메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages

A tumor detection observer study comparing 2D versus 3D whole-body PET imaging protocols

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; COMPUTER AIDED DIAGNOSIS; COMPUTER SIMULATION; DATA ACQUISITION; DOSIMETRY; IMAGE RECONSTRUCTION; MONTE CARLO METHODS; THREE DIMENSIONAL COMPUTER GRAPHICS; TUMORS; TWO DIMENSIONAL;

EID: 0034593613     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (19)
  • 1
    • 0026664443 scopus 로고
    • Whole-body positron emission tomography: Part I. Methods and performance characteristics
    • Dahlbom M, Hoffman E, Hoh C, Schiepers C, Rosenqvist G, Hawkins R, and Phelps M, "Whole-body Positron Emission Tomography: Part I. Methods and performance characteristics," J Nucl Med, Vol. 33, pp. 1191-1199, 1992.
    • (1992) J Nucl Med , vol.33 , pp. 1191-1199
    • Dahlbom, M.1    Hoffman, E.2    Hoh, C.3    Schiepers, C.4    Rosenqvist, G.5    Hawkins, R.6    Phelps, M.7
  • 2
    • 0026900597 scopus 로고
    • High sensitivity, total body PET scanning using 3D data acquisition and reconstruction
    • Cherry SR, Dahlbom M, and Hoffman EJ, "High sensitivity, total body PET scanning using 3D data acquisition and reconstruction," IEEE Trans Nucl Sci, Vol. 39, pp. 1088-1092, 1992.
    • (1992) IEEE Trans Nucl Sci , vol.39 , pp. 1088-1092
    • Cherry, S.R.1    Dahlbom, M.2    Hoffman, E.J.3
  • 3
    • 0029987698 scopus 로고    scopus 로고
    • Strategies to improve 3D whole-body PET image reconstruction
    • Cutler P and Xu M, "Strategies to improve 3D whole-body PET image reconstruction," Phys Med Biol, Vol. 41, pp. 1453-1467, 1996.
    • (1996) Phys Med Biol , vol.41 , pp. 1453-1467
    • Cutler, P.1    Xu, M.2
  • 6
    • 0033376809 scopus 로고    scopus 로고
    • ROC and localization ROC analyses of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm
    • Farquhar TH, Llacer J, Hoh CK, Czernin J, Gambhir SS, Seltzer MA, Silverman DH, Qi J, Hsu C, and Hoffman EJ, "ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm," J Nucl Med, Vol. 40, pp. 2043-52, 1999.
    • (1999) J Nucl Med , vol.40 , pp. 2043-2052
    • Farquhar, T.H.1    Llacer, J.2    Hoh, C.K.3    Czernin, J.4    Gambhir, S.S.5    Seltzer, M.A.6    Silverman, D.H.7    Qi, J.8    Hsu, C.9    Hoffman, E.J.10
  • 11
    • 0027842861 scopus 로고
    • Evaluation of cardiac cone-beam SPECT using observer performance experiments and ROC analysis
    • Tsui BMW, Terry JA, and Gullberg GT, "Evaluation of cardiac cone-beam SPECT using observer performance experiments and ROC analysis," Investigative Radiology, Vol. 28, pp. 1101-11012, 1993.
    • (1993) Investigative Radiology , vol.28 , pp. 1101-11012
    • Tsui, B.M.W.1    Terry, J.A.2    Gullberg, G.T.3
  • 14
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detecting and localizing target objects on images
    • Swensson RG, "Unified measurement of observer performance in detecting and localizing target objects on images," Med Phys, Vol. 23, pp. 1709-1725, 1996.
    • (1996) Med Phys , vol.23 , pp. 1709-1725
    • Swensson, R.G.1
  • 15
    • 0031076959 scopus 로고    scopus 로고
    • Evaluation of simulation-based scatter correction for 3D PET cardiac imaging
    • Watson CC, Newport D, Casey ME et al, "Evaluation of simulation-based scatter correction for 3D PET cardiac imaging," IEEE Trans Nucl Sci, Vol. NS 44, pp. 90-97, 1997.
    • (1997) IEEE Trans Nucl Sci , vol.NS44 , pp. 90-97
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3
  • 16
    • 0013447337 scopus 로고    scopus 로고
    • Noise equivalent count measurements for 2D and 3D whole-body PET using an anthropomorphic phantom
    • In preparation
    • Lartizien C, Comtat C, Trébossen R, Kinahan PE, Ferreira N, Bendriem B, "Noise Equivalent Count measurements for 2D and 3D Whole-Body PET using an anthropomorphic phantom," In preparation.
    • Lartizien, C.1    Comtat, C.2    Trébossen, R.3    Kinahan, P.E.4    Ferreira, N.5    Bendriem, B.6
  • 17
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts
    • Strother SC, Casey ME, Hoffman EJ, "Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts," IEEE Trans Nucl Sci, Vol. NS-37, pp. 783-788, 1990.
    • (1990) IEEE Trans Nucl Sci , vol.NS-37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 18
    • 0034204856 scopus 로고    scopus 로고
    • Single-slice versus multi-slice display for human observer lesion-detection studies
    • R.G. Wells, M.A. King, H.C. Gifford and P.H. Pretorius, "Single-slice versus multi-slice display for human observer lesion-detection studies," IEEE Trans Nucl Sci, Vol. NS-43, pp. 1037-1044, 2000.
    • (2000) IEEE Trans Nucl Sci , vol.NS-43 , pp. 1037-1044
    • Wells, R.G.1    King, M.A.2    Gifford, H.C.3    Pretorius, P.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.