Volumn 10, Issue 4, 2003, Pages 259-266

LOCS III examination at the slit lamp, do settings matter?

Author keywords

Cataract epidemiology; LOCS III grading system; Measurement variability; Slit lamp examination

Indexed keywords

ARTICLE; BRIGHTNESS; CATARACT; EPIDEMIOLOGICAL DATA; HUMAN; ILLUMINATION; LIGHT; MAJOR CLINICAL STUDY; OPHTHALMOSCOPY; PRIORITY JOURNAL; READING; REPRODUCIBILITY; SCORING SYSTEM; SLIT LAMP;

EID: 0041376522     PISSN: 09286586     EISSN: None     Source Type: Journal    
DOI: 10.1076/opep.10.4.259.15908     Document Type: Article
Times cited : (30)

References (10)
  • 1
    • 0024397438 scopus 로고
    • Lens opacities classification system II (LOCS II)
    • Chylack LT Jr., Leske MC, McCarthy D, et al. Lens opacities classification system II (LOCS II). Arch Ophthalmol. 1989;107:991-997.
    • (1989) Arch Ophthalmol , vol.107 , pp. 991-997
    • Chylack L.T., Jr.1    Leske, M.C.2    McCarthy, D.3
  • 2
    • 0027173798 scopus 로고
    • The Lens Opacities Classification System III
    • The Longitudinal Study of Cataract Study Group
    • Chylack LT Jr., Wolfe JK, Singer DM, et al. The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. Arch Ophthalmol. 1993;111:831-836.
    • (1993) Arch Ophthalmol , vol.111 , pp. 831-836
    • Chylack L.T., Jr.1    Wolfe, J.K.2    Singer, D.M.3
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0029316799 scopus 로고
    • Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT)
    • Chylack LT Jr., Wolfe JK, Friend J, et al. Validation of methods for the assessment of cataract progression in the Roche European-American Anticataract Trial (REACT). Ophthalmic Epidemiol. 1995;2:59-75
    • (1995) Ophthalmic Epidemiol , vol.2 , pp. 59-75
    • Chylack L.T., Jr.1    Wolfe, J.K.2    Friend, J.3
  • 5
    • 0027384252 scopus 로고
    • Quantitating cataract and nuclear brunescence, the Harvard and LOCS systems
    • Chylack LT Jr., Wolfe JK, Friend J, et al. Quantitating cataract and nuclear brunescence, the Harvard and LOCS systems. Optom Vis Sci. 1993;70:886-895.
    • (1993) Optom Vis Sci , vol.70 , pp. 886-895
    • Chylack L.T., Jr.1    Wolfe, J.K.2    Friend, J.3
  • 6
    • 0032869098 scopus 로고    scopus 로고
    • Grading nuclear cataract: Reproducibility and validity of a new method
    • Hall NF, Lempert P, Shier RP, et al. Grading nuclear cataract: reproducibility and validity of a new method. Br J Ophthalmol. 1999;83:1159-1163.
    • (1999) Br J Ophthalmol , vol.83 , pp. 1159-1163
    • Hall, N.F.1    Lempert, P.2    Shier, R.P.3
  • 7
    • 0027385061 scopus 로고
    • Evaluation of lens opacities classification system III applied at the slitlamp
    • Karbassi M, Khu PM, Singer DM, Chylack LT Jr. Evaluation of lens opacities classification system III applied at the slitlamp. Optom Vis Sci. 1993;70:923-928.
    • (1993) Optom Vis Sci , vol.70 , pp. 923-928
    • Karbassi, M.1    Khu, P.M.2    Singer, D.M.3    Chylack L.T., Jr.4
  • 8
    • 0031473453 scopus 로고    scopus 로고
    • LOCS III versus the Oxford Clinical Cataract Classification and Grading System for the assessment of nuclear, cortical and posterior subcapsular cataract
    • Hall AB, Thompson JR, Deane JS, Rosenthal AR. LOCS III versus the Oxford Clinical Cataract Classification and Grading System for the assessment of nuclear, cortical and posterior subcapsular cataract. Ophthalmic Epidemiol. 1997;4:179-194.
    • (1997) Ophthalmic Epidemiol , vol.4 , pp. 179-194
    • Hall, A.B.1    Thompson, J.R.2    Deane, J.S.3    Rosenthal, A.R.4
  • 10
    • 0026056642 scopus 로고
    • The effect of cataract severity and morphology on the reliability of the Lens Opacities Classification System II (LOCS II)
    • Maraini G, Pasquini P, Sperduto RD, et al. The effect of cataract severity and morphology on the reliability of the Lens Opacities Classification System II (LOCS II). Invest Ophthalmol Vis Sci. 1991;32: 2400-2403.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 2400-2403
    • Maraini, G.1    Pasquini, P.2    Sperduto, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.