메뉴 건너뛰기




Volumn 13, Issue 4, 2002, Pages 585-594

A novel of osteosynthesis plate design for routine corrective facial surgery

Author keywords

Bone screws; Fracture fixation; Internal; Osteotomy

Indexed keywords

ADULT; BONE GRAFT; BONE PLATE; BONE SCREW; CLINICAL ARTICLE; DATA ANALYSIS; DEVICE REMOVAL; ESTHETICS; FACE DEFORMITY; FACE FRACTURE; FACE SURGERY; FEMALE; FRACTURE IMMOBILIZATION; FRACTURE TREATMENT; HUMAN; MALE; NEUROMUSCULAR FUNCTION; OSTEOSYNTHESIS MATERIAL; OSTEOTOMY; PILOT STUDY; POSTOPERATIVE CARE; PRIORITY JOURNAL; REVIEW; SURGICAL TECHNIQUE; TOOTH OCCLUSION; ARTICLE; BONE TRANSPLANTATION; CHIN; COMPARATIVE STUDY; ELECTRONICS; EQUIPMENT DESIGN; FACIAL BONE; INSTRUMENTATION; MANDIBLE; MAXILLA; MAXILLA OSTEOTOMY; PEROPERATIVE CARE; PLASTIC SURGERY; PROSPECTIVE STUDY; RETROSPECTIVE STUDY; SURFACE PROPERTY; ZYGOMA;

EID: 0038479943     PISSN: 10492275     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001665-200207000-00023     Document Type: Review
Times cited : (8)

References (63)
  • 1
    • 0037854834 scopus 로고    scopus 로고
    • Etiology and changing patterns of maxillofacial trauma
    • Ward Booth P, Schendel SA, Hausamen JA (eds). Section 1. Trauma. Edinburgh: Churchill Livingstone
    • Thomas DW, Michael Hill C. Etiology and changing patterns of maxillofacial trauma. In: Ward Booth P, Schendel SA, Hausamen JA (eds). Maxillofacial Surgery Volume 1, Section 1. Trauma. Edinburgh: Churchill Livingstone, 1999:3-10
    • (1999) Maxillofacial Surgery , vol.1 , pp. 3-10
    • Thomas, D.W.1    Michael Hill, C.2
  • 2
    • 0030455741 scopus 로고    scopus 로고
    • Experimental analysis of functional stability of sagittal split ramus osteotomies secured by miniplates and position screws
    • Shetty V, Freymiller E, McBrearty D, Caputo AA. Experimental analysis of functional stability of sagittal split ramus osteotomies secured by miniplates and position screws. J Oral Maxillofac Surg 1996;54:1317-1324
    • (1996) J. Oral Maxillofac. Surg. , vol.54 , pp. 1317-1324
    • Shetty, V.1    Freymiller, E.2    McBrearty, D.3    Caputo, A.A.4
  • 3
    • 0004972987 scopus 로고    scopus 로고
    • Entwicklung der modernen Osteosynthese
    • Luhr HG. Entwicklung der modernen Osteosynthese. Mund Kiefer Gesichtschir 2000;4 Suppl 1: S84-90
    • (2000) Mund Kiefer Gesichtschir , vol.4 , Issue.SUPPL. 1
    • Luhr, H.G.1
  • 4
    • 0033042188 scopus 로고    scopus 로고
    • Biodegradable osteosynthesis material for stabilization of midface fractures: Experimental investigation in sheep
    • Bähr W, Stricker A, Gutwald R, Wellens E. Biodegradable osteosynthesis material for stabilization of midface fractures: experimental investigation in sheep. J Craniomaxillofac Surg 1999;27:51-57
    • (1999) J. Craniomaxillofac. Surg. , vol.27 , pp. 51-57
    • Bähr, W.1    Stricker, A.2    Gutwald, R.3    Wellens, E.4
  • 7
    • 0032902437 scopus 로고    scopus 로고
    • Six year's experience with the zygomatic 'sandwich' osteotomy for correction of malar deficiency
    • Mommaerts MY, Nadjmi N, Abeloos JV, Neyt LF. Six year's experience with the zygomatic 'sandwich' osteotomy for correction of malar deficiency. J Oral Maxillofac Surg 1999;57:8-13
    • (1999) J. Oral Maxillofac. Surg. , vol.57 , pp. 8-13
    • Mommaerts, M.Y.1    Nadjmi, N.2    Abeloos, J.V.3    Neyt, L.F.4
  • 8
    • 0026481895 scopus 로고
    • In vitro strength analysis of sagittal split osteotomy fixation: Noncompression monocortical plates versus bicortical position screws
