Volumn 123, Issue 6, 2003, Pages 683-696

Patient selection for incus body coupling of a totally implantable middle ear implant

Author keywords

Active hearing implant; Amplifier implant; Ear endoprosthesis; Hearing amplifier implant; Hearing endoprosthesis; Implantable hearing device

Indexed keywords

ADULT; ARTICLE; AUDITORY ORIENTATION; CLINICAL ARTICLE; CONTROLLED STUDY; FOLLOW UP; HEARING LOSS; HUMAN; INCUS; MIDDLE EAR PROSTHESIS; NOISE; PATIENT SELECTION; PERCEPTION DEAFNESS; PRIORITY JOURNAL; PURE TONE AUDIOMETRY; QUESTIONNAIRE; SCORING SYSTEM; SOCIAL BEHAVIOR; SOUND; SPEECH DISCRIMINATION; VISUAL ANALOG SCALE;

EID: 0041425320     PISSN: 00016489     EISSN: None     Source Type: Journal    
DOI: 10.1080/00016480310002456     Document Type: Article
Times cited : (12)

References (34)
  • 1
    • 0032176073 scopus 로고    scopus 로고
    • A totally implantable hearing device for the treatment of sensorineural hearing loss: TICA LZ 3001
    • Leysieffer H, Baumann JW, Mayer R, et al. A totally implantable hearing device for the treatment of sensorineural hearing loss: TICA LZ 3001. HNO 1998; 46: 853-63.
    • (1998) HNO , vol.46 , pp. 853-863
    • Leysieffer, H.1    Baumann, J.W.2    Mayer, R.3
  • 2
    • 0031243371 scopus 로고    scopus 로고
    • An implantable piezoelectric hearing aid transducer for sensorineural hearing loss. Part II: Clinical implant
    • Leysieffer H, Baumann JW, Müller G, Zenner HP. An implantable piezoelectric hearing aid transducer for sensorineural hearing loss. Part II: Clinical implant. HNO 1997; 45: 801-15.
    • (1997) HNO , vol.45 , pp. 801-815
    • Leysieffer, H.1    Baumann, J.W.2    Müller, G.3    Zenner, H.P.4
  • 3
    • 0031243647 scopus 로고    scopus 로고
    • An implantable microphone for electronic hearing implants
    • Leysieffer H, Müller G, Zenner HP. An implantable microphone for electronic hearing implants. HNO 1997; 45: 816-27.
    • (1997) HNO , vol.45 , pp. 816-827
    • Leysieffer, H.1    Müller, G.2    Zenner, H.P.3
  • 4
    • 0032576350 scopus 로고    scopus 로고
    • Totally implantable hearing device for sensorineural hearing loss
    • Zenner HP, Leysieffer H. Totally implantable hearing device for sensorineural hearing loss. Lancet 1998; 352: 1751-2.
    • (1998) Lancet , vol.352 , pp. 1751-1752
    • Zenner, H.P.1    Leysieffer, H.2
  • 5
    • 0032177350 scopus 로고    scopus 로고
    • First implantations of a totally implantable electronic hearing system for sensorineural hearing loss
    • Zenner HP, Maassen MM, Plinkert PK, et al. First implantations of a totally implantable electronic hearing system for sensorineural hearing loss. HNO 1998; 46: 844-52.
    • (1998) HNO , vol.46 , pp. 844-852
    • Zenner, H.P.1    Maassen, M.M.2    Plinkert, P.K.3
  • 6
    • 0034051146 scopus 로고    scopus 로고
    • Effectiveness of totally implantable auditory prostheses in inner ear deafness
    • Zenner HP. Effectiveness of totally implantable auditory prostheses in inner ear deafness. HNO 2000; 48: 260-3.
    • (2000) HNO , vol.48 , pp. 260-263
    • Zenner, H.P.1
  • 7
    • 0034993012 scopus 로고    scopus 로고
    • Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss
    • Zenner HP, Leysieffer H. Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss. Otolaryngol Clin North Am 2001; 34: 417-46.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 417-446
    • Zenner, H.P.1    Leysieffer, H.2
  • 8
    • 0043156986 scopus 로고    scopus 로고
    • Implantable electromagnetic hearing transducer. US patent 5.554.09, 1996
    • Ball GR. Implantable electromagnetic hearing transducer. US patent 5.554.09, 1996.
    • Ball, G.R.1
  • 9
    • 0042656022 scopus 로고    scopus 로고
    • The vibrant® soundbridge-experience
    • Zurich, Switzerland
    • Cremers CWRJ, The Vibrant® Soundbridge-experience. Int Politzer Soc Meeting, Zurich, Switzerland, 1999.
    • (1999) Int Politzer Soc Meeting
    • Cremers, C.W.R.J.1
  • 11
    • 0028928707 scopus 로고
    • Ongoing investigations into an implantable electromagnetic hearing aid for moderate severe sensorineural hearing loss
    • Frederickson JM, Coticchia JM, Khosla S. Ongoing investigations into an implantable electromagnetic hearing aid for moderate severe sensorineural hearing loss. Otolaryngol Clin North Am 1995; 28: 107-20.
