메뉴 건너뛰기




Volumn 22, Issue 6, 2003, Pages 562-568

Q-switched 2.94-μm Er:YAG laser trephination with convergent and divergent cut angles for penetrating keratoplasty

Author keywords

Convergent cut angles; Divergent cut angles; Er:YAG laser trephination; Penetrating keratoplasty; Thermal damage

Indexed keywords

ANIMAL TISSUE; ARTICLE; CORNEA SURGERY; CORNEA TRANSPLANTATION; IMAGE PROCESSING; KERATOMETRY; LASER SURGERY; NONHUMAN; PENETRATING KERATOPLASTY; PRIORITY JOURNAL; RECIPIENT; ROTATION; SKULL SURGERY; SWINE; THERMAL INJURY; YAG LASER;

EID: 0038088461     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003226-200308000-00015     Document Type: Article
Times cited : (5)

References (38)
  • 1
    • 0027143917 scopus 로고
    • 193 nm excimer laser trephination in perforating keratoplasty: Report of 70 patients
    • Naumann GOH, Seitz B, Lang GK, et al. 193 nm excimer laser trephination in perforating keratoplasty: report of 70 patients [in German]. Klin Monatsbl Augenheilkd. 1993;203:252-61.
    • (1993) Klin Monatsbl Augenheilkd , vol.203 , pp. 252-261
    • Naumann, G.O.H.1    Seitz, B.2    Lang, G.K.3
  • 2
    • 0024430176 scopus 로고
    • Configuration of corneal cuts performed with an excimer laser: An experimental study
    • Lang GK, Koch JW, Schroeder E, et al. Configuration of corneal cuts performed with an excimer laser: an experimental study [in German]. Fortschr Ophthalmol. 1989;86:437-42.
    • (1989) Fortschr Ophthalmol , vol.86 , pp. 437-442
    • Lang, G.K.1    Koch, J.W.2    Schroeder, E.3
  • 3
    • 0025367029 scopus 로고
    • A new elliptical excision for corneal transplantation using an excimer laser
    • Lang GK, Naumann GOH, Koch JW. A new elliptical excision for corneal transplantation using an excimer laser. Arch Ophthalmol. 1990;108:914-5.
    • (1990) Arch Ophthalmol , vol.108 , pp. 914-915
    • Lang, G.K.1    Naumann, G.O.H.2    Koch, J.W.3
  • 4
    • 0024356094 scopus 로고
    • Excimer laser keratoplasty, part 2: Elliptical keratoplasty
    • Lang GK, Schroeder E, Koch JW, et al. Excimer laser keratoplasty, part 2: elliptical keratoplasty. Ophthalmic Surg. 1989:20:342-6.
    • (1989) Ophthalmic Surg , vol.20 , pp. 342-346
    • Lang, G.K.1    Schroeder, E.2    Koch, J.W.3
  • 5
    • 0026529388 scopus 로고
    • The excimer laser as a tool in corneal surgery
    • Seiler T. The excimer laser as a tool in corneal surgery [in German]. Ophthalmologe. 1992;89:128-33.
    • (1992) Ophthalmologe , vol.89 , pp. 128-133
    • Seiler, T.1
  • 6
    • 0000893103 scopus 로고
    • The Bowman lecture. Part II: Corneal transplantation in anterior segment diseases
    • Naumann GOH. The Bowman lecture. Part II: corneal transplantation in anterior segment diseases. Eye. 1995;9:398-421.
    • (1995) Eye , vol.9 , pp. 398-421
    • Naumann, G.O.H.1
  • 7
    • 0030163119 scopus 로고    scopus 로고
    • Regularity of corneal topography after penetrating keratoplasty: Comparison between nonmechanical (excimer laser 193 nm) and mechanical trephination
    • Langenbucher A, Seitz B, Kus MM, et al. Regularity of corneal topography after penetrating keratoplasty: comparison between nonmechanical (excimer laser 193 nm) and mechanical trephination [in German]. Klin Monatsbl Augenheilkd. 1996;208:450-8.
    • (1996) Klin Monatsbl Augenheilkd , vol.208 , pp. 450-458
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3
  • 8
    • 0031964273 scopus 로고    scopus 로고
    • Regularity of laser keratectomy depth in nonmechanical trephination for penetrating keratoplasty
    • Seitz B, Langenbucher A, Fischer S, et al. Regularity of laser keratectomy depth in nonmechanical trephination for penetrating keratoplasty. Ophthalmic Surg Lasers. 1998;29:33-42.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 33-42
    • Seitz, B.1    Langenbucher, A.2    Fischer, S.3
  • 9
