메뉴 건너뛰기




Volumn 35, Issue 2, 1996, Pages 278-282

Inhomogeneity correction using an estimated linear field map

Author keywords

deblurring; field map; inhomogeneity; MRI

Indexed keywords

MAGNETIC RESONANCE IMAGING; MAXIMUM LIKELIHOOD ESTIMATION;

EID: 0030064662     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910350221     Document Type: Article
Times cited : (141)

References (21)
  • 1
    • 0019043355 scopus 로고
    • Spin warp NMR imaging and applications to human whole-body imaging
    • W. Edelstein, J. Hutchison, G. Johnson, T. Redpath, Spin warp NMR imaging and applications to human whole-body imaging. Phys. Med. Biol. 25, 751-756 (1980).
    • (1980) Phys. Med. Biol. , vol.25 , pp. 751-756
    • Edelstein, W.1    Hutchison, J.2    Johnson, G.3    Redpath, T.4
  • 2
    • 0021968447 scopus 로고
    • NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities
    • M. O'Donnell, W. Edelstein, NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. Med. Phys. 12, 20-26 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 20-26
    • O'Donnell, M.1    Edelstein, W.2
  • 3
    • 0022001875 scopus 로고
    • Volumetric NMR imaging with time-varying gradients
    • A. Macovski, Volumetric NMR imaging with time-varying gradients. Magn. Reson. Med. 2, 29-40 (1985).
    • (1985) Magn. Reson. Med. , vol.2 , pp. 29-40
    • Macovski, A.1
  • 4
    • 0023313536 scopus 로고
    • Fast magnetic resonance imaging with simultaneously oscillating and rotating gradients
    • S. Norton, Fast magnetic resonance imaging with simultaneously oscillating and rotating gradients. IEEE Trans. Med. Imaging MI-6, 21-31 (1987).
    • (1987) IEEE Trans. Med. Imaging , vol.MI-6 , pp. 21-31
    • Norton, S.1
  • 5
    • 0023984389 scopus 로고
    • Reconstruction by weighted correlation for MRI with time-varying gradients
    • A. Maeda, K. Sano, T. Yokoyama, Reconstruction by weighted correlation for MRI with time-varying gradients. IEEE Trans. Med. Imaging 7, 26-31 (1988).
    • (1988) IEEE Trans. Med. Imaging , vol.7 , pp. 26-31
    • Maeda, A.1    Sano, K.2    Yokoyama, T.3
  • 7
    • 0026399654 scopus 로고
    • A homogeneity correction method for magnetic resonance imaging with time-varying gradients
    • D. Noll, C. Meyer, J. Pauly, D. Nishimura, A homogeneity correction method for magnetic resonance imaging with time-varying gradients. IEEE Trans. Med. Imaging 10, 629-637 (1991).
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 629-637
    • Noll, D.1    Meyer, C.2    Pauly, J.3    Nishimura, D.4
  • 9
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in computer tomography
    • J. O'Sullivan, A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans. Med. Imaging MI, 200 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.MI , pp. 200
    • O'Sullivan, J.1
  • 10
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • J. Jackson, C. Meyer, D. Nishimura, A. Macovski, Selection of a convolution function for Fourier inversion using gridding. IEEE Trans. Med. Imaging 10, 473-478 (1991).
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 473-478
    • Jackson, J.1    Meyer, C.2    Nishimura, D.3    Macovski, A.4
  • 11
    • 0027235781 scopus 로고
    • Spatially resolved and localized real-time velocity distribution
    • P. Irarrazabal, B. Hu, J. Pauly, D. Nishimura, Spatially resolved and localized real-time velocity distribution. Magn. Reson. Med. 30, 207-212 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 207-212
    • Irarrazabal, P.1    Hu, B.2    Pauly, J.3    Nishimura, D.4
  • 12
    • 0023669873 scopus 로고
    • Spiral sampling in magnetic resonance imaging - The effect of inhomogeneities
    • E. Yudilevich, H. Stark, Spiral sampling in magnetic resonance imaging - the effect of inhomogeneities. IEEE Trans. Med. Imaging MI-6, 337-345 (1987).
    • (1987) IEEE Trans. Med. Imaging , vol.MI-6 , pp. 337-345
    • Yudilevich, E.1    Stark, H.2
  • 13
    • 0023749388 scopus 로고
    • Fast gradient-echo chemical-shift imaging
    • H. Park, Y. Kim, Z. Cho, Fast gradient-echo chemical-shift imaging. Magn. Reson. Med. 7, 340-345 (1988).
    • (1988) Magn. Reson. Med. , vol.7 , pp. 340-345
    • Park, H.1    Kim, Y.2    Cho, Z.3
  • 14
    • 0025832805 scopus 로고
    • Rapid in vivo proton shimming
    • E. Schneider, G. Glover, Rapid in vivo proton shimming. Magn. Reson. Med. 18, 335-347 (1991).
    • (1991) Magn. Reson. Med. , vol.18 , pp. 335-347
    • Schneider, E.1    Glover, G.2
  • 15
    • 0025881282 scopus 로고
    • Rapid, fully automatic, arbitrary-volume in vivo shimming
    • P. Webb, A. Macovski, Rapid, fully automatic, arbitrary-volume in vivo shimming. Magn. Reson. Med. 20, 113-122 (1991).
    • (1991) Magn. Reson. Med. , vol.20 , pp. 113-122
    • Webb, P.1    Macovski, A.2
  • 16
    • 0022260337 scopus 로고
    • A method for imaging of chemical shift or magnetic field distributions
    • R. Sepponen, A method for imaging of chemical shift or magnetic field distributions. Magn. Reson. Imaging 3, 163-167 (1985).
    • (1985) Magn. Reson. Imaging , vol.3 , pp. 163-167
    • Sepponen, R.1
  • 17
    • 0022189419 scopus 로고
    • NMR imaging for magnets with large nonuniformities
    • K. Sekihara, S. Matsui, H. Kohno, NMR imaging for magnets with large nonuniformities. IEEE Trans. Med. Imaging MI-4, 193-199 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.MI-4 , pp. 193-199
    • Sekihara, K.1    Matsui, S.2    Kohno, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.