Volumn 29, Issue 3, 1998, Pages 233-241

The influence of screw torque, object radius of curvature, mode of bone plate application and bone plate design on bone-plate interface mechanics

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; COMPUTER ANALYSIS; PRIORITY JOURNAL; TORQUE;

EID: 0032052879     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0020-1383(98)00001-1     Document Type: Article
Times cited : (14)

References (20)
  • 2
    • 0025202404 scopus 로고
    • The limited contact dynamic compression plate (LC-DCP)
    • 2 Perren S. M., Klaue K. and Pohler O. etal. The limited contact dynamic compression plate (LC-DCP). Arch Orthop. Trauma Surg. 1990; 109: 304.
    • (1990) Arch Orthop. Trauma Surg. , vol.109 , pp. 304
    • Perren, S.M.1    Klaue, K.2    Pohler, O.3
  • 3
    • 0003067565 scopus 로고
    • Clinical aspects of 'bio-logical' plating
    • 3 Ganz R., Mast J., Weber B. G. et al. Clinical aspects of 'bio-logical' plating. Injury 1991; 22: 4.
    • (1991) Injury , vol.22 , pp. 4
    • Ganz, R.1    Mast, J.2    Weber, B.G.3
  • 4
    • 0029248968 scopus 로고
    • A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate and the point contact fixator
    • 4 Miclau T., Remiger A. and Tepic S. etal. A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate and the point contact fixator. J. Orthop. Res. 1995; 9: 170.
    • (1995) J. Orthop. Res. , vol.9 , pp. 170
    • Miclau, T.1    Remiger, A.2    Tepic, S.3
  • 5
    • 0019394993 scopus 로고
    • Effects of plates on cortical bone perfusion
    • 5 Jacobs R. R., Rahn B. A. and Perren S. M. Effects of plates on cortical bone perfusion. J. Trauma. 1981; 21: 910.
    • (1981) J. Trauma. , vol.21 , pp. 910
    • Jacobs, R.R.1    Rahn, B.A.2    Perren, S.M.3
  • 6
    • 0010479403 scopus 로고
    • Relationship between plate-bone contact area and blood supply in internal fixation
    • 6 Luethi U., Dueland T. and Rahn B. A. Relationship between plate-bone contact area and blood supply in internal fixation. J. Biomech. 1980; 13: 779.
    • (1980) J. Biomech. , vol.13 , pp. 779
    • Luethi, U.1    Dueland, T.2    Rahn, B.A.3
  • 7
    • 0023809603 scopus 로고
    • Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not stress protection?
    • 7 Perren S. M., Cordey J., Rahn B. A. et al. Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not stress protection? Clin. Orthop. Rel. Res. 1988; 232: 139.
    • (1988) Clin. Orthop. Rel. Res. , vol.232 , pp. 139
    • Perren, S.M.1    Cordey, J.2    Rahn, B.A.3
  • 8
    • 0002853165 scopus 로고
    • Porosity and remodelling of plated bone after internal fixation: Results of stress shielding or vascular damage
    • Louvain, Belgium
    • 8 Gautier E., Cordey J., Mathys R. et al. Porosity and remodelling of plated bone after internal fixation: results of stress shielding or vascular damage. Proceedings of the 4th European Conference on Biomaterials, Louvain, Belgium, 1983, p. 195.
    • (1983) Proceedings of the 4th European Conference on Biomaterials , pp. 195
    • Gautier, E.1    Cordey, J.2    Mathys, R.3
  • 9
    • 0002244310 scopus 로고
    • Effect of different plates on internal and external remodelling of intact long bones
    • New Orleans, Louisianna
    • 9 Gautier E., Rahn B. A., Perren S. M. Effect of different plates on internal and external remodelling of intact long bones. Proceedings 32nd ORS, New Orleans, Louisianna, 1986, p. 322.
    • (1986) Proceedings 32nd ORS , pp. 322
    • Gautier, E.1    Rahn, B.A.2    Perren, S.M.3
  • 10
    • 0025203230 scopus 로고
    • Clinical experience with titanium implants, especially with the limited contact dynamic compression plate
    • 10 Matter P. and Burch H. B. Clinical experience with titanium implants, especially with the limited contact dynamic compression plate. Arch. Orthop. Traum. Surg. 1990; 109: 311.
