메뉴 건너뛰기




Volumn 8, Issue 3, 2003, Pages 381-386

Correlation between femoral neck version and strain on the femur after insertion of femoral prosthesis

Author keywords

Anteversion; Modular; Strain gauge; Stress distribution; Total hip arthroplasty

Indexed keywords

ANALYTIC METHOD; ARTICLE; BIOMECHANICS; BONE STRESS; FEMUR NECK; TENSILE STRENGTH; TOTAL HIP PROSTHESIS; YOUNG MODULUS;

EID: 0038797795     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10776-002-0635-2     Document Type: Article
Times cited : (24)

References (22)
  • 1
    • 0030175796 scopus 로고    scopus 로고
    • Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis
    • Akay M, Aslan N. Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis. J Biomed Mater Res 1996;31:167-82.
    • (1996) J Biomed Mater Res , vol.31 , pp. 167-182
    • Akay, M.1    Aslan, N.2
  • 3
    • 0030757367 scopus 로고    scopus 로고
    • Effects of anteversion on femoral bone mineral density and geometry measured by dual energy X-ray absorptiometry: A cadaver study
    • Cheng XG, Nicholson HF, Boonen S, et al. Effects of anteversion on femoral bone mineral density and geometry measured by dual energy X-ray absorptiometry: a cadaver study. Bone 1997;21:113-17.
    • (1997) Bone , vol.21 , pp. 113-117
    • Cheng, X.G.1    Nicholson, H.F.2    Boonen, S.3
  • 4
    • 0029134888 scopus 로고
    • Bone remodeling in the proximal femur after Charnley total hip arthroplasty
    • Cohen B, Rushton N. Bone remodeling in the proximal femur after Charnley total hip arthroplasty. J Bone Joint Surg Br 1995;77:815-19.
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 815-819
    • Cohen, B.1    Rushton, N.2
  • 5
    • 0033978698 scopus 로고    scopus 로고
    • Medial cortex strain distribution during noncemented total hip arthroplasty
    • Elias JJ, Nagao M, Chu YH, et al. Medial cortex strain distribution during noncemented total hip arthroplasty. Clin Orthop 2000;370:250-8.
    • (2000) Clin Orthop , vol.370 , pp. 250-258
    • Elias, J.J.1    Nagao, M.2    Chu, Y.H.3
  • 6
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 1988;231:7-28.
    • (1988) Clin Orthop , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 7
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty
    • Engh CA, McGovern TF, Bodyn JD, et al. A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg Am 1992;74:1009-20.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bodyn, J.D.3
  • 8
    • 0024840370 scopus 로고
    • In vitro analysis of proximal femoral strains using PCA femoral implants and a hip-abductor muscles simulator
    • Finlay JB, Rorabeck CH, Bourne RB, et al. In vitro analysis of proximal femoral strains using PCA femoral implants and a hip-abductor muscles simulator. J Arthroplasty 1989;4:335-45.
    • (1989) J Arthroplasty , vol.4 , pp. 335-345
    • Finlay, J.B.1    Rorabeck, C.H.2    Bourne, R.B.3
  • 9
    • 0026230315 scopus 로고
    • An evaluation of three loading configurations for the in vitro testing of femoral strains in total hip arthroplasty
    • Finlay JB, Chess DG, Hardie WR, et al. An evaluation of three loading configurations for the in vitro testing of femoral strains in total hip arthroplasty. J Orthop Res 1991;9:749-59.
    • (1991) J Orthop Res , vol.9 , pp. 749-759
    • Finlay, J.B.1    Chess, D.G.2    Hardie, W.R.3
  • 10
    • 0035077903 scopus 로고    scopus 로고
    • Strain distribution in the proximal human femur
    • Kim Y, Kim J, Cho S. Strain distribution in the proximal human femur. J Bone Joint Surg Br 2001;83:295-301.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 295-301
    • Kim, Y.1    Kim, J.2    Cho, S.3
  • 11
    • 0030339451 scopus 로고    scopus 로고
    • Skeletal response to well fixed femoral components inserted with and without cement
    • Maloney WJ, Sychterz C, Bragdon C, et al. Skeletal response to well fixed femoral components inserted with and without cement. Clin Orthop 1996;333:15-26.
    • (1996) Clin Orthop , vol.333 , pp. 15-26
    • Maloney, W.J.1    Sychterz, C.2    Bragdon, C.3
  • 12
    • 0027944762 scopus 로고
    • Cortical bone density of the proximal femur following cementless total hip arthroplasty
    • McGovern TF, Engh CA, Zettl-Schaffer K, et al. Cortical bone density of the proximal femur following cementless total hip arthroplasty. Clin Orthop 1994;306:145-54.
