메뉴 건너뛰기




Volumn 92, Issue 1-2, 2003, Pages 232-239

Discrimination among milks and cultured dairy products using screen-printed electrochemical arrays and an electronic nose

Author keywords

Dairy; Electrochemical arrays; Multivariate analysis; Screen printing

Indexed keywords

DAIRY PRODUCTS; ELECTROCHEMISTRY; REDOX REACTIONS; SCREEN PRINTING; SENSITIVITY ANALYSIS;

EID: 0038248832     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(03)00271-5     Document Type: Article
Times cited : (48)

References (29)
  • 1
  • 2
    • 0025708295 scopus 로고
    • Coated amperometric electrode arrays for multicomponent analysis
    • Wang J., Rayson G.D., Lu Z., Wu H. Coated amperometric electrode arrays for multicomponent analysis. Anal. Chem. 62:1990;1924-1927.
    • (1990) Anal. Chem. , vol.62 , pp. 1924-1927
    • Wang, J.1    Rayson, G.D.2    Lu, Z.3    Wu, H.4
  • 3
    • 0000005092 scopus 로고
    • Sensor array for carbohydrates and amino acids based on electrocatalytic modified electrodes
    • Chen C., Wang J., Rayson G., Tian B., Lin Y. Sensor array for carbohydrates and amino acids based on electrocatalytic modified electrodes. Anal. Chem. 65:1993;251-254.
    • (1993) Anal. Chem. , vol.65 , pp. 251-254
    • Chen, C.1    Wang, J.2    Rayson, G.3    Tian, B.4    Lin, Y.5
  • 4
    • 0035368283 scopus 로고    scopus 로고
    • Compression of electronic tongue data based on voltammetry - A comparative study
    • Holmin S., Spangeus P., Krantz-Rulcker C., Winquist F. Compression of electronic tongue data based on voltammetry - a comparative study. Sens. Actuators B. 76:2001;455-464.
    • (2001) Sens. Actuators B , vol.76 , pp. 455-464
    • Holmin, S.1    Spangeus, P.2    Krantz-Rulcker, C.3    Winquist, F.4
  • 5
    • 0035369428 scopus 로고    scopus 로고
    • Discrimination of tea by means of a voltammetric electronic tongue and different applied waveforms
    • Ivarsson P., Homin S., Hojer N.E., Krantz-Rulcker C., Winquist F. Discrimination of tea by means of a voltammetric electronic tongue and different applied waveforms. Sens. Actuators B. 76:2001;449-454.
    • (2001) Sens. Actuators B , vol.76 , pp. 449-454
    • Ivarsson, P.1    Homin, S.2    Hojer, N.E.3    Krantz-Rulcker, C.4    Winquist, F.5
  • 8
    • 0032296936 scopus 로고    scopus 로고
    • Monitoring of fresh milk by an electronic tongue on the basis of voltammetry
    • Winquist F., Krantz-Rulcker C., Wide P., Lundstrom I. Monitoring of fresh milk by an electronic tongue on the basis of voltammetry. Meas. Sci. Technol. 9:1998;1937-1946.
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 1937-1946
    • Winquist, F.1    Krantz-Rulcker, C.2    Wide, P.3    Lundstrom, I.4
  • 9
    • 0342757597 scopus 로고    scopus 로고
    • The combination of an electronic tongue and an electronic nose
    • Winquist F., Lundstrom I., Wide P. The combination of an electronic tongue and an electronic nose. Sens. Actuators B. 58:1999;512-517.
    • (1999) Sens. Actuators B , vol.58 , pp. 512-517
    • Winquist, F.1    Lundstrom, I.2    Wide, P.3
  • 11
    • 0027474192 scopus 로고
    • Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase
    • Cardosi M.F., Birch S.W. Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase. Anal. Chim. Acta. 276:1993;69-74.
    • (1993) Anal. Chim. Acta , vol.276 , pp. 69-74
    • Cardosi, M.F.1    Birch, S.W.2
  • 12
    • 0343022327 scopus 로고    scopus 로고
    • Flexible amperometric transducers for biosensors based on a screen-printed three electrode system
    • Erlenkotter A., Kottbus M., Chemnitius G.C. Flexible amperometric transducers for biosensors based on a screen-printed three electrode system. J. Electroanal. Chem. 481:2000;82-94.
    • (2000) J. Electroanal. Chem. , vol.481 , pp. 82-94
    • Erlenkotter, A.1    Kottbus, M.2    Chemnitius, G.C.3
  • 13
    • 0034950479 scopus 로고    scopus 로고
    • Physical characterization of a screen-printed electrode for use in an amperometric biosensor system
    • Grennan K., Killard A.J., Smyth M.R. Physical characterization of a screen-printed electrode for use in an amperometric biosensor system. Electroanalysis. 13:2001;745-750.
    • (2001) Electroanalysis , vol.13 , pp. 745-750
    • Grennan, K.1    Killard, A.J.2    Smyth, M.R.3
  • 14
    • 0032584563 scopus 로고    scopus 로고
    • Assessment of glucose behaviour in alcoholic solutions using disposable electrodes
    • Kroger S., Setford S.J., Turner A.P.F. Assessment of glucose behaviour in alcoholic solutions using disposable electrodes. Anal. Chim. Acta. 368:1998;219-231.
    • (1998) Anal. Chim. Acta , vol.368 , pp. 219-231
    • Kroger, S.1    Setford, S.J.2    Turner, A.P.F.3
  • 15
    • 0000310864 scopus 로고
    • Catalytic materials, membranes, and fabrication technologies suitable for the construction of amperometric biosensors
    • Newman J.D., White S.F., Tothill I.E., Turner A.P.F. Catalytic materials, membranes, and fabrication technologies suitable for the construction of amperometric biosensors. Anal. Chem. 67:1995;4594-4599.
