메뉴 건너뛰기




Volumn 6, Issue 2, 2003, Pages 65-70

Blood flow pattern and anastomotic compliance for interrupted versus continuous coronary bypass grafts

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ARTERY ANASTOMOSIS; ARTERY COMPLIANCE; ARTERY CONSTRICTION; ARTERY MALFORMATION; ARTERY WALL; ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; DIASTOLIC BLOOD PRESSURE; GEOMETRY; GRAFT PATENCY; HEART HEMODYNAMICS; INTERNAL MAMMARY ARTERY; INTRAVASCULAR ULTRASOUND; LEFT ANTERIOR DESCENDING CORONARY ARTERY; MALE; NONHUMAN; PRIORITY JOURNAL; PULSATILE FLOW; SURGICAL TECHNIQUE; SUTURING METHOD; VOLUMETRY;

EID: 0038664147     PISSN: 10983511     EISSN: None     Source Type: Journal    
DOI: 10.1532/hsf.740     Document Type: Article
Times cited : (17)

References (18)
  • 1
    • 0042200767 scopus 로고    scopus 로고
    • Compliance mismatch may promote graft artery intimal hyperplasia by altering suture-line stresses
    • Ballyk PD, Walsh C, Butany J, Ojha M. 1998. Compliance mismatch may promote graft artery intimal hyperplasia by altering suture-line stresses. J Biomech 31:229-37.
    • (1998) J. Biomech. , vol.31 , pp. 229-237
    • Ballyk, P.D.1    Walsh, C.2    Butany, J.3    Ojha, M.4
  • 3
    • 0036959929 scopus 로고    scopus 로고
    • Six-Month angiographic evaluation of beating-heart coronary arterial graft interrupted anastomoses using the Coalescent U-CLIP anastomotic device: A prospective clinical study
    • Caskey MP, Kirshner MS, Alderman EL, Hunsley SL, Daniel MA. 2002. Six-Month angiographic evaluation of beating-heart coronary arterial graft interrupted anastomoses using the Coalescent U-CLIP anastomotic device: a prospective clinical study. Heart Surg Forum 5:319-27.
    • (2002) Heart Surg. Forum , vol.5 , pp. 319-327
    • Caskey, M.P.1    Kirshner, M.S.2    Alderman, E.L.3    Hunsley, S.L.4    Daniel, M.A.5
  • 5
    • 0035353694 scopus 로고    scopus 로고
    • Facilitated coronary anastomosis using a nitinol U-Clip device: Bovine model
    • Hill AC, Maroney TP, Virmani R. 2001. Facilitated coronary anastomosis using a nitinol U-Clip device: bovine model. J Thorac Cardiovasc Surg 121:859-70.
    • (2001) J. Thorac. Cardiovasc. Surg. , vol.121 , pp. 859-870
    • Hill, A.C.1    Maroney, T.P.2    Virmani, R.3
  • 7
    • 0018564965 scopus 로고
    • Technique for performance of internal mammary artery-coronary artery anastomosis
    • Loop FD. 1979. Technique for performance of internal mammary artery-coronary artery anastomosis. J Thorac Cardiovasc Surg 78:460-3.
    • (1979) J. Thorac. Cardiovasc. Surg. , vol.78 , pp. 460-463
    • Loop, F.D.1
  • 8
    • 0022629896 scopus 로고
    • Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events
    • Loop FD, Lytle BW, Cosgrove DM, et al. 1986. Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events. N Engl J Med 314:1-6.
    • (1986) N. Engl. J. Med. , vol.314 , pp. 1-6
    • Loop, F.D.1    Lytle, B.W.2    Cosgrove, D.M.3
  • 9
    • 0032713270 scopus 로고    scopus 로고
    • Results of graft patency by immediate angiography in minimally invasive coronary artery surgery
    • 383-9 discussion
    • Mack MJ, Magovern JA, Acuff TA, et al. 1999. Results of graft patency by immediate angiography in minimally invasive coronary artery surgery. Ann Thorac Surg 68:383-9; discussion 389-90.
    • (1999) Ann. Thorac. Surg. , vol.68 , pp. 389-390
    • Mack, M.J.1    Magovern, J.A.2    Acuff, T.A.3
  • 10
    • 0021847447 scopus 로고
    • Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs
    • Morinaga K, Okadome K, Kuroki M, Miyazaki T, Muto Y, Inokuchi K. 1985. Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. J Vasc Surg 2:430-3.
    • (1985) J. Vasc. Surg. , vol.2 , pp. 430-433
    • Morinaga, K.1    Okadome, K.2    Kuroki, M.3    Miyazaki, T.4    Muto, Y.5    Inokuchi, K.6
  • 11
    • 0033794428 scopus 로고    scopus 로고
    • Histology and morphology of 59 internal thoracic artery grafts and their distal anastomoses
    • Ojha M, Leask RL, Johnston KW, David TE, Butany J. 2000. Histology and morphology of 59 internal thoracic artery grafts and their distal anastomoses. Ann Thorac Surg 70:1338-44.
    • (2000) Ann. Thorac. Surg. , vol.70 , pp. 1338-1344
    • Ojha, M.1    Leask, R.L.2    Johnston, K.W.3    David, T.E.4    Butany, J.5
  • 12
    • 0021591276 scopus 로고
    • A study of sequential anastomoses in aortocoronary bypass surgery - Internal configuration by the casting injection technique
    • Shioi, K, Washizu T, Kawamura M, Abe T, Iyomasa Y. 1984. A study of sequential anastomoses in aortocoronary bypass surgery - internal configuration by the casting injection technique. Thorac Cardiovasc Surg 32:18-22.
    • (1984) Thorac. Cardiovasc. Surg. , vol.32 , pp. 18-22
    • Shioi, K.1    Washizu, T.2    Kawamura, M.3    Abe, T.4    Iyomasa, Y.5
  • 14
    • 0035066205 scopus 로고    scopus 로고
    • Animal model to compare the effects of suture technique on cross- sectional compliance on end-to-side anastomoses
    • Tozzi P, Hayoz D, Ruchat P, et al. 2001. Animal model to compare the effects of suture technique on cross- sectional compliance on end-to-side anastomoses. Eur J Cardiothorac Surg 19:477-81.
    • (2001) Eur. J. Cardiothorac. Surg. , vol.19 , pp. 477-481
    • Tozzi, P.1    Hayoz, D.2    Ruchat, P.3
  • 16
    • 0032169739 scopus 로고    scopus 로고
    • Transit-time flow measurement for detection of early graft failure during myocardial revascularization
    • Walpoth BH, Bosshard A, Genyk I, et al. 1998. Transit-time flow measurement for detection of early graft failure during myocardial revascularization. Ann Thorac Surg 66:1097-100.
    • (1998) Ann. Thorac. Surg. , vol.66 , pp. 1097-1100
    • Walpoth, B.H.1    Bosshard, A.2    Genyk, I.3
  • 17
    • 0038420974 scopus 로고    scopus 로고
    • Interrupted anastomoses using a self-closing clip device: A multi-center prospective clinical trial
    • Presented at the 82nd Annual Meeting of the American Association for Thoracic Surgeons; May 5-8, 2002; Washington, DC, USA
    • Wolf RK, Alderman EL, Caskey MP, et al. 2002. Interrupted anastomoses using a self-closing clip device: a multi-center prospective clinical trial. Presented at the 82nd Annual Meeting of the American Association for Thoracic Surgeons; May 5-8, 2002; Washington, DC, USA.
    • (2002)
    • Wolf, R.K.1    Alderman, E.L.2    Caskey, M.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.