    • 0032005392 scopus 로고    scopus 로고
    • Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty
    • Küchle M, Nguyen NX, Seitz B, et al. Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty. Am J Ophthalmol. 1998;125:177-81.
    • (1998) Am J Ophthalmol , vol.125 , pp. 177-181
    • Küchle, M.1    Nguyen, N.X.2    Seitz, B.3
  • 10
    • 0031890854 scopus 로고    scopus 로고
    • Graft decentration in penetrating keratoplasty: Nonmechanical trephination with the excimer laser (193 nm) versus the motor trephine
    • Langenbucher A, Seitz B, Kus MM, et al. Graft decentration in penetrating keratoplasty: nonmechanical trephination with the excimer laser (193 nm) versus the motor trephine. Ophthalmic Surg Lasers. 1998;29:106-13.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 106-113
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3
  • 11
    • 0033504303 scopus 로고    scopus 로고
    • Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty
    • Seitz B, Langenbucher A, Kus MM, et al. Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty. Ophthalmology. 1999;106:1156-65.
    • (1999) Ophthalmology , vol.106 , pp. 1156-1165
    • Seitz, B.1    Langenbucher, A.2    Kus, M.M.3
  • 12
    • 0033511524 scopus 로고    scopus 로고
    • Nonmechanical excimer laser penetrating keratoplasty for perforated or predescemetal corneal ulcers
    • Küchle M, Seitz B, Langenbucher A, et al. Nonmechanical excimer laser penetrating keratoplasty for perforated or predescemetal corneal ulcers. Ophthalmology. 1999;106:2203-9.
    • (1999) Ophthalmology , vol.106 , pp. 2203-2209
    • Küchle, M.1    Seitz, B.2    Langenbucher, A.3
  • 13
    • 0033803066 scopus 로고    scopus 로고
    • Decentration of donor cornea in mechanical and excimer laser trephination for penetrating keratoplastik
    • Seitz B, Langenbucher A, Meiller R, et al. Decentration of donor cornea in mechanical and excimer laser trephination for penetrating keratoplastik [in German]. Klin Monatsbl Augenheilkd. 2000;217:144-51.
    • (2000) Klin Monatsbl Augenheilkd , vol.217 , pp. 144-151
    • Seitz, B.1    Langenbucher, A.2    Meiller, R.3
  • 14
    • 0031780341 scopus 로고    scopus 로고
    • Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty
    • Seitz B, Behrens A, Langenbucher A, et al. Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty. Cornea. 1998;17:410-6.
    • (1998) Cornea , vol.17 , pp. 410-416
    • Seitz, B.1    Behrens, A.2    Langenbucher, A.3
  • 15
    • 0345466323 scopus 로고    scopus 로고
    • Free-running erbium:YAG laser for nonmechanical trephination in penetrating keratoplasty: First results of experimental trephination of human donor corneas
    • Küchle M, Behrens A, Seitz B, et al. Free-running erbium:YAG laser for nonmechanical trephination in penetrating keratoplasty: first results of experimental trephination of human donor corneas. Graefes Arch Clin Exp Ophthalmol. 1999;237:875-7.
    • (1999) Graefes Arch Clin Exp Ophthalmol , vol.237 , pp. 875-877
    • Küchle, M.1    Behrens, A.2    Seitz, B.3
  • 16
    • 0031708016 scopus 로고    scopus 로고
    • Stromal thermal effects induced by nonmechanical (2.94 μm) Er:YAG laser corneal trephination
    • Behrens A, Küchle M, Seitz B, et al. Stromal thermal effects induced by nonmechanical (2.94 μm) Er:YAG laser corneal trephination. Arch Ophthalmol. 1998;116:1342-8.
    • (1998) Arch Ophthalmol , vol.116 , pp. 1342-1348
    • Behrens, A.1    Küchle, M.2    Seitz, B.3
  • 17
    • 0032738122 scopus 로고    scopus 로고
    • Design of a computer-generated hologram with a ring focus for nonmechanical corneal trephination with the Er:YAG laser in penetrating keratoplasty
    • Langenbucher A, Seitz B, Kus MM, et al. Design of a computer-generated hologram with a ring focus for nonmechanical corneal trephination with the Er:YAG laser in penetrating keratoplasty. Jpn J Ophthalmol. 1999;43:453-7.