    • (1995) Anal. Chem. , vol.67 , pp. 4594-4599
    • Newman, J.D.1    White, S.F.2    Tothill, I.E.3    Turner, A.P.F.4
  • 16
    • 0032998871 scopus 로고    scopus 로고
    • Screen-printed amperometric biosensors for the rapid measurement of L- and D-amino acids
    • Sarkar P., Tothill I.E., Setford S.J., Turner A.P.F. Screen-printed amperometric biosensors for the rapid measurement of L- and D-amino acids. Analyst. 124:1999;865-870.
    • (1999) Analyst , vol.124 , pp. 865-870
    • Sarkar, P.1    Tothill, I.E.2    Setford, S.J.3    Turner, A.P.F.4
  • 17
    • 0028141078 scopus 로고
    • Screen-printed glucose strip based on palladium-dispersed carbon ink
    • Wang J., Chen Q. Screen-printed glucose strip based on palladium-dispersed carbon ink. Analyst. 119:1994;1849-1851.
    • (1994) Analyst , vol.119 , pp. 1849-1851
    • Wang, J.1    Chen, Q.2
  • 18
    • 0028873945 scopus 로고
    • Screen-printed amperometric bisoensors for glucose and alcohols based on ruthenium-dispersed carbon inks
    • Wang J., Chen Q., Pedrero M., Pingarron J.M. Screen-printed amperometric bisoensors for glucose and alcohols based on ruthenium-dispersed carbon inks. Anal. Chim. Acta. 300:1995;111-116.
    • (1995) Anal. Chim. Acta , vol.300 , pp. 111-116
    • Wang, J.1    Chen, Q.2    Pedrero, M.3    Pingarron, J.M.4
  • 19
    • 4544314211 scopus 로고
    • Palladium-doped screen-printed electrodes for monitoring formaldehyde
    • Wang J., Pedrero M., Cai X. Palladium-doped screen-printed electrodes for monitoring formaldehyde. Analyst. 120:1995;1969-1972.
    • (1995) Analyst , vol.120 , pp. 1969-1972
    • Wang, J.1    Pedrero, M.2    Cai, X.3
  • 20
  • 21
    • 0024990065 scopus 로고
    • Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor application
    • Wring S.A., Hart J.P., Bracey L., Birch B. Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor application. Anal. Chim. Acta. 231:1990;203-212.
    • (1990) Anal. Chim. Acta , vol.231 , pp. 203-212
    • Wring, S.A.1    Hart, J.P.2    Bracey, L.3    Birch, B.4
  • 22
    • 37049069241 scopus 로고
    • Chemically modified, carbon-based electrodes and their application as electrochemical sensors for the analysis of biologically important compounds
    • Wring S.A., Hart J.P. Chemically modified, carbon-based electrodes and their application as electrochemical sensors for the analysis of biologically important compounds. Analyst. 117:1992;1215-1229.
    • (1992) Analyst , vol.117 , pp. 1215-1229
    • Wring, S.A.1    Hart, J.P.2
  • 23
    • 0034324542 scopus 로고    scopus 로고
    • Chemometric analysis of square wave voltammograms for classification and quantitation of untreated beverage samples
    • Schreyer S.K., Mikkelsen S.R. Chemometric analysis of square wave voltammograms for classification and quantitation of untreated beverage samples. Sens. Actuators B. 71:2000;147-153.
    • (2000) Sens. Actuators B , vol.71 , pp. 147-153
    • Schreyer, S.K.1    Mikkelsen, S.R.2
  • 26
    • 0034296070 scopus 로고    scopus 로고
    • Response time based output of metal oxide gas sensors applied to evaluation of meat freshness with neural signal analysis
    • Galdikas A., Mironas A., Senuliene D., Strazdiene A., Setkus A., Zelenin D. Response time based output of metal oxide gas sensors applied to evaluation of meat freshness with neural signal analysis. Sens. Actuators B. 69:2000;258-265.
    • (2000) Sens. Actuators B , vol.69 , pp. 258-265
    • Galdikas, A.1    Mironas, A.2    Senuliene, D.3    Strazdiene, A.4    Setkus, A.5    Zelenin, D.6
  • 27
    • 0034322333 scopus 로고    scopus 로고
    • Extracting information from noise spectra of chemical sensors: Single sensor electronic noses and tongues
    • Kish L.B., Vajtai R., Granqvist C.G. Extracting information from noise spectra of chemical sensors: single sensor electronic noses and tongues. Sens. Actuators B. 71:2000;55-59.
    • (2000) Sens. Actuators B , vol.71 , pp. 55-59
    • Kish, L.B.1    Vajtai, R.2    Granqvist, C.G.3
  • 28
    • 0001739577 scopus 로고    scopus 로고
    • Simultaneous mixture analysis using a dynamic microbial sensor combined with chemometrics
    • Slama M., Zaborosch C., Wienke D., Spener F. Simultaneous mixture analysis using a dynamic microbial sensor combined with chemometrics. Anal. Chem. 68:1996;3845-3850.
    • (1996) Anal. Chem. , vol.68 , pp. 3845-3850
    • Slama, M.1    Zaborosch, C.2    Wienke, D.3    Spener, F.4
  • 29
    • 0031250745 scopus 로고    scopus 로고
    • Chemometrical studies on mixture analysis with a single dynamic microbial sensor
    • Slama M., Zaborosch C., Wienke D., Spener F. Chemometrical studies on mixture analysis with a single dynamic microbial sensor. Sens. Actuators B. 44:1997;286-290.
    • (1997) Sens. Actuators B , vol.44 , pp. 286-290
    • Slama, M.1    Zaborosch, C.2    Wienke, D.3    Spener, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.