical Imaging Conference Record, vol. 3, pp. 1402-6, 1999
    • (1999) IEEE Nuclear Science Symposium and Medical Imaging Conference Record , vol.3 , pp. 1402-1406
    • LaCroix, K.J.1    Tsui, B.M.W.2    Frey, E.C.3
  • 8
    • 0034049161 scopus 로고    scopus 로고
    • Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging
    • H. C. Gifford, M. A. King, D. J. de Vries, and E. J. Soares, "Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging," Journal of Nuclear Medicine, vol. 41, pp. 514-21., 2000.
    • (2000) Journal of Nuclear Medicine , vol.41 , pp. 514-521
    • Gifford, H.C.1    King, M.A.2    De Vries, D.J.3    Soares, E.J.4
  • 11
    • 0028999842 scopus 로고
    • Comparison of receiver operating characteristic and forced choice observer performance measurement methods
    • A. E. Burgess, "Comparison of receiver operating characteristic and forced choice observer performance measurement methods", Med. Phys., vol. 22, pp. 643-655, 1995.
    • (1995) Med. Phys. , vol.22 , pp. 643-655
    • Burgess, A.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.