    • Anucul B, Waite PD, Lemons JE. In vitro strength analysis of sagittal split osteotomy fixation: noncompression monocortical plates versus bicortical position screws. J Oral Maxillofac Surg 1992;50:1295-1299
    • (1992) J. Oral Maxillofac. Surg. , vol.50 , pp. 1295-1299
    • Anucul, B.1    Waite, P.D.2    Lemons, J.E.3
  • 9
    • 0028023785 scopus 로고
    • Evaluation of the SLOT-osteosynthesis technique in mandibular advancement. With focus on occlusion and lower lip sensibility
    • Mommaerts MY, Abeloos JS, De Clercq CA, Neyt LF. Evaluation of the SLOT-osteosynthesis technique in mandibular advancement. With focus on occlusion and lower lip sensibility. J Craniomaxillofac Surg 1994;22:281-285
    • (1994) J. Craniomaxillofac. Surg. , vol.22 , pp. 281-285
    • Mommaerts, M.Y.1    Abeloos, J.S.2    De Clercq, C.A.3    Neyt, L.F.4
  • 10
    • 0035234889 scopus 로고    scopus 로고
    • Effects of a modified sandblasting surface treatment on topographic and chemical properties of titanium surface
    • Li D, Liu B, Han Y, Xu K. Effects of a modified sandblasting surface treatment on topographic and chemical properties of titanium surface. Implant Dent 2001;10:59-64
    • (2001) Implant. Dent. , vol.10 , pp. 59-64
    • Li, D.1    Liu, B.2    Han, Y.3    Xu, K.4
  • 13
    • 0032926249 scopus 로고    scopus 로고
    • Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy
    • Peltoniemi HH, Tulamo RM, Toivonen T, Hallikainen D, Tormala P, Waris T. Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy. J Neurosurg 1999;90:910-917
    • (1999) J. Neurosurg. , vol.90 , pp. 910-917
    • Peltoniemi, H.H.1    Tulamo, R.M.2    Toivonen, T.3    Hallikainen, D.4    Tormala, P.5    Waris, T.6
  • 14
    • 0034219892 scopus 로고    scopus 로고
    • Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws
    • Matthew IR, Frame JW. Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000:90:33-38
    • (2000) Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. , vol.90 , pp. 33-38
    • Matthew, I.R.1    Frame, J.W.2
  • 15
    • 0032971146 scopus 로고    scopus 로고
    • Metalic fragments on the surface of miniplates and screws before insertion
    • Rays MS, Matthew IR, Frame JW. Metalic fragments on the surface of miniplates and screws before insertion. Br J Oral Maxillofac Surg 1999;37:14-18
    • (1999) Br. J. Oral Maxillofac. Surg. , vol.37 , pp. 14-18
    • Rays, M.S.1    Matthew, I.R.2    Frame, J.W.3
  • 19
    • 0025948561 scopus 로고
    • Titanium mesh (TiMesh) osteosynthesis: A fast and adaptable method of semi-rigid fixation
    • Patel MF, Langdon JD. Titanium mesh (TiMesh) osteosynthesis: a fast and adaptable method of semi-rigid fixation. Br J Oral Maxillofac Surg 1991;29:316-324
    • (1991) Br. J. Oral Maxillofac. Surg. , vol.29 , pp. 316-324
    • Patel, M.F.1    Langdon, J.D.2
  • 20
    • 0022413393 scopus 로고
    • The influence of induced micro-movement on the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micro-movement on the healing of experimental tibial fractures. J Bone Joint Surg 1985;67B: 650-655
    • (1985) J. Bone Joint Surg. , vol.67 B , pp. 650-655
    • Goodship, A.E.1    Kenwright, J.2
  • 22
    • 0038531231 scopus 로고
    • Stripping of thread in bone by commercial cortical self-tapping and pre-tapped screws
    • Bergmann G et al (eds) Proceedings of the Congress of the European Society of Biomechanics
