메뉴 건너뛰기




Volumn 208, Issue 6, 1996, Pages 450-458

Regularity of corneal topography after penetrating keratoplasty - Nonmechanical trephination with the Excinier Laser 193 nm vs mechanical trephination;Regularität der hornhauttopographie nach perforierender keratoplastik - Vergleich zwischen nichtmechanischer (Excimer-Laser-193 nm) und mechanischer trepanation

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; ASTIGMATISM; COMPARATIVE STUDY; CONGENITAL CORNEA DYSTROPHY; EYE REFRACTION; FEMALE; FOLLOW UP; HUMAN; INSTRUMENTATION; KERATOCONUS; LASER; MALE; MIDDLE AGED; PENETRATING KERATOPLASTY; PHYSIOLOGY; POSTOPERATIVE COMPLICATION; VISUAL ACUITY;

EID: 0030163119     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1035263     Document Type: Article
Times cited : (50)

References (31)
  • 1
    • 0026637133 scopus 로고
    • Visual outcome after penetrating keratoplasty with double continuous or combined interrupted and continuous sutures for wound closure
    • Assil KK, Zarnegar SR, Schanzlin DJ, Visual outcome after penetrating keratoplasty with double continuous or combined interrupted and continuous sutures for wound closure. Am J Ophthalmol 1992; 114:63-71
    • (1992) Am J Ophthalmol , vol.114 , pp. 63-71
    • Assil, K.K.1    Zarnegar, S.R.2    Schanzlin, D.J.3
  • 3
    • 0025322759 scopus 로고
    • Classification of normal corneal topography based on computer-assisted video-keratography
    • Bogan SJ, Waring GO, Osama I, Drews C, Curtis L. Classification of normal corneal topography based on computer-assisted video-keratography. Arch Ophthalmol 1990, 108:945-949
    • (1990) Arch Ophthalmol , vol.108 , pp. 945-949
    • Bogan, S.J.1    Waring, G.O.2    Osama, I.3    Drews, C.4    Curtis, L.5
  • 5
    • 0015115403 scopus 로고
    • Neue Schneidetechnik in der Mikrochirurgie
    • Draeger J Neue Schneidetechnik in der Mikrochirurgie. Klin Monatsbl Augenheilkd 1971; 159:293-303
    • (1971) Klin Monatsbl Augenheilkd , vol.159 , pp. 293-303
    • Draeger, J.1
  • 6
    • 0029010154 scopus 로고
    • Fourier-Analysis of photokeratographic data - A tool for separation of spherical, regular astigmatism and irregular astigmatic corneal power components
    • Hjortdal JO, Erdmann L, Bek T. Fourier-Analysis of photokeratographic data - a tool for separation of spherical, regular astigmatism and irregular astigmatic corneal power components. Ophthalmic and Physiological Optics 1995; 15(3):171-185
    • (1995) Ophthalmic and Physiological Optics , vol.15 , Issue.3 , pp. 171-185
    • Hjortdal, J.O.1    Erdmann, L.2    Bek, T.3
  • 8
    • 0017019026 scopus 로고
    • Nahttechnik bei perforierender Keratoplastik
    • Hoffmann F. Nahttechnik bei perforierender Keratoplastik. Klin Monatsbl Augenheilkd 1976; 169:584-590
    • (1976) Klin Monatsbl Augenheilkd , vol.169 , pp. 584-590
    • Hoffmann, F.1
  • 10
    • 0001407285 scopus 로고
    • The pathophysiology of corneal astigmatism after cataract extraction
    • Jaffe NS, Clayman HM. The pathophysiology of corneal astigmatism after cataract extraction. Trans Am Acad Ophthalmol 1975; 79:615-630
    • (1975) Trans Am Acad Ophthalmol , vol.79 , pp. 615-630
    • Jaffe, N.S.1    Clayman, H.M.2
  • 11
  • 13
    • 0022614933 scopus 로고
    • Clinicopathologic studies of keratoplasty eyes obtained post mortem