    • (1990) Arch. Orthop. Traum. Surg. , vol.109 , pp. 311
    • Matter, P.1    Burch, H.B.2
  • 12
    • 0024811571 scopus 로고
    • Stress shielding reduced by a silicone plate-bone interface. A canine experiment
    • 12 Korvick D. L., Newbrey J. W. and Bagby G. W. Stress shielding reduced by a silicone plate-bone interface. A canine experiment. Acta Orthop. Scand. 1989; 60: 611.
    • (1989) Acta Orthop. Scand. , vol.60 , pp. 611
    • Korvick, D.L.1    Newbrey, J.W.2    Bagby, G.W.3
  • 13
    • 0029339689 scopus 로고
    • Contact area and static pressure profile at the plate-bone interface in non-luted and luted bone plates
    • 13 Staller G. S., Richardson D. W. and Nunnamaker D. M. Contact area and static pressure profile at the plate-bone interface in non-luted and luted bone plates. Vet. Surg. 1995; 24: 299.
    • (1995) Vet. Surg. , vol.24 , pp. 299
    • Staller, G.S.1    Richardson, D.W.2    Nunnamaker, D.M.3
  • 14
    • 0031179597 scopus 로고    scopus 로고
    • Bone plate fixation: An evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact-dynamic compression plate (LC-DCP) in cadaveric bone
    • 14 Field J. R., Hearn T. C., Caldwell C. B. Bone plate fixation: an evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact-dynamic compression plate (LC-DCP) in cadaveric bone. J. Orthop. Trauma 1997; 11: 368-373.
    • (1997) J. Orthop. Trauma , vol.11 , pp. 368-373
    • Field, J.R.1    Hearn, T.C.2    Caldwell, C.B.3
  • 15
    • 0001962062 scopus 로고
    • Calibration and manipulation of data from Fuji pressure-sensitive film
    • ed. E. G. Little. Elsevier, Amsterdam
    • 15 Liggins A. B., Stranart J. C. E., Finlay J. B. et al. Calibration and manipulation of data from Fuji pressure-sensitive film. In Experimental Mechanics, ed. E. G. Little. Elsevier, Amsterdam, 1991, p. 61.
    • (1991) Experimental Mechanics , pp. 61
    • Liggins, A.B.1    Stranart, J.C.E.2    Finlay, J.B.3
  • 16
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • 16 Landis R. J. and Koch G. G. The measurement of observer agreement for categorical data. Biometrics 1977; 33: 159.
    • (1977) Biometrics , vol.33 , pp. 159
    • Landis, R.J.1    Koch, G.G.2
  • 17
    • 0000783769 scopus 로고
    • Morphological effect on bone with standard and experimental plate conformations
    • New Orleans, Louisianna
    • 17 Dueland R., Rahn B. A., Perren S. M. et al. Morphological effect on bone with standard and experimental plate conformations. In Proceedings 32nd ORS, New Orleans, Louisianna, 1986, p. 323.
    • (1986) Proceedings 32nd ORS , pp. 323
    • Dueland, R.1    Rahn, B.A.2    Perren, S.M.3
  • 18
    • 0026133837 scopus 로고
    • Effect of circumferential bands on cortical vascularity and viability
    • 18 Kirby B. M. and Wilson J. W. Effect of circumferential bands on cortical vascularity and viability. J. Orthop. Res. 1991; 9: 174.
    • (1991) J. Orthop. Res. , vol.9 , pp. 174
    • Kirby, B.M.1    Wilson, J.W.2
  • 19
    • 0014299919 scopus 로고
    • The normal microcirculation of diaphyseal cortex and its response to fracture
    • 19 Rhinelander F. W. The normal microcirculation of diaphyseal cortex and its response to fracture. J. Bone Joint Surg. 1968; 50-A: 784-800.
    • (1968) J. Bone Joint Surg. , vol.50 A , pp. 784-800
    • Rhinelander, F.W.1
  • 20
    • 0025454632 scopus 로고
    • The effect of fracture fixation on cortical bone blood flow
    • 20 Smith S. R., Bronk J. T. and Kelly P. J. The effect of fracture fixation on cortical bone blood flow. J. Orthop. Res. 1990; 8: 471.
    • (1990) J. Orthop. Res. , vol.8 , pp. 471
    • Smith, S.R.1    Bronk, J.T.2    Kelly, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.