    • Xu X, Cordey J, Rahn BA, Ziegler WJ. Stripping of thread in bone by commercial cortical self-tapping and pre-tapped screws. In: Bergmann G et al (eds): Proceedings of the Congress of the European Society of Biomechanics. Developments in Biomechanics, vol 3, 1990:52-59
    • (1990) Developments in Biomechanics , vol.3 , pp. 52-59
    • Xu, X.1    Cordey, J.2    Rahn, B.A.3    Ziegler, W.J.4
  • 24
    • 0030471171 scopus 로고    scopus 로고
    • Functional stability of sagittal split ramus osteotomies: Effects of positional screws size and placement configuration
    • Shetty V, Freymiller E, McBrearty D, Caputo AA. Functional stability of sagittal split ramus osteotomies: effects of positional screws size and placement configuration. J Oral Maxillofac Surg 1996;54:601-610
    • (1996) J. Oral Maxillofac. Surg. , vol.54 , pp. 601-610
    • Shetty, V.1    Freymiller, E.2    McBrearty, D.3    Caputo, A.A.4
  • 25
    • 0025351033 scopus 로고
    • Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study
    • Skinner R, Maybee J, Transfeldt E, Venter R, Chalmers W. Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 1990;15:195-201
    • (1990) Spine , vol.15 , pp. 195-201
    • Skinner, R.1    Maybee, J.2    Transfeldt, E.3    Venter, R.4    Chalmers, W.5
  • 26
    • 0034026975 scopus 로고    scopus 로고
    • Mechanical and biomechanical measurements of five currently available osteosynthesis systems of self-tapping screws
    • Saka B. Mechanical and biomechanical measurements of five currently available osteosynthesis systems of self-tapping screws. Br J Oral Maxillofac Surg 2000;38:70-75
    • (2000) Br. J. Oral Maxillofac. Surg. , vol.38 , pp. 70-75
    • Saka, B.1
  • 28
    • 0031885152 scopus 로고    scopus 로고
    • Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws
    • Weiler A, Windhagen HJ, Raschke MJ, Laumeyer A, Hoffmann RF. Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 1998;26:119-126
    • (1998) Am. J. Sports Med. , vol.26 , pp. 119-126
    • Weiler, A.1    Windhagen, H.J.2    Raschke, M.J.3    Laumeyer, A.4    Hoffmann, R.F.5
  • 29
    • 0028258268 scopus 로고
    • Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws
    • Daftari TK, Horton WC, Hutton WC. Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws. J Spinal Disord 1994;7:139-145
    • (1994) J. Spinal Disord. , vol.7 , pp. 139-145
    • Daftari, T.K.1    Horton, W.C.2    Hutton, W.C.3
  • 30
    • 0029101673 scopus 로고
    • Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws
    • Ryken TC, Clausen JD, Traynelis VC, Goel VK. Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws. J Neurosurg 1995;83:325-329
    • (1995) J. Neurosurg. , vol.83 , pp. 325-329
    • Ryken, T.C.1    Clausen, J.D.2    Traynelis, V.C.3    Goel, V.K.4
  • 33
    • 0015694102 scopus 로고
    • Mechanical factors influencing the holding power of screws in compact bone
    • Uhthoff HK. Mechanical factors influencing the holding power of screws in compact bone. J Bone Joint Surg 1973;55B: 633-639
    • (1973) J. Bone Joint Surg. , vol.55 B , pp. 633-639
    • Uhthoff, H.K.1
  • 34
    • 0027534732 scopus 로고
    • Torque and pull-out analysis of six currently available self-tapping and 'emergency' screws
    • Boyle JM 3d, Frost DE, Foley WL, Grady JJ. Torque and pull-out analysis of six currently available self-tapping and 'emergency' screws. J Oral Maxillofac Surg 1993;51:45-50
    • (1993) J. Oral Maxillofac. Surg. , vol.51 , pp. 45-50
    • Boyle J.M. III1    Frost, D.E.2    Foley, W.L.3    Grady, J.J.4
  • 35
    • 0004926960 scopus 로고
    • Internal fixation with plates and screws