    • Lang GK, Green WR, Maumenee AE. Clinicopathologic studies of keratoplasty eyes obtained post mortem. Am J Ophthalmol 1986; 101:28-40
    • (1986) Am J Ophthalmol , vol.101 , pp. 28-40
    • Lang, G.K.1    Green, W.R.2    Maumenee, A.E.3
  • 14
    • 2642685957 scopus 로고
    • Graft decentration in penetrating keratoplasty - Excimer laser trephination versus motor trephination
    • Langenbucher A, Seitz B, Kus MM, Naumann GOH. Graft decentration in penetrating keratoplasty - excimer laser trephination versus motor trephination. Invest Ophthalmol Vis Sci 1994, 35(4):1879
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , Issue.4 , pp. 1879
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3    Naumann, G.O.H.4
  • 16
    • 0000950690 scopus 로고
    • Surgical procedures of the cornea
    • Blodi FC, Mackensen G, Neubauer H (eds.): Berlin: Springer
    • Naumann GOH, Sautter, Surgical procedures of the cornea. In: Blodi FC, Mackensen G, Neubauer H (eds.): Surgical Ophthalmology 1. Berlin: Springer, 1991
    • (1991) Surgical Ophthalmology 1
    • Naumann, G.O.H.1    Sautter2
  • 17
    • 0027143917 scopus 로고
    • Excimer-Laser 193nm-Trepanation bei der perforierenden Keratoplastik - Bericht über die ersten 70 Patienten
    • Naumann GOH, Seitz B, Lang GK, Langenbucher A, Kus MM. Excimer-Laser 193nm-Trepanation bei der perforierenden Keratoplastik - Bericht über die ersten 70 Patienten. Klin Monatsbl Augenheilkd 1993; 203:252-259
    • (1993) Klin Monatsbl Augenheilkd , vol.203 , pp. 252-259
    • Naumann, G.O.H.1    Seitz, B.2    Lang, G.K.3    Langenbucher, A.4    Kus, M.M.5
  • 18
    • 0029166860 scopus 로고
    • Corneal transplantation in anterior segment descases. The Bowman Lecture (Number 56) Part II
    • Naumann GOH. Corneal transplantation in anterior segment descases. The Bowman Lecture (Number 56) Part II: Eye 1995:395-424
    • (1995) Eye , pp. 395-424
    • Naumann, G.O.H.1
  • 19
    • 0005399949 scopus 로고
    • Excimer laser 193nm trephination with "orientation teeth" in penetrating keratoplasty
    • Naumann GOH, Seitz B. Excimer laser 193nm trephination with "orientation teeth" in penetrating keratoplasty. Ophthalmology 1992; 99(Suppl.)(9):122
    • (1992) Ophthalmology , vol.99 , Issue.9 SUPPL. , pp. 122
    • Naumann, G.O.H.1    Seitz, B.2
  • 20
    • 0027446446 scopus 로고
    • Changes in keratometric astigmatism after suture removal more than one year after penetrating keratoplasty
    • Mader TH, Yuan R, Lynn MJ, Stulting RD, Wilson LA, Waring GO. Changes in keratometric astigmatism after suture removal more than one year after penetrating keratoplasty. Ophthalmology 1993; 100:119-127
    • (1993) Ophthalmology , vol.100 , pp. 119-127
    • Mader, T.H.1    Yuan, R.2    Lynn, M.J.3    Stulting, R.D.4    Wilson, L.A.5    Waring, G.O.6
  • 22
    • 0027178854 scopus 로고
    • Über die mathematische Darstellung des post-operativen regulären Hornhautastigmatismus
    • Seiler T, Wollensak J. Über die mathematische Darstellung des post-operativen regulären Hornhautastigmatismus. Klin Monatsbl Augenheilkd 1993; 203:70-76
    • (1993) Klin Monatsbl Augenheilkd , vol.203 , pp. 70-76
    • Seiler, T.1    Wollensak, J.2
  • 24
    • 0010551673 scopus 로고
