메뉴 건너뛰기




Volumn 43, Issue 8, 1998, Pages 2265-2278

Computer-aided radiation therapy simulation: Image intensifier spatial distortion correction for large field of view digital fluoroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER SIMULATION; GEOMETRY; IMAGE ANALYSIS; IMAGE INTENSIFIER; IMAGE RECONSTRUCTION; PRIORITY JOURNAL;

EID: 3543001025     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/43/8/019     Document Type: Article
Times cited : (21)

References (8)
  • 1
    • 0023234713 scopus 로고
    • Image intensifier distortion correction
    • Chakraborty D P 1987 Image intensifier distortion correction Med. Phys. 14 249-52
    • (1987) Med. Phys. , vol.14 , pp. 249-252
    • Chakraborty, D.P.1
  • 4
    • 0030742408 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
    • Fahrig R, Moreau M and Holdsworth D W 1997 Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion Med. Phys. 24 1097-106
    • (1997) Med. Phys. , vol.24 , pp. 1097-1106
    • Fahrig, R.1    Moreau, M.2    Holdsworth, D.W.3
  • 5
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM radiation therapy committee task group 40
    • Kutcher G J et al 1994 Comprehensive QA for radiation oncology: report of AAPM radiation therapy committee task group 40 Med. Phys. 21 581-619
    • (1994) Med. Phys. , vol.21 , pp. 581-619
    • Kutcher, G.J.1
  • 6
    • 0025908929 scopus 로고
    • Technical note: Development of video frame store and distortion correction facilities for an external-beam radiotherapy treatment simulator
    • Morton E J, Evans P M, Ferraro M, Young E F and Swindell W 1991 Technical note: development of video frame store and distortion correction facilities for an external-beam radiotherapy treatment simulator Br. J. Radiol. 64 747-50
    • (1991) Br. J. Radiol. , vol.64 , pp. 747-750
    • Morton, E.J.1    Evans, P.M.2    Ferraro, M.3    Young, E.F.4    Swindell, W.5
  • 8
    • 0025837262 scopus 로고
    • Accurate characterization of image intensifier distortion
    • Rudin S, Bednarek D R and Wong R 1991 Accurate characterization of image intensifier distortion Med. Phys. 18 1145-51
    • (1991) Med. Phys. , vol.18 , pp. 1145-1151
    • Rudin, S.1    Bednarek, D.R.2    Wong, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.