    • (1995) Otolaryngol Clin North Am , vol.28 , pp. 107-120
    • Frederickson, J.M.1    Coticchia, J.M.2    Khosla, S.3
  • 12
    • 0014712353 scopus 로고
    • An implantable hearing aid. State of the art
    • Goode RL. An implantable hearing aid. State of the art. Trans Am Acad Ophthalmol Otolaryngol 1970; 74: 128-39.
    • (1970) Trans Am Acad Ophthalmol Otolaryngol , vol.74 , pp. 128-139
    • Goode, R.L.1
  • 13
    • 0025109961 scopus 로고
    • Present status and outlook of the implantable hearing aid
    • Gyo K, Yanagihara N, Saiki T, Hinohira Y. Present status and outlook of the implantable hearing aid. Am J Otol 1990; 11: 250-3.
    • (1990) Am J Otol , vol.11 , pp. 250-253
    • Gyo, K.1    Yanagihara, N.2    Saiki, T.3    Hinohira, Y.4
  • 15
    • 0034981089 scopus 로고    scopus 로고
    • Semi-implantable electromagnetic middle ear device for moderate to severe sensorineural hearing loss
    • Hough J, Dyer RK Jr, Matthews P, Wood MW. Semi-implantable electromagnetic middle ear device for moderate to severe sensorineural hearing loss. Otolaryngol Clin North Am 2001; 34: 401-16.
    • (2001) Otolaryngol Clin North Am , vol.34 , pp. 401-416
    • Hough, J.1    Dyer R.K., Jr.2    Matthews, P.3    Wood, M.W.4
  • 16
    • 0001453454 scopus 로고
    • Evaluation of the implantable microphone in the cat
    • Kodera K, Suzuki JI, Ohno T. Evaluation of the implantable microphone in the cat. Adv Audiol 1988; 4: 117-23.
    • (1988) Adv Audiol , vol.4 , pp. 117-123
    • Kodera, K.1    Suzuki, J.I.2    Ohno, T.3
  • 17
    • 0029932573 scopus 로고    scopus 로고
    • State of the art on the development of the implantable hearing device for partial hearing loss
    • Maniglia AJ. State of the art on the development of the implantable hearing device for partial hearing loss. Otolaryngol Clin North Am 1996; 29: 225-44.
    • (1996) Otolaryngol Clin North Am , vol.29 , pp. 225-244
    • Maniglia, A.J.1
  • 18
    • 0028287131 scopus 로고
    • A contactless electromagnetic implantable middle ear device for sensorineural hearing loss
    • Manglia AJ, Ko WH, Rosenbaum M, et al. A contactless electromagnetic implantable middle ear device for sensorineural hearing loss. Ear Nose Throat J 1994; 73: 78-90.
    • (1994) Ear Nose Throat J , vol.73 , pp. 78-90
    • Manglia, A.J.1    Ko, W.H.2    Rosenbaum, M.3
  • 19
    • 0002783176 scopus 로고
    • Magnetic audition-auditory stimulation by means of alternating magnetic fields acting on a permanent magnet fixed to the eardrum
    • Rutschmann J. Magnetic audition-auditory stimulation by means of alternating magnetic fields acting on a permanent magnet fixed to the eardrum. IRE Trans Med Electron 1959; 6: 22-3.
    • (1959) IRE Trans Med Electron , vol.6 , pp. 22-23
    • Rutschmann, J.1
  • 20
    • 0032759926 scopus 로고    scopus 로고
    • First audiometric results with the Vibrant soundbridge, a semi-implantable hearing device for sensorineural hearing loss
    • Snik AF, Cremers CW. First audiometric results with the Vibrant soundbridge, a semi-implantable hearing device for sensorineural hearing loss. Audiology 1999; 38: 335-8.
    • (1999) Audiology , vol.38 , pp. 335-338
    • Snik, A.F.1    Cremers, C.W.2
  • 21
    • 0033989333 scopus 로고    scopus 로고
    • The effect of the "floating mass transducer" in the middle ear on hearing sensitivity
    • Snik FM, Cremers WR. The effect of the "floating mass transducer" in the middle ear on hearing sensitivity. Am J Otol 2000; 21: 42-8.
    • (2000) Am J Otol , vol.21 , pp. 42-48
    • Snik, F.M.1    Cremers, W.R.2
  • 22
    • 0028917948 scopus 로고
    • The round window electromagnetic implantable hearing aid approach
    • Spindel JH, Lambert PR, Ruth RA. The round window electromagnetic implantable hearing aid approach. Otolaryngol Clin North Am 1995; 28: 189-205.
    • (1995) Otolaryngol Clin North Am , vol.28 , pp. 189-205
    • Spindel, J.H.1    Lambert, P.R.2    Ruth, R.A.3
  • 23
    • 0028331818 scopus 로고
    • Long-term clinical results of the partially implantable piezzoelectric middle ear implant
    • Suzuki J, Kodera K, Nagai K, Yabe T. Long-term clinical results of the partially implantable piezzoelectric middle ear implant. Ear Nose Throat J 1994; 73: 104-7.