    • Consideration of donor and recipient corneal topography improves graft alignment in penetrating keratoplasty
    • Seitz B, Langenbucher A, Kus MM, Naumann GOH. Consideration of donor and recipient corneal topography improves graft alignment in penetrating keratoplasty. Invest Ophthalmol Vis Sci 1994; 35(Suppl.):1879
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , Issue.SUPPL. , pp. 1879
    • Seitz, B.1    Langenbucher, A.2    Kus, M.M.3    Naumann, G.O.H.4
  • 25
    • 5244292457 scopus 로고
    • Aufeinan-derabstimmung von Spender- und Empfänger-Topographie bei der perforierenden Keratoplastik - Erster klinischer Einsatz
    • Seitz B, Langenbucher A, Kus MM, Naumann GOH. Aufeinan-derabstimmung von Spender- und Empfänger-Topographie bei der perforierenden Keratoplastik - erster klinischer Einsatz. Ophthalmologe 1994; 91(Suppl. 1):49 Harmonizing of donor and recipient corneal topography in penetrating keratoplasty -first clinical application. German J Ophthalmol 1994; 3:310
    • (1994) Ophthalmologe , vol.91 , Issue.1 SUPPL. , pp. 49
    • Seitz, B.1    Langenbucher, A.2    Kus, M.M.3    Naumann, G.O.H.4
  • 26
    • 0344191535 scopus 로고
    • Harmonizing of donor and recipient corneal topography in penetrating keratoplasty -first clinical application
    • Seitz B, Langenbucher A, Kus MM, Naumann GOH. Aufeinan-derabstimmung von Spender- und Empfänger-Topographie bei der perforierenden Keratoplastik - erster klinischer Einsatz. Ophthalmologe 1994; 91(Suppl. 1):49 Harmonizing of donor and recipient corneal topography in penetrating keratoplasty -first clinical application. German J Ophthalmol 1994; 3:310
    • (1994) German J Ophthalmol , vol.3 , pp. 310
  • 27
    • 0000477051 scopus 로고
    • Quantitative and qualitative topography classification of clear penetrating keratoplasties
    • Tripoli NK, Ibrahim OS, Coggins JM et al. Quantitative and qualitative topography classification of clear penetrating keratoplasties Invest Ophthalmol Vis Sci 1990; 30(Suppl.):480
    • (1990) Invest Ophthalmol Vis Sci , vol.30 , Issue.SUPPL. , pp. 480
    • Tripoli, N.K.1    Ibrahim, O.S.2    Coggins, J.M.3
  • 28
    • 0018776295 scopus 로고
    • Astigmatic considerations in corneal graft
    • Troutman RC. Astigmatic considerations in corneal graft. Ophthalmic Surg 1979, 10:21-26
    • (1979) Ophthalmic Surg , vol.10 , pp. 21-26
    • Troutman, R.C.1
  • 29
    • 0023153567 scopus 로고
    • Centering corneal surgery procedures
    • Uozato H, Guyton DL. Centering corneal surgery procedures. Am J Ophthalmol 1987; 103:264-275
    • (1987) Am J Ophthalmol , vol.103 , pp. 264-275
    • Uozato, H.1    Guyton, D.L.2
  • 30
    • 0023882016 scopus 로고
    • The effect of pupil centration and diameter on ocular performance
    • Walsh G. Charman WN. The effect of pupil centration and diameter on ocular performance. Vis Res 1988; 28(5):659-665
    • (1988) Vis Res , vol.28 , Issue.5 , pp. 659-665
    • Walsh, G.1    Charman, W.N.2
  • 31
    • 0026065647 scopus 로고
    • Quantitative descriptors of corneal topography
    • Wilson SE, Klyce SD. Quantitative descriptors of corneal topography. Arch Ophthalmol 1991; 109:349-353
    • (1991) Arch Ophthalmol , vol.109 , pp. 349-353
    • Wilson, S.E.1    Klyce, S.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.