    • Bechtol CO (ed) Baltimore: Williams & Wilkins
    • Bechtol CO. Internal fixation with plates and screws. In: Bechtol CO (ed) Metals and Engineering in Bone and Joint Surgery. Baltimore: Williams & Wilkins, 1959:162-164
    • (1959) Metals and Engineering in Bone and Joint Surgery , pp. 162-164
    • Bechtol, C.O.1
  • 36
    • 0024560263 scopus 로고
    • Morphologie des Knochengewindes nach Implantation von 2mm-AO-Minischrauben im Mittelgesicht
    • Bähr W. Morphologie des Knochengewindes nach Implantation von 2mm-AO-Minischrauben im Mittelgesicht. Unfallchirurg 1989;92:54-58
    • (1989) Unfallchirurg , vol.92 , pp. 54-58
    • Bähr, W.1
  • 37
    • 0015694102 scopus 로고
    • Mechanical factors influencing the holding power of screws in compact bone
    • Uhthoff HK. Mechanical factors influencing the holding power of screws in compact bone. J Bone Joint Surg 1973;55B: 663-669
    • (1973) J. Bone Joint Surg. , vol.55 B , pp. 663-669
    • Uhthoff, H.K.1
  • 38
    • 0025357365 scopus 로고
    • The effect of repetitive screw hole use on the retentive strength of pretapped and self-tapped screws
    • Foley WL, Frost DE, Tucker MR. The effect of repetitive screw hole use on the retentive strength of pretapped and self-tapped screws. J Oral Maxillofac Surg 1990;48:264-267
    • (1990) J. Oral Maxillofac. Surg. , vol.48 , pp. 264-267
    • Foley, W.L.1    Frost, D.E.2    Tucker, M.R.3
  • 39
    • 0031317908 scopus 로고    scopus 로고
    • Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit
    • Klokkevold PR, Nishimura RD, Adachi M, Caputo A. Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit. Clin Oral Implants Res 1997;8: 442-447
    • (1997) Clin. Oral Implants Res. , vol.8 , pp. 442-447
    • Klokkevold, P.R.1    Nishimura, R.D.2    Adachi, M.3    Caputo, A.4
  • 41
    • 0015378503 scopus 로고
    • The mechanical porperties of surgical bone screws and some aspects of insertion practice
    • Hughes AN, Jordan BA. The mechanical porperties of surgical bone screws and some aspects of insertion practice. Injury 1972;4:25-38
    • (1972) Injury , vol.4 , pp. 25-38
    • Hughes, A.N.1    Jordan, B.A.2
  • 42
    • 0031913789 scopus 로고    scopus 로고
    • Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws
    • Heidemann W, Gerlach KL, Gröbel K-H, Köllner H-G. Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws. J Craniomaxillofac Surg 1998;26:50-55
    • (1998) J. Craniomaxillofac. Surg. , vol.26 , pp. 50-55
    • Heidemann, W.1    Gerlach, K.L.2    Gröbel, K.-H.3    Köllner, H.-G.4
  • 43
    • 0029917639 scopus 로고    scopus 로고
    • Experimental analysis of internal rigid fixation osteosynthesis performed with titanium bone screw and plate systems
    • Righi E, Carta M, Bruzzone AA, Lonardo PM, Marinaro E Pastorino A. Experimental analysis of internal rigid fixation osteosynthesis performed with titanium bone screw and plate systems. J Craniomaxillofac Surg 1996;24:53-57
    • (1996) J. Craniomaxillofac. Surg. , vol.24 , pp. 53-57
    • Righi, E.1    Carta, M.2    Bruzzone, A.A.3    Lonardo, P.M.4    Marinaro, E.5    Pastorino, A.6
  • 44
    • 0029904068 scopus 로고    scopus 로고
    • Die elastische Plattenosteosynthese, ihre Biomechanik, Indikation und Technik im Vergleich zur rigiden Ostsosynthese
    • Sturmer KM. Die elastische Plattenosteosynthese, ihre Biomechanik, Indikation und Technik im Vergleich zur rigiden Ostsosynthese. Unfallchirurg 1996;99:816-829
    • (1996) Unfallchirurg , vol.99 , pp. 816-829
    • Sturmer, K.M.1
  • 45