    • (1999) Jpn J Ophthalmol , vol.43 , pp. 453-457
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3
  • 18
    • 0024336753 scopus 로고
    • Corneal ablation in rabbits using an infrared (2.9 μm) erbium:YAG laser
    • Peyman GA, Badaro RM, Khoobehi B. Corneal ablation in rabbits using an infrared (2.9 μm) erbium:YAG laser. Ophthalmology. 1989;96:1160-70.
    • (1989) Ophthalmology , vol.96 , pp. 1160-1170
    • Peyman, G.A.1    Badaro, R.M.2    Khoobehi, B.3
  • 19
    • 0025301391 scopus 로고
    • Application of erbium:YAG laser in ocular ablation
    • Tsubota K. Application of erbium:YAG laser in ocular ablation. Ophthalmologica. 1990;200:117-22.
    • (1990) Ophthalmologica , vol.200 , pp. 117-122
    • Tsubota, K.1
  • 20
    • 0026037396 scopus 로고
    • Photoablation in ocular tissue using an Er:YAG-laser
    • Bende T, Seiler T, Wollensak J. Photoablation in ocular tissue using an Er:YAG-laser [in German]. Fortschr Ophthalmol. 1991;88:12-6.
    • (1991) Fortschr Ophthalmol , vol.88 , pp. 12-16
    • Bende, T.1    Seiler, T.2    Wollensak, J.3
  • 21
    • 0025789081 scopus 로고
    • Wound healing of the cornea after surface keratectomy: Er:YAG-excimer laser
    • Kahle G, Daqun X, Seiler T, et al. Wound healing of the cornea after surface keratectomy: Er:YAG-excimer laser [in German]. Fortschr Ophthalmol. 1991;88:380-5.
    • (1991) Fortschr Ophthalmol , vol.88 , pp. 380-385
    • Kahle, G.1    Daqun, X.2    Seiler, T.3
  • 22
    • 0025760479 scopus 로고
    • Long-term effect of Er:YAG laser (2.9 microns) on the primate cornea
    • Peyman GA, Beyer C, Kuszak J, et al. Long-term effect of Er:YAG laser (2.9 microns) on the primate cornea. Int Ophthalmol. 1991;15:249-58.
    • (1991) Int Ophthalmol , vol.15 , pp. 249-258
    • Peyman, G.A.1    Beyer, C.2    Kuszak, J.3
  • 23
    • 0026575868 scopus 로고
    • Tangential corneal surface ablation with 193- and 308-nm excimer and 2936-nm erbium-YAG laser irradiation
    • Belgorod BM, Ediger MN, Weiblinger RP, et al. Tangential corneal surface ablation with 193- and 308-nm excimer and 2936-nm erbium-YAG laser irradiation. Arch Ophthahnol. 1992;110:533-6.
    • (1992) Arch Ophthahnol , vol.110 , pp. 533-536
    • Belgorod, B.M.1    Ediger, M.N.2    Weiblinger, R.P.3
  • 24
    • 0026677720 scopus 로고
    • Thermal gradients in the cornea during photoablation with the Er:YAG
    • Bende T, Jean B, Matallana M. et al. Thermal gradients in the cornea during photoablation with the Er:YAG. Lasers Light Ophthalmol. 1992;5:79-82.
    • (1992) Lasers Light Ophthalmol , vol.5 , pp. 79-82
    • Bende, T.1    Jean, B.2    Matallana, M.3
  • 25
    • 0027008489 scopus 로고
    • Combined gaschromatography/mass ophthalmoscopy analysis of photoablative products after excimer- or Erbium:YAG laser treatment of human corneas
    • Kahle G, Städter H, Seiler T, et al. Combined gaschromatography/mass ophthalmoscopy analysis of photoablative products after excimer- or erbium:YAG laser treatment of human corneas [in German], Ophthalmologe. 1992;89:505-9.
    • (1992) Ophthalmologe , vol.89 , pp. 505-509
    • Kahle, G.1    Städter, H.2    Seiler, T.3
  • 26
    • 0027352097 scopus 로고
    • Influence of the pulse duration on photoablation with the Er:YAG laser in ocular tissue (cornea and sclera)
    • Bende T, Jean B, Matallana M, et al. Influence of the pulse duration on photoablation with the Er:YAG laser in ocular tissue (cornea and sclera) [in German]. Klin Monatsbl Augenheilkd. 1993:202:52-5.
    • (1993) Klin Monatsbl Augenheilkd , vol.202 , pp. 52-55
    • Bende, T.1    Jean, B.2    Matallana, M.3
  • 27
    • 0027310898 scopus 로고
    • Basic studies on photoablation of the cornea with pulsed 2.790 nm Er:Cr:YSGG laser
    • Lubatschowski H, Kermani O, Asshauer T. Basic studies on photoablation of the cornea with pulsed 2.790 nm Er:Cr:YSGG laser [in German]. Ophthalmologe. 1993;90:183-90.
