메뉴 건너뛰기




Volumn 119, Issue 13, 2002, Pages 492-494

Accuracy of the automated oscillometric device Lohmeier B-606, for blood pressure measurement in hospitals;Validación del aparato oscilométrico Lohmeier B-606 para la medida de la presión arterial en el ámbito hospitalario

Author keywords

Accuracy; Blood pressure monitors; Hospital; Validation studies

Indexed keywords

MERCURY;

EID: 0038698611     PISSN: 00257753     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0025-7753(02)73472-6     Document Type: Article
Times cited : (3)

References (9)
  • 1
    • 0027218269 scopus 로고
    • The British Hypertension Society protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler W, De Swiet M, Padfield PL, Altman DG, et al. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11 (Suppl 2):43-62.
    • (1993) J. Hypertens , vol.11 , Issue.SUPPL. 2 , pp. 43-62
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    Altman, D.G.6
  • 2
    • 0003556412 scopus 로고
    • Electronic or automated sphygmomanometers
    • American National Standard Arlington: Association for the Advancement of Medical Instrumentation
    • American National Standard. Electronic or automated sphygmomanometers. Arlington: Association for the Advancement of Medical Instrumentation 1993.
    • (1993)
  • 3
    • 0028129011 scopus 로고
    • A comparison of the British Hypertension Society and Association for the Advancement of Medical Instrumentation protocols for validating blood pressure measuring devices: Can the two be reconciled?
    • O'Brien E, Atkins N. A comparison of the British Hypertension Society and Association for the Advancement of Medical Instrumentation protocols for validating blood pressure measuring devices: can the two be reconciled? J Hypertens 1994;12:1089-94.
    • (1994) J. Hypertens , vol.12 , pp. 1089-1094
    • O'Brien, E.1    Atkins, N.2
  • 4
    • 0034028579 scopus 로고    scopus 로고
    • Guidelines for the use of self-blood pressure monitoring: A summary report of the first international consensus conference
    • on behalf of the Organizing Committee and participants
    • Asmar R, Zanchetti A, on behalf of the Organizing Committee and participants. Guidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus conference. J Hypertens 2000;18:493-508.
    • (2000) J. Hypertens , vol.18 , pp. 493-508
    • Asmar, R.1    Zanchetti, A.2
  • 6
    • 0035992025 scopus 로고    scopus 로고
    • International protocol for validation of blood pressure measuring devices in adults
    • on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al, on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002;7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6
  • 7
    • 0009947474 scopus 로고    scopus 로고
    • La evaluación de la fiabilidad en las observaciones clínicas: El coeficiente de correlación intraclase
    • Prieto L, Lamarca R, Casado A. La evaluación de la fiabilidad en las observaciones clínicas: el coeficiente de correlación intraclase. Med Clin (Barc) 1998;110:142-5.
    • (1998) Med. Clin. (Barc) , vol.110 , pp. 142-145
    • Prieto, L.1    Lamarca, R.2    Casado, A.3
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring
    • O'Brien E, Waeber B, Parati G, Staessen J, Myers MG, on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001;322:531-6.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.