    • 0035704172 scopus 로고    scopus 로고
    • Force transfer between the plate and the bone: Relative importance of the bending stiffness of the screws friction between plate and bone
    • Cordey J, Borgeaud M, Perren SM. Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury 2000;31: Suppl 3: C21-C28
    • (2000) Injury , vol.31 , Issue.SUPPL. 3
    • Cordey, J.1    Borgeaud, M.2    Perren, S.M.3
  • 46
    • 0032052879 scopus 로고    scopus 로고
    • The influence of screw torque, object radius of curvature, mode of bone plate application and bone plate design on bone plate interface mechanics
    • Field JR, Hearn TC, Caldwell CB. The influence of screw torque, object radius of curvature, mode of bone plate application and bone plate design on bone plate interface mechanics. Injury 1998;29:233-241
    • (1998) Injury , vol.29 , pp. 233-241
    • Field, J.R.1    Hearn, T.C.2    Caldwell, C.B.3
  • 47
    • 0018769760 scopus 로고
    • Importance de la friction plaque-os pour l'ancrage des plaques d'ostéosynthèse. Détermitination du coefficient de friction métal-os chez l'animal 'in vivo'
    • Cordey J, Mikuschka-Galgoczy E, Blümlein H, Schneider U, Perren SM. Importance de la friction plaque-os pour l'ancrage des plaques d'ostéosynthèse. Détermitination du coefficient de friction métal-os chez l'animal 'in vivo'. Helv Chir Acta 1979; 46:183-187
    • (1979) Helv. Chir. Acta , vol.46 , pp. 183-187
    • Cordey, J.1    Mikuschka-Galgoczy, E.2    Blümlein, H.3    Schneider, U.4    Perren, S.M.5
  • 48
    • 0024632338 scopus 로고
    • Relationships between size, position, and angulation of human jaw muscles and unilateral first molar bite force
    • Sasaki K, Hannam AG, Wood WW. Relationships between size, position, and angulation of human jaw muscles and unilateral first molar bite force. J Dent Res 1989;68:499-503
    • (1989) J. Dent. Res. , vol.68 , pp. 499-503
    • Sasaki, K.1    Hannam, A.G.2    Wood, W.W.3
  • 50
    • 0034017138 scopus 로고    scopus 로고
    • Morphologic and biomechanical correlates with maximum bite forces in orthognathic surgery patients
    • Throckmorton GS, Ellis E 3rd, Buschang PH. Morphologic and biomechanical correlates with maximum bite forces in orthognathic surgery patients. J Oral Maxillofac Surg 2000;58:515-524
    • (2000) J. Oral Maxillofac. Surg. , vol.58 , pp. 515-524
    • Throckmorton, G.S.1    Ellis E. III2    Buschang, P.H.3
  • 51
    • 0032159057 scopus 로고    scopus 로고
    • The variability of bite force measurement between sessions, in different positions within the dental arch
    • Tortopidis D, Lyons MF, Baxendale RH, Gilmour WH. The variability of bite force measurement between sessions, in different positions within the dental arch. J Oral Rehabil 1998;25: 681-686
    • (1998) J. Oral Rehabil. , vol.25 , pp. 681-686
    • Tortopidis, D.1    Lyons, M.F.2    Baxendale, R.H.3    Gilmour, W.H.4
  • 52
    • 0033139585 scopus 로고    scopus 로고
    • Bite force and occlusal load distribution in normal complete dentition of young adults
    • Shinogaya T, Sodeyama A, Matsumoto M. Bite force and occlusal load distribution in normal complete dentition of young adults. Eur J Prosthodont Restor Dent 1999;7:65-70
    • (1999) Eur. J. Prosthodont. Restor. Dent. , vol.7 , pp. 65-70
    • Shinogaya, T.1    Sodeyama, A.2    Matsumoto, M.3
  • 53
    • 0034116614 scopus 로고    scopus 로고
    • Measure of bite force and occlusal contact area before and after bilateral sagittal split ramus osteotomy of the mandible using a new pressure-sensitive device: A preliminary report