    • (1993) Ophthalmologe , vol.90 , pp. 183-190
    • Lubatschowski, H.1    Kermani, O.2    Asshauer, T.3
  • 28
    • 0028153415 scopus 로고
    • Wet corneal surface ablation with the Er.YAG laser: Results in optimizing ablation
    • Bende T, Jean B, Matallana M, et al. Wet corneal surface ablation with the Er.YAG laser: results in optimizing ablation [in German]. Ophthalmologe. 1994;91:651-4.
    • (1994) Ophthalmologe , vol.91 , pp. 651-654
    • Bende, T.1    Jean, B.2    Matallana, M.3
  • 29
    • 0028858018 scopus 로고
    • Correction of myopia with Er:YAG laser fundamental mode photorefractive keratectomy
    • Jean B, Kriegerowski M, Matallana M, et al. Correction of myopia with Er:YAG laser fundamental mode photorefractive keratectomy. J Refract Surg. 1995;11:392-6.
    • (1995) J Refract Surg , vol.11 , pp. 392-396
    • Jean, B.1    Kriegerowski, M.2    Matallana, M.3
  • 31
    • 0029820177 scopus 로고    scopus 로고
    • Study of photoablation of rabbit corneas by Er:YAG laser
    • Cubeddu R, Brancato R, Sozzi C, et al. Study of photoablation of rabbit corneas by Er:YAG laser. Lasers Surg Med. 1996;19:32-9.
    • (1996) Lasers Surg Med , vol.19 , pp. 32-39
    • Cubeddu, R.1    Brancato, R.2    Sozzi, C.3
  • 32
    • 0033969230 scopus 로고    scopus 로고
    • Limitations of erbium:YAG laser photorefractive keratectomy
    • Mrochen M, Semshichen V, Funk RH, et al. Limitations of erbium:YAG laser photorefractive keratectomy. J Refract Surg. 2000;16:51-9.
    • (2000) J Refract Surg , vol.16 , pp. 51-59
    • Mrochen, M.1    Semshichen, V.2    Funk, R.H.3
  • 33
    • 0032827239 scopus 로고    scopus 로고
    • "Orientation teeth" in nonmechanical laser corneal trephination: 2.94-μm Er:YAG laser vs. 193-nm ArF excimer laser
    • Behrens A, Seitz B, Küchle M, et al. "Orientation teeth" in nonmechanical laser corneal trephination: 2.94-μm Er:YAG laser vs. 193-nm ArF excimer laser. Br J Ophthalmol. 1999;83:1008-12.
    • (1999) Br J Ophthalmol , vol.83 , pp. 1008-1012
    • Behrens, A.1    Seitz, B.2    Küchle, M.3
  • 34
    • 0342313582 scopus 로고    scopus 로고
    • Thermal load of laser aperture masks in nonmechanical trephination for penetrating keratoplasty with the Er:YAG laser: Comparison between stainless steel and ceramic masks
    • Langenbucher A, Küchle M, Seitz B, et al. Thermal load of laser aperture masks in nonmechanical trephination for penetrating keratoplasty with the Er:YAG laser: comparison between stainless steel and ceramic masks. Graefes Arch Clin Exp Ophthalmol. 2000;238:339-45.
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 339-345
    • Langenbucher, A.1    Küchle, M.2    Seitz, B.3
  • 35
    • 0030788439 scopus 로고    scopus 로고
    • Photovaporization rate and profile of an erbium-chromium:YAG laser in the fundamental mode
    • Holschbach A, Wirbelauer C, Krämer T, et al. Photovaporization rate and profile of an erbium-chromium:YAG laser in the fundamental mode. J Cataract Refract Surg. 1997;23:726-30.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 726-730
    • Holschbach, A.1    Wirbelauer, C.2    Krämer, T.3
  • 37
    • 0022516398 scopus 로고
    • A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser
    • Marshall J, Trokel S, Rothery S, et al. A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser. Br J Ophthalmol. 1986;70:482-501.
    • (1986) Br J Ophthalmol , vol.70 , pp. 482-501
    • Marshall, J.1    Trokel, S.2    Rothery, S.3
  • 38
    • 0024651688 scopus 로고
    • Excimer laser keratoplasty, part I: Basic concepts
    • Lang GK, Schroeder E, Koch JW, et al. Excimer laser keratoplasty, part I: basic concepts. Ophthalmic Surg. 1989;20:262-7.
    • (1989) Ophthalmic Surg , vol.20 , pp. 262-267
    • Lang, G.K.1    Schroeder, E.2    Koch, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.