    • (1994) Clin Orthop , vol.306 , pp. 145-154
    • McGovern, T.F.1    Engh, C.A.2    Zettl-Schaffer, K.3
  • 13
    • 0031172581 scopus 로고    scopus 로고
    • Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction
    • McNamara BP, Cristofolini L, Toni A, et al. Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. J Biomech 1997;30:621-30.
    • (1997) J Biomech , vol.30 , pp. 621-630
    • McNamara, B.P.1    Cristofolini, L.2    Toni, A.3
  • 14
    • 0030939339 scopus 로고    scopus 로고
    • Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty
    • Nishii T, Sugano N, Masuhara K, et al. Longitudinal evaluation of time related bone remodeling after cementless total hip arthroplasty. Clin Orthop 1996;339:121-31.
    • (1996) Clin Orthop , vol.339 , pp. 121-131
    • Nishii, T.1    Sugano, N.2    Masuhara, K.3
  • 15
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur
    • Oh I, Harris WH. Proximal strain distribution in the loaded femur. J Bone Joint Surg Am 1978;60:75-85.
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 75-85
    • Oh, I.1    Harris, W.H.2
  • 16
    • 0027137190 scopus 로고
    • Cementless total hip arthroplasty for congenitally dislocated or dysplastic hips
    • Paavilainen T, Hoikka V, Paavolainen P. Cementless total hip arthroplasty for congenitally dislocated or dysplastic hips. Clin Orthop 1993;297:71-81.
    • (1993) Clin Orthop , vol.297 , pp. 71-81
    • Paavilainen, T.1    Hoikka, V.2    Paavolainen, P.3
  • 17
    • 0028542455 scopus 로고
    • Femoral strain distribution and subsidence after physiological loading of a cementless canine femoral prosthesis: The effects of implant orientation, canal fill, and implant fit
    • Pernell RT, Gross RS, Milton JL, et al. Femoral strain distribution and subsidence after physiological loading of a cementless canine femoral prosthesis: the effects of implant orientation, canal fill, and implant fit. Vet Surg 1994;23:503-18.
    • (1994) Vet Surg , vol.23 , pp. 503-518
    • Pernell, R.T.1    Gross, R.S.2    Milton, J.L.3
  • 18
    • 0027947490 scopus 로고
    • Correlation of computed finite element stresses to bone density after remodeling around cementless femoral implants
    • Skinner HB, Kilgus DJ, Keyak J, et al. Correlation of computed finite element stresses to bone density after remodeling around cementless femoral implants. Clin Orthop 1994;305:178-89.
    • (1994) Clin Orthop , vol.305 , pp. 178-189
    • Skinner, H.B.1    Kilgus, D.J.2    Keyak, J.3
  • 19
    • 0031828510 scopus 로고    scopus 로고
    • The morphology of the femur in developmental dysplasia of the hip
    • Sugano N, Noble PC, Kamaric E, et al. The morphology of the femur in developmental dysplasia of the hip. J Bone Joint Surg Br 1998;80:711-19.
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 711-719
    • Sugano, N.1    Noble, P.C.2    Kamaric, E.3
  • 20
    • 0027628259 scopus 로고
    • Adaptive bone remodeling around bonded noncemented total hip arthroplasty: A comparison between animal experiments and computer simulations
    • Weinans H, Huiskeis R, van Rietbergen B, et al. Adaptive bone remodeling around bonded noncemented total hip arthroplasty: a comparison between animal experiments and computer simulations. J Orthop Res 1993;11:500-13.
    • (1993) J Orthop Res , vol.11 , pp. 500-513
    • Weinans, H.1    Huiskeis, R.2    Van Rietbergen, B.3
  • 21
    • 0028533208 scopus 로고
    • Effects of fit and bonding characteristics of femoral stems on adaptive bone remodeling
    • Weinans H, Huiskes R, Grootenboer HJ. Effects of fit and bonding characteristics of femoral stems on adaptive bone remodeling. J Biomech Eng 1994;116:393-400.
    • (1994) J Biomech Eng , vol.116 , pp. 393-400
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 22
    • 0031714325 scopus 로고    scopus 로고
    • Changes in bone mineral density adjacent to two biomechanically different types of cementless femoral stems in total hip arthroplasty
    • Zerahn B, Storgaard M, Johansen T, et al. Changes in bone mineral density adjacent to two biomechanically different types of cementless femoral stems in total hip arthroplasty. Int Orthop 1998;22:225-9.
    • (1998) Int Orthop , vol.22 , pp. 225-229
    • Zerahn, B.1    Storgaard, M.2    Johansen, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.