메뉴 건너뛰기




Volumn 74, Issue 4, 2003, Pages 233-239

The effects of varying examiner position on alternating cover test results

Author keywords

Examiner position; Heterophoria; Objective alternating cover test

Indexed keywords

ADULT; ARTICLE; BINOCULAR VISION; BODY POSITION; BODY POSTURE; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; STATISTICAL SIGNIFICANCE; VISION TEST; COMPARATIVE STUDY; EYE MOVEMENT DISORDER; METHODOLOGY; OBSERVER VARIATION; PHYSIOLOGY;

EID: 0038749507     PISSN: 15291839     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0344532068 scopus 로고
    • An experimental comparison of three common methods of measuring heterophoria
    • Weymouth FW. An experimental comparison of three common methods of measuring heterophoria. Am J Optom Phys Opt 1963;40:497-503.
    • (1963) Am J Optom Phys Opt , vol.40 , pp. 497-503
    • Weymouth, F.W.1
  • 2
    • 0020678420 scopus 로고
    • Analysis of seven methods of measuring the angle of deviation
    • Daum KM. Analysis of seven methods of measuring the angle of deviation. Am J Optom Phys Opt 1983;60:46-51.
    • (1983) Am J Optom Phys Opt , vol.60 , pp. 46-51
    • Daum, K.M.1
  • 3
    • 0030297111 scopus 로고    scopus 로고
    • How good is the estimated cover test at predicting the von Graefe phoria measurement?
    • Calvin H, Rupnow P, Grosvenor T. How good is the estimated cover test at predicting the von Graefe phoria measurement? Optom Vis Sci 1996;73:701-6.
    • (1996) Optom Vis Sci , vol.73 , pp. 701-706
    • Calvin, H.1    Rupnow, P.2    Grosvenor, T.3
  • 4
    • 0030176066 scopus 로고    scopus 로고
    • Reliability of and comparisons among methods of measuring dissociated phoria
    • Schroeder TL, Rainey BB, Goss DA, et al. Reliability of and comparisons among methods of measuring dissociated phoria. Optom Vis Sci 1996;73:389-97.
    • (1996) Optom Vis Sci , vol.73 , pp. 389-397
    • Schroeder, T.L.1    Rainey, B.B.2    Goss, D.A.3
  • 5
    • 0032192282 scopus 로고    scopus 로고
    • Inter-examiner repeatability of heterophoria tests
    • Rainey BB, Schroeder TL, Goss DA, et al. Inter-examiner repeatability of heterophoria tests. Optom Visi Sci 1998; 75:719-26.
    • (1998) Optom Visi Sci , vol.75 , pp. 719-726
    • Rainey, B.B.1    Schroeder, T.L.2    Goss, D.A.3
  • 6
    • 0036370480 scopus 로고    scopus 로고
    • Phoria variation secondary to cover test technique at near
    • Sparks BI III. Phoria variation secondary to cover test technique at near. Optometry 2002;73:51-4.
    • (2002) Optometry , vol.73 , pp. 51-54
    • Sparks III, B.I.1
  • 12
    • 0005692151 scopus 로고
    • Theoretical and clinical importance of proximal vergence and accommodation
    • Schor CM and Ciuffreda KJ, eds. Boston: Butterworth
    • Hokoda SC, Ciuffreda KJ. Theoretical and clinical importance of proximal vergence and accommodation. In: Schor CM and Ciuffreda KJ, eds. Vergence eye movements: basic and clinical aspects. Boston: Butterworth, 1983:76-7.
    • (1983) Vergence Eye Movements: Basic and Clinical Aspects , pp. 76-77
    • Hokoda, S.C.1    Ciuffreda, K.J.2
  • 14
    • 0020534488 scopus 로고
    • Ophthalmic prism: Measurement errors and how to minimize them
    • Thompson JT, Guyton DL. Ophthalmic prism: measurement errors and how to minimize them. Ophthalmology 1983;90:204-10.
    • (1983) Ophthalmology , vol.90 , pp. 204-210
    • Thompson, J.T.1    Guyton, D.L.2
  • 15
    • 0001368752 scopus 로고
    • Amount of eye movement objectively perceptible to the unaided eye
    • Ludvigh E. Amount of eye movement objectively perceptible to the unaided eye. Am J Opthalmol 1949;32:649-50.
    • (1949) Am J Opthalmol , vol.32 , pp. 649-650
    • Ludvigh, E.1
  • 16
    • 0034351448 scopus 로고    scopus 로고
    • Repeated measures of horizontal heterophoria
    • Howarth PA, Heron G. Repeated measures of horizontal heterophoria. Optom Vis Sci 2000;77:616-9.
    • (2000) Optom Vis Sci , vol.77 , pp. 616-619
    • Howarth, P.A.1    Heron, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.