    • (1994) Ear Nose Throat J , vol.73 , pp. 104-107
    • Suzuki, J.1    Kodera, K.2    Nagai, K.3    Yabe, T.4
  • 25
    • 0028331946 scopus 로고
    • Implantation of electromagnetic ossicular replacement device
    • Tos M, Salomon G, Bonding P. Implantation of electromagnetic ossicular replacement device. Ear Nose Throat J 1994; 73: 92-103.
    • (1994) Ear Nose Throat J , vol.73 , pp. 92-103
    • Tos, M.1    Salomon, G.2    Bonding, P.3
  • 26
    • 0042656023 scopus 로고
    • Erstellung eines optimierten satztestes in deutscher sprache
    • Kollmeier B, ed. Heidelberg, Germany: Median
    • Wesselkamp W, Kliem K, Kollmeier B. Erstellung eines optimierten Satztestes in deutscher Sprache. In: Kollmeier B, ed. Moderne Verfahren der Sprachaudiometrie. Heidelberg, Germany: Median, 1992: 330-43.
    • (1992) Moderne Verfahren der Sprachaudiometrie , pp. 330-343
    • Wesselkamp, W.1    Kliem, K.2    Kollmeier, B.3
  • 27
    • 84973991447 scopus 로고
    • Eine methode zur bestimmung der hörschwellenamplituden des trommelfells bei verschiedenen frequenzen
    • Wilska A. Eine Methode zur Bestimmung der Hörschwellenamplituden des Trommelfells bei verschiedenen Frequenzen. Skand Arch Physiol 1935; 72: 161-5.
    • (1935) Skand Arch Physiol , vol.72 , pp. 161-165
    • Wilska, A.1
  • 28
    • 0000993138 scopus 로고
    • Efficacy of the partially implantable middle ear implant in middle and inner ear disorders
    • Yanigahara N, Yamanaka E, Sato H, Gyo K. Efficacy of the partially implantable middle ear implant in middle and inner ear disorders. Adv Audiol 1988; 4: 149-59.
    • (1988) Adv Audiol , vol.4 , pp. 149-159
    • Yanigahara, N.1    Yamanaka, E.2    Sato, H.3    Gyo, K.4
  • 30
    • 0022911068 scopus 로고
    • Speculation on the role of frequency in sound localization
    • Fuzessery ZM. Speculation on the role of frequency in sound localization. Brain Behav Evol 1986; 28: 95-108.
    • (1986) Brain Behav Evol , vol.28 , pp. 95-108
    • Fuzessery, Z.M.1
  • 31
    • 0032018929 scopus 로고    scopus 로고
    • Value of Schuller conventional roentgen diagnosis and computerized tomography of the temporal bone in preoperative diagnosis of the Tuebingen implantable cochlear amplifier
    • Maassen MM, Lehner R, Dammann F, Lüdke R, Zenner HP. Value of Schuller conventional roentgen diagnosis and computerized tomography of the temporal bone in preoperative diagnosis of the Tuebingen implantable cochlear amplifier. HNO 1998; 46: 22.
    • (1998) HNO , vol.46 , pp. 22
    • Maassen, M.M.1    Lehner, R.2    Dammann, F.3    Lüdke, R.4    Zenner, H.P.5
  • 32
    • 0042656021 scopus 로고    scopus 로고
    • Psychometric evaluation of the Gothenburg Profile for measurement of experienced hearing disability and handicap: Application with new hearing aid candidates and hearing aid users
    • Ringdahl A, Eriksson-Mangold M, Anderson G. Psychometric evaluation of the Gothenburg Profile for measurement of experienced hearing disability and handicap: application with new hearing aid candidates and hearing aid users. Br J Audiol 2001; 32: 371-81.
    • (2001) Br J Audiol , vol.32 , pp. 371-381
    • Ringdahl, A.1    Eriksson-Mangold, M.2    Anderson, G.3
  • 33
    • 0030608711 scopus 로고    scopus 로고
    • Ossicular chain coupling of an implantable hearing aid transducer using an ER:YAG-laser
    • Lehner R, Maassen MM, Plester D, Zenner HP. Ossicular chain coupling of an implantable hearing aid transducer using an ER:YAG-laser. HNO 1997; 45: 867-71.
    • (1997) HNO , vol.45 , pp. 867-871
    • Lehner, R.1    Maassen, M.M.2    Plester, D.3    Zenner, H.P.4
  • 34
    • 0034769325 scopus 로고    scopus 로고
    • Total implantation of the active hearing implant TICA for middle ear disease: A temporal bone study
    • Maassen MM, Lehner R, Leysieffer H, Baumann I, Zenner HP. Total implantation of the active hearing implant TICA for middle ear disease: a temporal bone study. Ann Otol Rhinol Laryngol 2001; 110: 912-6.
    • (2001) Ann Otol Rhinol Laryngol , vol.110 , pp. 912-916
    • Maassen, M.M.1    Lehner, R.2    Leysieffer, H.3    Baumann, I.4    Zenner, H.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.