Volumn 14, Issue 1, 2003, Pages 103-114

Mandibular flexure and stress build-up in mandibular full-arch fixed prostheses supported by osseointegrated implants

Author keywords

Finite element analysis; Mandibular flexure; Osseointegrated implants; Stress distribution

Indexed keywords

ARTICLE; BIOMECHANICS; BONE DEFORMATION; IMPLANT; MANDIBLE; MODEL; STRESS; TOOTH IMPLANTATION; BIOLOGICAL MODEL; BONE REGENERATION; CERAMICS; CHEMISTRY; COMPUTER SIMULATION; DENTURE; EDENTULOUSNESS; FINITE ELEMENT ANALYSIS; HUMAN; MECHANICAL STRESS; PATHOPHYSIOLOGY; PHYSIOLOGY; PLIABILITY; SURFACE PROPERTY; TOOTH PROSTHESIS; WEIGHT BEARING;

EID: 0038284246     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0501.2003.140114.x     Document Type: Article
Times cited : (87)

References (47)
  • 3
    • 0345279765 scopus 로고
    • Elasticity and viscoelasticity of cortical bone
    • Hastings, G.W. & Ducheyne, P., eds. Boca Raton, FL: CRC Press
    • Bonfield, W. (1984) Elasticity and viscoelasticity of cortical bone. In: Hastings, G.W. & Ducheyne, P., eds. Natural and living biomaterials, 43-60. Boca Raton, FL: CRC Press.
    • (1984) Natural and Living Biomaterials , pp. 43-60
    • Bonfield, W.1
  • 4
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Brånemark, P.-I. (1983) Osseointegration and its experimental background. Journal of Prosthetic Dentistry 50: 399-410.
    • (1983) Journal of Prosthetic Dentistry , vol.50 , pp. 399-410
    • Brånemark, P.-I.1
  • 7
    • 0015329575 scopus 로고
    • Patterns of change in human mandibular arch width during jaw excursions
    • Burch, J.G. (1972) Patterns of change in human mandibular arch width during jaw excursions. Archives of Oral Biology 17: 623-631.
    • (1972) Archives of Oral Biology , vol.17 , pp. 623-631
    • Burch, J.G.1
  • 10
  • 12
    • 0016966795 scopus 로고
    • The influence of fixed splints on mandibular flexure
    • Fischman, B. (1976) The influence of fixed splints on mandibular flexure. Journal of Prosthetic Dentistry 35: 643-647.
    • (1976) Journal of Prosthetic Dentistry , vol.35 , pp. 643-647
    • Fischman, B.1
  • 13
    • 0025499136 scopus 로고
    • The rotational aspect of mandibular flexure
    • Fischman, B. (1990) The rotational aspect of mandibular flexure. Journal of Prosthetic Dentistry 64: 483-485.
    • (1990) Journal of Prosthetic Dentistry , vol.64 , pp. 483-485
    • Fischman, B.1
  • 15
    • 0022746936 scopus 로고
    • Some aspects of mandibular movement: Acceleration and horizontal distortion
    • Grant, A.A. (1986) Some aspects of mandibular movement: Acceleration and horizontal distortion. Annals of the Academy of Medicine, Singapore 15: 305-310.
    • (1986) Annals of the Academy of Medicine, Singapore , vol.15 , pp. 305-310
    • Grant, A.A.1
  • 16
    • 0003221520 scopus 로고
    • Muscoloskeletal biomechanics in the human jaw
    • Zarb, G.A., Carlsson, G.E., Sessle, B.J. & Mohl, N.D., eds. Copenhagen: Munksgaard
    • Hannam, A.G. (1994) Muscoloskeletal biomechanics in the human jaw. In: Zarb, G.A., Carlsson, G.E., Sessle, B.J. & Mohl, N.D., eds. Temporo-mandibular joint and masticatory muscle disorders, 2nd edn, 114. Copenhagen: Munksgaard.
    • (1994) Temporo-mandibular Joint and Masticatory Muscle Disorders, 2nd Edn , pp. 114
    • Hannam, A.G.1
  • 18
    • 0345279764 scopus 로고
    • Gnathologic reconstruction for osseointegrated implants
    • Hobo, S. & Itoh, H. (1990) Gnathologic reconstruction for osseointegrated implants. Journal of Gnathology 9: 49-64.
    • (1990) Journal of Gnathology , vol.9 , pp. 49-64
    • Hobo, S.1    Itoh, H.2
  • 21
    • 0022854549 scopus 로고
    • Jaw movements and patterns of mandibular bone strain during mastication in the monkey Macaca fascicularis
    • Hylander, W.I. & Crompton, A.W. (1986) Jaw movements and patterns of mandibular bone strain during mastication in the monkey Macaca fascicularis. Archives of Oral Biology 31: 841-848.
    • (1986) Archives of Oral Biology , vol.31 , pp. 841-848
    • Hylander, W.I.1    Crompton, A.W.2
  • 22
    • 0023110052 scopus 로고
    • Loading patterns and jaw movements during mastication in Macaca fascicularis: A bone-strain, electromyographic, and cineradiographic analysis
    • Hylander, W.I., Johnson, K.R. & Crompton, A.W. (1987) Loading patterns and jaw movements during mastication in Macaca fascicularis: a bone-strain, electromyographic, and cineradiographic analysis. American Journal of Physical Anthropology 72: 287-314.
