메뉴 건너뛰기




Volumn 43, Issue 5, 2003, Pages 362-366

Flat-screen detector systems in skeletal radiology;Flachbilddetektorsysteme in der skelettradiologie

Author keywords

Bone radiographs; Diagnostic quality; Flat panel detectors; Radiation exposure; Workflow

Indexed keywords

CESIUM; IODIDE; PHOSPHORUS; SILICON;

EID: 0038457606     PISSN: 0033832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00117-003-0895-6     Document Type: Review
Times cited : (3)

References (21)
  • 1
    • 0035560182 scopus 로고    scopus 로고
    • Image quality vs radiation dose for flat-panel amorphous silicon detector: A phantom study
    • Geijer H, Beckmann KW, Andersson B, Persilden J (2001) Image quality vs radiation dose for flat-panel amorphous silicon detector: a phantom study. Eur Radiol 11(9):1704-1709
    • (2001) Eur Radiol , vol.11 , Issue.9 , pp. 1704-1709
    • Geijer, H.1    Beckmann, K.W.2    Andersson, B.3    Persilden, J.4
  • 2
    • 0036435962 scopus 로고    scopus 로고
    • Festkörperdetektorsysteme in der skelettradiologie
    • Grampp S (2002) Festkörperdetektorsysteme in der Skelettradiologie. Wien Med Wochenschr 152:12-14
    • (2002) Wien Med Wochenschr , vol.152 , pp. 12-14
    • Grampp, S.1
  • 3
    • 0034838887 scopus 로고    scopus 로고
    • Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography observer preference in clinical skeletal diagnostics
    • Hamers S, Freyschmidt J, Neitzel U (2001) Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography observer preference in clinical skeletal diagnostics. Eur Radiol 11:1753-1759
    • (2001) Eur Radiol , vol.11 , pp. 1753-1759
    • Hamers, S.1    Freyschmidt, J.2    Neitzel, U.3
  • 4
    • 0038213306 scopus 로고    scopus 로고
    • Diagnostic quality of digital and conventional radiographs in the assessment of DJD at the spine and knee
    • European Society of Musculoskeletal Radiology
    • Krestan C, Grampp, Heiner L, Eisenhuber E, Imhof H (2002) Diagnostic quality of digital and conventional radiographs in the assessment of DJD at the spine and knee. Abstract book, 9th annual meeting, European Society of Musculoskeletal Radiology, p 143
    • (2002) Abstract Book, 9th Annual Meeting , pp. 143
    • Krestan, C.1    Grampp2    Heiner, L.3    Eisenhuber, E.4    Imhof, H.5
  • 7
    • 0036153992 scopus 로고    scopus 로고
    • Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    • Ludwig K, Lenzen H, Kamm KF, Link TM, Diederich S, Wormann D, Heindel W (2002) Performance of a flat-panel detector in detecting artificial bone lesions: comparison with conventional screen-film and storage-phosphor radiography. Radiology 222(2):453-459
    • (2002) Radiology , vol.222 , Issue.2 , pp. 453-459
    • Ludwig, K.1    Lenzen, H.2    Kamm, K.F.3    Link, T.M.4    Diederich, S.5    Wormann, D.6    Heindel, W.7
  • 8
    • 0033625278 scopus 로고    scopus 로고
    • Impact of digital radiography on clinical workflow
    • May GA, Deer DD, Dackiewicz D (2000) Impact of digital radiography on clinical workflow. J Digit Imaging 13(2) [suppl 1]:76-78
    • (2000) J Digit Imaging , vol.13 , Issue.2 SUPPL. 1 , pp. 76-78
    • May, G.A.1    Deer, D.D.2    Dackiewicz, D.3
  • 9
    • 0026557314 scopus 로고
    • Computed radiography in musculoskeletal imaging: State of the art
    • Murphey MD, Quale JL, Martin NL et al. (1992) Computed radiography in musculoskeletal imaging: state of the art. AJR 158:19-27
    • (1992) AJR , vol.158 , pp. 19-27
    • Murphey, M.D.1    Quale, J.L.2    Martin, N.L.3
  • 10
    • 0036633683 scopus 로고    scopus 로고
    • Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    • Okamura T, Tanaka S, Koyama K, Norihumi N, Daikokuya H, Matsuoka T, Kishimoto K, Hatagawa M, Kudoh H, Yamada R (2002) Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen. Eur Radiol 12(4):1741-1747
    • (2002) Eur Radiol , vol.12 , Issue.4 , pp. 1741-1747
    • Okamura, T.1    Tanaka, S.2    Koyama, K.3    Norihumi, N.4    Daikokuya, H.5    Matsuoka, T.6    Kishimoto, K.7    Hatagawa, M.8    Kudoh, H.9    Yamada, R.10
  • 11
    • 0035263307 scopus 로고    scopus 로고
    • Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images
    • Peer S, Neitzel U, Giacomuzzi SM, Peer R, Gassner E, Steingruber I, Jaschke W (2001) Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images. IEEETrans Med Imaging 20(3):239-242
    • (2001) IEEETrans Med Imaging , vol.20 , Issue.3 , pp. 239-242
    • Peer, S.1    Neitzel, U.2    Giacomuzzi, S.M.3    Peer, R.4    Gassner, E.5    Steingruber, I.6    Jaschke, W.7
