메뉴 건너뛰기




Volumn 27, Issue SUPPL. 1, 2003, Pages

Long term results with the BiCONTACT system - Aspects to investigate and to learn from

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; BONE REGENERATION; CONFERENCE PAPER; DISEASE COURSE; ENDOPROSTHESIS LOOSENING; EVALUATION; FEMUR HEAD PROSTHESIS; FOLLOW UP; FRACTURE FIXATION; HIP DYSPLASIA; HIP INJURY; HIP PROSTHESIS; HUMAN; INFECTION; LONG TERM CARE; MAJOR CLINICAL STUDY; MATERIAL COATING; OSTEOARTHRITIS; PRIORITY JOURNAL; PROSTHESIS LOOSENING; PROSTHESIS MATERIAL; RECURRENT DISLOCATION; SCORING SYSTEM; SURVIVAL; TISSUE NECROSIS; TOTAL HIP PROSTHESIS;

EID: 0038348188     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-003-0435-z     Document Type: Conference Paper
Times cited : (23)

References (10)
  • 1
    • 0032797392 scopus 로고    scopus 로고
    • Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse-femoral component analysis
    • Biedermann R, Krismer M, Stöckl B, Mayrhofer P, Ornstein E, Franzen H (1999) Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse-femoral component analysis. J Bone Joint Surg [Br] 81:266-272
    • (1999) J Bone Joint Surg [Br] , vol.81 , pp. 266-272
    • Biedermann, R.1    Krismer, M.2    Stöckl, B.3    Mayrhofer, P.4    Ornstein, E.5    Franzen, H.6
  • 2
    • 0034919889 scopus 로고    scopus 로고
    • Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements
    • Biedermann R, Stöckl B, Krismer M, Mayrhofer P, Ornstein E, Franzen H (2001) Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses. A comparison of conventional measurements. J Bone Joint Surg [Br] 83:767-771
    • (2001) J Bone Joint Surg [Br] , vol.83 , pp. 767-771
    • Biedermann, R.1    Stöckl, B.2    Krismer, M.3    Mayrhofer, P.4    Ornstein, E.5    Franzen, H.6
  • 5
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 257:107-128
    • (1990) Clin Orthop , vol.257 , pp. 107-128
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 6
    • 0029380423 scopus 로고
    • EBRA: A method to measure migration of acetabular components
    • Krismer M, Bauer R, Tschupik J, Mayrhofer P. (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225-1236
    • (1995) J Biomech , vol.28 , pp. 1225-1236
    • Krismer, M.1    Bauer, R.2    Tschupik, J.3    Mayrhofer, P.4
  • 7
    • 0032805261 scopus 로고    scopus 로고
    • The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis
    • Krismer M, Biedermann R, Stöckl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg [Br] 81:273-280
    • (1999) J Bone Joint Surg [Br] , vol.81 , pp. 273-280
    • Krismer, M.1    Biedermann, R.2    Stöckl, B.3    Fischer, M.4    Bauer, R.5    Haid, C.6
  • 8
    • 0028892402 scopus 로고
    • Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients
    • Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418-424
    • (1995) Acta Orthop Scand , vol.66 , pp. 418-424
    • Malchau, H.1    Karrholm, J.2    Wang, Y.X.3    Herberts, P.4
  • 9
    • 0036941266 scopus 로고    scopus 로고
    • Press-fit stability of uncemented hemispheric acetabular components: A comparison of three porous coating systems
    • Markel DC, Hora N, Grimm M (2002) Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems. Int Orthop 26:72-75
    • (2002) Int Orthop , vol.26 , pp. 72-75
    • Markel, D.C.1    Hora, N.2    Grimm, M.3
  • 10
    • 0029047045 scopus 로고
    • Comparison of the results of cemented, porous in-growth and threaded acetabular cup fixation
    • Yahiro MA, Gantenberg JB, Nelson R, Lu HTC, Mishra NK (1995) Comparison of the results of cemented, porous in-growth and threaded acetabular cup fixation. J Arthroplasty 10:339-350
    • (1995) J Arthroplasty , vol.10 , pp. 339-350
    • Yahiro, M.A.1    Gantenberg, J.B.2    Nelson, R.3    Lu, H.T.C.4    Mishra, N.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.