    • (1987) American Journal of Physical Anthropology , vol.72 , pp. 287-314
    • Hylander, W.I.1    Johnson, K.R.2    Crompton, A.W.3
  • 23
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • Isidor, F. (1996) Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clinical Oral Implants Research 7: 143-152.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 143-152
    • Isidor, F.1
  • 24
    • 0030097958 scopus 로고    scopus 로고
    • In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw
    • Jemt, T. (1996) In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. International Journal of Oral and Maxillofacial Implants 11: 151-158.
    • (1996) International Journal of Oral and Maxillofacial Implants , vol.11 , pp. 151-158
    • Jemt, T.1
  • 25
    • 0344416891 scopus 로고
    • Uber die reaktionen des gebisses auf gaumenplatten
    • Jung, F. (1957) Uber die reaktionen des gebisses auf gaumenplatten. Deutsche Zahnarztliche Zeitschrift 12: 688-695.
    • (1957) Deutsche Zahnarztliche Zeitschrift , vol.12 , pp. 688-695
    • Jung, F.1
  • 26
    • 0344416890 scopus 로고
    • Veranderungen des prothesenlagers unter der teilprothese
    • Jung, F. (1959) Veranderungen des prothesenlagers unter der teilprothese. Deutsche Zahnarztliche Zeitschrift 14: 105-107.
    • (1959) Deutsche Zahnarztliche Zeitschrift , vol.14 , pp. 105-107
    • Jung, F.1
  • 27
    • 0345711376 scopus 로고
    • Die funktionellelastische deformation des kieferknochens und die eigenbeweglichkeit der zahne
    • Jung, F. (1960) Die funktionellelastische deformation des kieferknochens und die eigenbeweglichkeit der zahne. Schweizerische Monatsschrift Fur Zahnheilkunde 70: 17-30.
    • (1960) Schweizerische Monatsschrift fur Zahnheilkunde , vol.70 , pp. 17-30
    • Jung, F.1
  • 28
  • 29
    • 0013584415 scopus 로고    scopus 로고
    • Simulated physics of the human mandible
    • Mcneill C., ed. Chicago: Quintessence Publishing Co.
    • Korioth, T.W.P. (1997) Simulated physics of the human mandible. In: Mcneill C., ed. Science and practice of occlusion, 1st edn, 179-186. Chicago: Quintessence Publishing Co.
    • (1997) Science and Practice of Occlusion, 1st Edn , pp. 179-186
    • Korioth, T.W.P.1
  • 30
    • 0028026551 scopus 로고
    • Deformation of the human mandible during simulated tooth clenching
    • Korioth, T.W.P. & Hannam, A.G. (1994) Deformation of the human mandible during simulated tooth clenching. Journal of Dental Research 73: 56-66.
    • (1994) Journal of Dental Research , vol.73 , pp. 56-66
    • Korioth, T.W.P.1    Hannam, A.G.2
  • 31
    • 0023516779 scopus 로고
    • Functional strain in bone tissue as an objective, and a controlling stimulus for adaptive bone remodelling
    • Lanyon, L.E. (1987) Functional strain in bone tissue as an objective, and a controlling stimulus for adaptive bone remodelling. Journal of Biomechanics 20: 1083-1093.
    • (1987) Journal of Biomechanics , vol.20 , pp. 1083-1093
    • Lanyon, L.E.1
  • 32
    • 0023672133 scopus 로고
    • Bone resorption around fixture in edentulous patients treated with mandibular fixed tissue-integrated prosthesis
    • Lindquist, L., Rockler, B. & Carlson, G. (1988) Bone resorption around fixture in edentulous patients treated with mandibular fixed tissue-integrated prosthesis. Journal of Prosthetic Dentistry 59: 59-63.
    • (1988) Journal of Prosthetic Dentistry , vol.59 , pp. 59-63
    • Lindquist, L.1    Rockler, B.2    Carlson, G.3
  • 33
    • 0026955741 scopus 로고
    • Cantilever rests: An alternative to unsupported distal cantilever of osseointegrated implant-supported prostheses for the edentulous mandible
    • McCartney, J.W. (1992) Cantilever rests: an alternative to unsupported distal cantilever of osseointegrated implant-supported prostheses for the edentulous mandible. Journal of Prosthetic Dentistry 68: 817-819.
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 817-819
    • McCartney, J.W.1
  • 34
    • 84964191340 scopus 로고
    • A quantitative analysis of the decrease in width of the mandibular arch during forced movements of the mandible
    • McDowell, J.A. & Regli, C.P. (1961) A quantitative analysis of the decrease in width of the mandibular arch during forced movements of the mandible. Journal of Dental Research 40: 1183-1185.
    • (1961) Journal of Dental Research , vol.40 , pp. 1183-1185
