Volumn 50, Issue 3, 2003, Pages 643-648

Block regional off-resonance correction (BRORC): A fast and effective deblurring method for spiral imaging

Author keywords

Blurring artifacts; MRI; Off resonance correction; Spiral

Indexed keywords

ELECTROMAGNETIC WAVE ATTENUATION; FAST FOURIER TRANSFORMS; IMAGE ENHANCEMENT; MAGNETIC RESONANCE IMAGING;

EID: 0041837647     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10570     Document Type: Article
Times cited : (20)

References (11)
  • 1
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med 1995;33:549-556.
    • (1995) Magn Reson Med , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 3
    • 0029098619 scopus 로고
    • Spiral imaging on a small-bore system at 4.7T
    • Spielman DM, Pauly JM. Spiral imaging on a small-bore system at 4.7T. Magn Reson Med 1995;34:580-585.
    • (1995) Magn Reson Med , vol.34 , pp. 580-585
    • Spielman, D.M.1    Pauly, J.M.2
  • 5
    • 0031002528 scopus 로고    scopus 로고
    • Multifrequency interpolation for fast off-resonance correction
    • Man LC, Pauly JM, Macovski A. Multifrequency interpolation for fast off-resonance correction. Magn Reson Med 1997;37:785-792.
    • (1997) Magn Reson Med , vol.37 , pp. 785-792
    • Man, L.C.1    Pauly, J.M.2    Macovski, A.3
  • 6
    • 0033811545 scopus 로고    scopus 로고
    • Rapid method for deblurring spiral MR images
    • Ahunbay E, Pipe JG. Rapid method for deblurring spiral MR images. Magn Reson Med 2000;44:491-494.
    • (2000) Magn Reson Med , vol.44 , pp. 491-494
    • Ahunbay, E.1    Pipe, J.G.2
  • 8
    • 0035186327 scopus 로고    scopus 로고
    • Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: Fast accurate gridding with noise and artifact reduction
    • Moriguchi H, Duerk JL. Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: fast accurate gridding with noise and artifact reduction. Magn Reson Med 2001;46:1189-1201.
    • (2001) Magn Reson Med , vol.46 , pp. 1189-1201
    • Moriguchi, H.1    Duerk, J.L.2
  • 9
    • 0043208122 scopus 로고    scopus 로고
    • Image reconstruction method without using interpolation in nonuniform sampled k-space MR imaging
    • Chicago
    • Moriguchi H, Wendt M, Duerk JL. Image reconstruction method without using interpolation in nonuniform sampled k-space MR imaging. In: Proc 85th Annual Meeting RSNA, Chicago, 1999, p 232.
    • (1999) Proc 85th Annual Meeting RSNA , pp. 232
    • Moriguchi, H.1    Wendt, M.2    Duerk, J.L.3
  • 10
    • 0032794555 scopus 로고    scopus 로고
    • Spiral reconstruction by regridding to a large rectilinear matrix: A practical solution for routine systems
    • Oesterle C, Markl M, Strecker R, Kraemer FM, Hennig J. Spiral reconstruction by regridding to a large rectilinear matrix: a practical solution for routine systems. J Magn Reson Imag 1999;10:84-92.
    • (1999) J Magn Reson Imag , vol.10 , pp. 84-92
    • Oesterle, C.1    Markl, M.2    Strecker, R.3    Kraemer, F.M.4    Hennig, J.5