  • 13
    • 0033180541 scopus 로고    scopus 로고
    • Flat panel detectors - Closing the (digital) gap in chest and skeletal radiology
    • Reif KJ (1999) Flat panel detectors - closing the (digital) gap in chest and skeletal radiology. Eur J Radiol 31(2):125-131
    • (1999) Eur J Radiol , vol.31 , Issue.2 , pp. 125-131
    • Reif, K.J.1
  • 14
    • 0035190161 scopus 로고    scopus 로고
    • Erste klinische erfahrungen mit einem grossformatigen flächendetektorsystem bei aufnahmen des peripheren skelettsystems
    • Reissberg S, Hoeschen C, Kästner A, Theus U, Fiedler R, Krause U, Döhring W (2001) Erste klinische Erfahrungen mit einem grossformatigen Flächendetektorsystem bei Aufnahmen des peripheren Skelettsystems. Röfo 173:1048-1052
    • (2001) Röfo , vol.173 , pp. 1048-1052
    • Reissberg, S.1    Hoeschen, C.2    Kästner, A.3    Theus, U.4    Fiedler, R.5    Krause, U.6    Döhring, W.7
  • 15
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography system - A contrast-detail phantom study
    • Rong XJ, Shaw CC, Liu X, Lemacks MR, Thompson SK (2001) Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography system - a contrast-detail phantom study. Med Phys 28(11):2328-2335
    • (2001) Med Phys , vol.28 , Issue.11 , pp. 2328-2335
    • Rong, X.J.1    Shaw, C.C.2    Liu, X.3    Lemacks, M.R.4    Thompson, S.K.5
  • 16
    • 0031859116 scopus 로고    scopus 로고
    • Clinical application of a flat panel X-ray detector based on amorphous silicon technology: Image quality and potential for radiation dose reduction in skeletal radiography
    • Strotzer M, Gmeinwieser JK, Völk M (1998) Clinical application of a flat panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. AJR 171:23-27
    • (1998) AJR , vol.171 , pp. 23-27
    • Strotzer, M.1    Gmeinwieser, J.K.2    Völk, M.3
  • 17
    • 0031975442 scopus 로고    scopus 로고
    • Amorphous silicon, flat-panel, X-ray detector versus screen-film radiography. Effect of dose reduction on the detectability of cortical bone defects and fractures
    • Strotzer M, Gmeinwieser JK, Spahn M et al. (1998) Amorphous silicon, flat-panel, X-ray detector versus screen-film radiography. Effect of dose reduction on the detectability of cortical bone defects and fractures. Invest Radiol 33:33-38
    • (1998) Invest Radiol , vol.33 , pp. 33-38
    • Strotzer, M.1    Gmeinwieser, J.K.2    Spahn, M.3
  • 18
    • 0342264667 scopus 로고    scopus 로고
    • Simulated bone erosion in a hand phantom: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flatpanel detector
    • Strotzer M, Voelk M, Wild T et al. (2000) Simulated bone erosion in a hand phantom: detection with conventional screen-film technology versus cesium iodide-amorphous silicon flatpanel detector. Radiology 215:512-515
    • (2000) Radiology , vol.215 , pp. 512-515
    • Strotzer, M.1    Voelk, M.2    Wild, T.3
  • 19
    • 0036632163 scopus 로고    scopus 로고
    • Digital radiography with flatpanel detectors: The missing link
    • Strotzer M (2002) Digital radiography with flatpanel detectors: the missing link. Eur Radiol 12:1603-1604
    • (2002) Eur Radiol , vol.12 , pp. 1603-1604
    • Strotzer, M.1
  • 20
    • 0034522351 scopus 로고    scopus 로고
    • Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: Image quality and potential for dose reduction in comparison with screen-film radiography
    • Volk M, Strotzer M, Holzknecht N, Manke C, Lenhart M, Gmeinwieser J, Link J, Reiser M, Feuerbach S (2000) Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography. Clin Radiol 55(8):615-621
    • (2000) Clin Radiol , vol.55 , Issue.8 , pp. 615-621
    • Volk, M.1    Strotzer, M.2    Holzknecht, N.3    Manke, C.4    Lenhart, M.5    Gmeinwieser, J.6    Link, J.7    Reiser, M.8    Feuerbach, S.9
  • 21
    • 0035178468 scopus 로고    scopus 로고
    • Detection of porcine bone lesions and fissures: Comparing digital selenium, digital luminescence, and analog film-screen radiography
    • Zahringer M, Krug B, Kamm KF, Wassmer G, Hellmich M, Winnekendonk G, Andermahr J, Gossmann A, Lackner KJ (2001) Detection of porcine bone lesions and fissures: comparing digital selenium, digital luminescence, and analog film-screen radiography. AJR 177(6):1397-1403
    • (2001) AJR , vol.177 , Issue.6 , pp. 1397-1403
    • Zahringer, M.1    Krug, B.2    Kamm, K.F.3    Wassmer, G.4    Hellmich, M.5    Winnekendonk, G.6    Andermahr, J.7    Gossmann, A.8    Lackner, K.J.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.