메뉴 건너뛰기




Volumn 152, Issue SUPPL. 113, 2002, Pages 12-14

Flat panel detector systems in musculoskeletal radiology;Festkörperdetektorsysteme in der skelettradiologie

Author keywords

Diagnostic quality; Flatpanel detectors; Workflow

Indexed keywords

ARTICLE; BONE RADIOGRAPHY; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; FLAT PANEL DETECTOR; HUMAN; IMAGE QUALITY; MUSCULOSKELETAL DISEASE; RADIODIAGNOSIS; X RAY; BONE DISEASE; EQUIPMENT DESIGN; EVALUATION; HEALTH CARE QUALITY; HOSPITAL INFORMATION SYSTEM; INSTRUMENTATION; RADIOGRAPHY;

EID: 0036435962     PISSN: 00435341     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (9)
  • 1
    • 0034838887 scopus 로고    scopus 로고
    • Digital radiography with a large-scale electronic flat-panel detector vs. screen-film radiography observer preference in clinical skeletal diagnostics
    • Hamers S, Freyschmidt J, Neitzel U: Digital radiography with a large-scale electronic flat-panel detector vs. screen-film radiography observer preference in clinical skeletal diagnostics. Eur Radiol, 2001;11:1753-1759.
    • (2001) Eur Radiol , vol.11 , pp. 1753-1759
    • Hamers, S.1    Freyschmidt, J.2    Neitzel, U.3
  • 2
    • 0011662976 scopus 로고    scopus 로고
    • Flat-panel detector digital radiography versus conventional screen-film radiography: Diagnostic quality in degenerative joint disease
    • eingereicht
    • Heiner L, Grampp S, Krestan C, Eisenhuber E, Czerny, C, Imhof H: Flat-panel detector digital radiography versus conventional screen-film radiography: Diagnostic quality in degenerative joint disease. Eur Radiol. 2002 (eingereicht).
    • (2002) Eur Radiol
    • Heiner, L.1    Grampp, S.2    Krestan, C.3    Eisenhuber, E.4    Czerny, C.5    Imhof, H.6
  • 5
    • 0036633683 scopus 로고    scopus 로고
    • Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    • Okamura T, Tanaka S, Koyama K, Norihumi N, Daikokuya H, Matsuoka T, Kishimoto K, Hatagawa M, Kudoh H, Yamada R: Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen. Eur Radiol 2002;12:1741-1747.
    • (2002) Eur Radiol , vol.12 , pp. 1741-1747
    • Okamura, T.1    Tanaka, S.2    Koyama, K.3    Norihumi, N.4    Daikokuya, H.5    Matsuoka, T.6    Kishimoto, K.7    Hatagawa, M.8    Kudoh, H.9    Yamada, R.10
  • 6
    • 0031859116 scopus 로고    scopus 로고
    • Clinical application of a flat panel x-ray detector based on amorphous silicon technology: Image quality and potential for radiation dose reduction in skeletal radiography
    • Strotzer M, Gmeinwieser JK, Völk M: Clinical application of a flat panel x-ray detector based on amorphous silicon technology: Image quality and potential for radiation dose reduction in skeletal radiography. AJR 1998;171:23-27.
    • (1998) AJR , vol.171 , pp. 23-27
    • Strotzer, M.1    Gmeinwieser, J.K.2    Völk, M.3
  • 7
    • 0031975442 scopus 로고    scopus 로고
    • Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography. Effect of dose reduction on the detectability of cortical bone defects and fractures
    • Strotzer M, Gmeinwieser J, Spahn M, Volk M, Frund R, Seitz J, Spies V, Alexander J, Feuerbach S: Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography. Effect of dose reduction on the detectability of cortical bone defects and fractures. Invest Radiol 1998;33:33-38.
    • (1998) Invest Radiol , vol.33 , pp. 33-38
    • Strotzer, M.1    Gmeinwieser, J.2    Spahn, M.3    Volk, M.4    Frund, R.5    Seitz, J.6    Spies, V.7    Alexander, J.8    Feuerbach, S.9
  • 8
    • 0342264667 scopus 로고    scopus 로고
    • Simulated bone erosion in a hand phantom: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector
    • Strotzer M, Volk M, Wild T, von Landenberg P, Feuerbach S: Simulated bone erosion in a hand phantom: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector. Radiology 2000;215:512-515.
    • (2000) Radiology , vol.215 , pp. 512-515
    • Strotzer, M.1    Volk, M.2    Wild, T.3    Von Landenberg, P.4    Feuerbach, S.5
  • 9
    • 0036632163 scopus 로고    scopus 로고
    • Digital radiography with flat-panel detectors; the missing link
    • Strotzer M: Digital radiography with flat-panel detectors; the missing link. Eur Radiol 2002;12:1603-1604.
    • (2002) Eur Radiol , vol.12 , pp. 1603-1604
    • Strotzer, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.