    • McDowell, J.A.1    Regli, C.P.2
  • 35
    • 0027015903 scopus 로고
    • A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
    • Naert, I., Quirynen, M., Van Steenberghe, D. & Darius, D. (1992) A study of 589 consecutive implants supporting complete fixed prostheses. Part II: prosthetic aspects. Journal of Prosthetic Dentistry 68: 949-956.
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 949-956
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, D.4
  • 36
    • 0019497111 scopus 로고
    • Mandibular flexure associated with muscle force applied retruded axis position
    • Omar, R. & Wise, M.D. (1981) Mandibular flexure associated with muscle force applied retruded axis position. Journal of Oral Rehabilitation 8: 209-211.
    • (1981) Journal of Oral Rehabilitation , vol.8 , pp. 209-211
    • Omar, R.1    Wise, M.D.2
  • 37
    • 0142079725 scopus 로고
    • Medial convergence of the mandible
    • Osborne, J. & Tomlin, H.R. (1964) Medial convergence of the mandible. British Dental Journal 117: 112-114.
    • (1964) British Dental Journal , vol.117 , pp. 112-114
    • Osborne, J.1    Tomlin, H.R.2
  • 39
    • 0014039927 scopus 로고
    • The phenomenon of the decreased mandibular arch width in opening movements
    • Regli, C.P. & Kelly, E.K. (1967) The phenomenon of the decreased mandibular arch width in opening movements. Journal of Prosthetic Dentistry 17: 49-53.
    • (1967) Journal of Prosthetic Dentistry , vol.17 , pp. 49-53
    • Regli, C.P.1    Kelly, E.K.2
  • 42
    • 0030207323 scopus 로고    scopus 로고
    • Analysis of strain at selected bone sites of cantilevered implant-supported prosthesis
    • Tashkandi, E.A., Lang, B.R. & Edge, M.J. (1996) Analysis of strain at selected bone sites of cantilevered implant-supported prosthesis. Journal of Prosthetic Dentistry 76: 158-164.
    • (1996) Journal of Prosthetic Dentistry , vol.76 , pp. 158-164
    • Tashkandi, E.A.1    Lang, B.R.2    Edge, M.J.3
  • 43
    • 0030147360 scopus 로고    scopus 로고
    • Factors affecting crestal bone loss with dental implants partially covered with a porous coating: A finite element analysis
    • Vaillancourt, H., Pilliar, R.M. & McCammond, D. (1996) Factors affecting crestal bone loss with dental implants partially covered with a porous coating: a finite element analysis. International Journal of Oral and Maxillofacial Implants 11: 351-359.
    • (1996) International Journal of Oral and Maxillofacial Implants , vol.11 , pp. 351-359
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 44
    • 0029175465 scopus 로고
    • Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses
    • Van Zyl, P.P., Grundling, N.L., Jooste, C.H. & Terblanche, E. (1995) Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. International Journal of Oral and Maxillofacial Implants 10: 51-57.
    • (1995) International Journal of Oral and Maxillofacial Implants , vol.10 , pp. 51-57
    • Van Zyl, P.P.1    Grundling, N.L.2    Jooste, C.H.3    Terblanche, E.4
  • 45
    • 0018239819 scopus 로고
    • The influence that bone density and the orientation and particle's size of the mineral phase have on the mechanical properties of bone
    • Wall, J.C., Chatterji, S.K. & Jeffery, J.W. (1978) The influence that bone density and the orientation and particle's size of the mineral phase have on the mechanical properties of bone. Journal of Bioengineering 2: 517-526.
    • (1978) Journal of Bioengineering , vol.2 , pp. 517-526
    • Wall, J.C.1    Chatterji, S.K.2    Jeffery, J.W.3
  • 46
    • 0027613203 scopus 로고
    • Endosseous titanium implants during and after orthodontic load: An experimental study in the dog
    • Wehrbein, H. & Diedrich, P. (1993) Endosseous titanium implants during and after orthodontic load: an experimental study in the dog. Clinical Oral Implants Research 4: 76-82.
    • (1993) Clinical Oral Implants Research , vol.4 , pp. 76-82
    • Wehrbein, H.1    Diedrich, P.2
  • 47
    • 0028435430 scopus 로고
    • Effect of cantilever length on stress transfer by implant-supported prostheses
    • White, S.N., Caputo, A.A. & Anderkvist, T. (1994) Effect of cantilever length on stress transfer by implant-supported prostheses. Journal of Prosthetic Dentistry 71: 493-499.
    • (1994) Journal of Prosthetic Dentistry , vol.71 , pp. 493-499
    • White, S.N.1    Caputo, A.A.2    Anderkvist, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.