메뉴 건너뛰기




Volumn 71, Issue 2, 2003, Pages 165-173

Distortion correction for digital subtraction angiography imaging: PC based system for radiosurgery planning

Author keywords

IDL; Stereotactic; Super global model

Indexed keywords

COMPUTER OPERATING SYSTEMS; COMPUTER PROGRAMMING LANGUAGES; COMPUTER SOFTWARE; MEDICAL IMAGING; PERSONAL COMPUTERS; SURGERY;

EID: 0038634714     PISSN: 01692607     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0169-2607(02)00089-5     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0017128178 scopus 로고
    • Characterization of aberrations in image-intensified fluoroscopy
    • Casperson L.W., Spiegler P., Grollman J.H. Characterization of aberrations in image-intensified fluoroscopy. Med. Phys. 3:1976;103-106.
    • (1976) Med. Phys. , vol.3 , pp. 103-106
    • Casperson, L.W.1    Spiegler, P.2    Grollman, J.H.3
  • 2
    • 0021857762 scopus 로고
    • Digital subtraction angiography: Technology, equipment, and techniques
    • Ovitt T.W., Newell J.D. II. Digital subtraction angiography: technology, equipment, and techniques. Radiol. Clin. North Am. 23:1985;177-184.
    • (1985) Radiol. Clin. North Am. , vol.23 , pp. 177-184
    • Ovitt, T.W.1    Newell J.D. II2
  • 3
    • 0023234713 scopus 로고
    • Image intensifier distortion correction
    • Charkraborty D.P. Image intensifier distortion correction. Med. Phys. 14:1987;249-252.
    • (1987) Med. Phys. , vol.14 , pp. 249-252
    • Charkraborty, D.P.1
  • 4
    • 0025907199 scopus 로고
    • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain
    • Boone J.M., Seibert J.A., Barrett W.A., Blood E.A. Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain. Med. Phys. 18:1991;236-242.
    • (1991) Med. Phys. , vol.18 , pp. 236-242
    • Boone, J.M.1    Seibert, J.A.2    Barrett, W.A.3    Blood, E.A.4
  • 5
    • 0014399779 scopus 로고
    • Cerebral radiosurgery
    • Leksell L. Cerebral radiosurgery. Acta Chir. Scand. 134:1968;585-595.
    • (1968) Acta Chir. Scand. , vol.134 , pp. 585-595
    • Leksell, L.1
  • 6
    • 0029014292 scopus 로고
    • Automated and accurate assessment of the distribution, magnitude, and direction of pincushion distortion in angiographic images
    • van der Zwet P.M.J., Meyer D.J.H., Reiber J.H.C. Automated and accurate assessment of the distribution, magnitude, and direction of pincushion distortion in angiographic images. Invest. Radiol. 30:1995;204-212.
    • (1995) Invest. Radiol. , vol.30 , pp. 204-212
    • Van der Zwet, P.M.J.1    Meyer, D.J.H.2    Reiber, J.H.C.3
  • 7
    • 0031053552 scopus 로고    scopus 로고
    • Assessment of image intensifier and distortion for DSA localization studies
    • Coste E., Gibon D., Rousseau J. Assessment of image intensifier and distortion for DSA localization studies. Br. J. Radiol. 70:1997;70-73.
    • (1997) Br. J. Radiol. , vol.70 , pp. 70-73
    • Coste, E.1    Gibon, D.2    Rousseau, J.3
  • 8
    • 3543001025 scopus 로고    scopus 로고
    • Computer-aided radiation therapy simulation: Image intensifier spatial distortion correction for large field of view digital fluoroscopy
    • Cosby N.S., Leszczynski K.W. Computer-aided radiation therapy simulation: image intensifier spatial distortion correction for large field of view digital fluoroscopy. Phys. Med. Biol. 43:1998;2265-2278.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2265-2278
    • Cosby, N.S.1    Leszczynski, K.W.2
  • 9
    • 0030742408 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    • Fahrig R., Moreau M., Holdsworth D.W. Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion. Med. Phys. 24:1997;1097-1106.
    • (1997) Med. Phys. , vol.24 , pp. 1097-1106
    • Fahrig, R.1    Moreau, M.2    Holdsworth, D.W.3
  • 10
    • 0031455395 scopus 로고    scopus 로고
    • The accuracy and reproducibility of a global method to correct for geometric image distortion in the X-ray imaging chain
    • Gronenschild E. The accuracy and reproducibility of a global method to correct for geometric image distortion in the X-ray imaging chain. Med. Phys. 24:1997;1875-1888.
    • (1997) Med. Phys. , vol.24 , pp. 1875-1888
    • Gronenschild, E.1
  • 11
    • 0033430134 scopus 로고    scopus 로고
    • Correction for geometric image distortion in the X-ray imaging chain: Local technique versus global technique
    • Gronenschild E. Correction for geometric image distortion in the X-ray imaging chain: local technique versus global technique. Med. Phys. 26:1999;2602-2616.
    • (1999) Med. Phys. , vol.26 , pp. 2602-2616
    • Gronenschild, E.1
  • 12
    • 0032849383 scopus 로고    scopus 로고
    • Super-global distortion correction for a rotational C-arm X-ray image intensifier
    • Liu R.R., Rudin S., Bednarek D.R. Super-global distortion correction for a rotational C-arm X-ray image intensifier. Med. Phys. 26:1999;1802-1810.
    • (1999) Med. Phys. , vol.26 , pp. 1802-1810
    • Liu, R.R.1    Rudin, S.2    Bednarek, D.R.3
  • 13
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • Marquardt D.W. An algorithm for least-squares estimation of nonlinear parameters. SIAM J. Appl. Math. 11:1963;431-441.
    • (1963) SIAM J. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.