    • Harada K, Watanabe M, Ohkura K, Enomoto S. Measure of bite force and occlusal contact area before and after bilateral sagittal split ramus osteotomy of the mandible using a new pressure-sensitive device: a preliminary report. J Oral Maxillofac Surg 2000;58:370-373
    • (2000) J. Oral Maxillofac. Surg. , vol.58 , pp. 370-373
    • Harada, K.1    Watanabe, M.2    Ohkura, K.3    Enomoto, S.4
  • 54
    • 0033506539 scopus 로고    scopus 로고
    • Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible
    • Maurer P, Holweg S, Schubert J. Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible. J Craniomaxillofac Surg 1999;27:365-372
    • (1999) J. Craniomaxillofac. Surg. , vol.27 , pp. 365-372
    • Maurer, P.1    Holweg, S.2    Schubert, J.3
  • 55
    • 0022456396 scopus 로고
    • Torque measurements of the mechanical load capacity of thin bony structures of the visceral cranium
    • Drommer RB. Torque measurements of the mechanical load capacity of thin bony structures of the visceral cranium. J Maxillofac Surg 1986;14:128-131
    • (1986) J. Maxillofac. Surg. , vol.14 , pp. 128-131
    • Drommer, R.B.1
  • 56
    • 0030666478 scopus 로고    scopus 로고
    • Screw osteosyntheisis compared with wire osteosynthesis in advancement genioplasty: A retrospective study of skeletal stability
    • Reyneke JP, Johnston T, van der Linden WJ. Screw osteosyntheisis compared with wire osteosynthesis in advancement genioplasty: a retrospective study of skeletal stability. Br J Oral Maxillofac Surg 1997;35:352-356
    • (1997) Br. J. Oral Maxillofac. Surg. , vol.35 , pp. 352-356
    • Reyneke, J.P.1    Johnston, T.2    van der Linden, W.J.3
  • 58
    • 0029693614 scopus 로고    scopus 로고
    • Experimental studies of the biomechanical stability of different miniplate configurations for the mandibular angle
    • Schierle HP, Schmelzeisen R, Rahn B. Experimental studies of the biomechanical stability of different miniplate configurations for the mandibular angle. Fortschr Kiefer Gesichtschir 1996;41:166-170
    • (1996) Fortschr. Kiefer Gesichtschir. , vol.41 , pp. 166-170
    • Schierle, H.P.1    Schmelzeisen, R.2    Rahn, B.3
  • 59
    • 0032775263 scopus 로고    scopus 로고
    • A computer study of fracture mobility and strain on biodegradable plates used for fixation of mandibular fractures
    • Tams J, Otten B, van Loon JP, Bos RR. A computer study of fracture mobility and strain on biodegradable plates used for fixation of mandibular fractures. J Oral Maxillofac Surg 1999; 57:973-981
    • (1999) J. Oral Maxillofac. Surg. , vol.57 , pp. 973-981
    • Tams, J.1    Otten, B.2    van Loon, J.P.3    Bos, R.R.4
  • 61
    • 0023074463 scopus 로고
    • Vorgeformte Titanosteosyntheseplatte für Kieferwinkelfrakturen
    • Heinl Th, Neumayer B. Vorgeformte Titanosteosyntheseplatte für Kieferwinkelfrakturen. Schweiz Monatschr Zahnmed 1987;97:985
    • (1987) Schweiz Monatschr. Zahnmed. , vol.97 , pp. 985
    • Heinl, Th.1    Neumayer, B.2
  • 62
    • 0033016299 scopus 로고    scopus 로고
    • An in vitro comparison of the effect of number and pattern of positional screws on load resistance
    • Haug RH, Barber JE, Punjabi AP. An in vitro comparison of the effect of number and pattern of positional screws on load resistance. J Oral Maxillofac Surg 1999;57:300-308
    • (1999) J. Oral Maxillofac. Surg. , vol.57 , pp. 300-308
    • Haug, R.H.1    Barber, J.E.2    Punjabi, A.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.