메뉴 건너뛰기




Volumn 125, Issue 1-2, 2003, Pages 1-5

Urea recirculation and dialysis efficiency of dual-lumen central venous catheters: Should the venous lumen of the catheter be used as arterial lumen, and vice versa?;Recirkulacija ureje I učinkovitost dijalize pri uporabi dvoluminalnih dijaliznih katetera različite lokalizacije: Smije li se venski krak katetera rabiti kao arterijski I obrnuto?

Author keywords

Catheterization, central venous instrumentation; Kidney failure therapy; Renal dialysis methods; Urea blood

Indexed keywords

UREA;

EID: 0038007922     PISSN: 00243477     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 0023378453 scopus 로고
    • Percent reduction in blood urea concentration during hemodialysis (PRU). A simple and accurate method to estimate Kt/V urea
    • Jindal KK, Manule A, Goldestein MB. Percent reduction in blood urea concentration during hemodialysis (PRU). A simple and accurate method to estimate Kt/V urea. ASAIO Trans 1987;33:286-8.
    • (1987) ASAIO Trans , vol.33 , pp. 286-288
    • Jindal, K.K.1    Manule, A.2    Goldestein, M.B.3
  • 6
    • 0035522634 scopus 로고    scopus 로고
    • Acute dialysis catheters
    • Oliver MJ. Acute dialysis catheters. Semin Dial 2001;14:432-5.
    • (2001) Semin Dial , vol.14 , pp. 432-435
    • Oliver, M.J.1
  • 7
    • 0035525488 scopus 로고    scopus 로고
    • The evaluation and function of central venous catheters for dialysis
    • Ash SR. The evaluation and function of central venous catheters for dialysis. Semin Dial 2001;14:416-24.
    • (2001) Semin Dial , vol.14 , pp. 416-424
    • Ash, S.R.1
  • 8
    • 0027304665 scopus 로고
    • Efficacy of dual lumen jugular venous catheter hemodialysis when venous lumen is used as arterial lumen
    • Sombolos K, Natse T, Zoumbaridis N, Mavromatidis K, Karagianni A, Fitili C. Efficacy of dual lumen jugular venous catheter hemodialysis when venous lumen is used as arterial lumen. Nephron 1993;65:147-9.
    • (1993) Nephron , vol.65 , pp. 147-149
    • Sombolos, K.1    Natse, T.2    Zoumbaridis, N.3    Mavromatidis, K.4    Karagianni, A.5    Fitili, C.6
  • 9
    • 0025240760 scopus 로고
    • The use of dual lumen jugular venous catheters as definitive long term access for haemodialysis
    • Blake PG, Huraib S, Wu G, Uldall PR. The use of dual lumen jugular venous catheters as definitive long term access for haemodialysis. Int J Artif Organs 1990;13:26-31.
    • (1990) Int J Artif Organs , vol.13 , pp. 26-31
    • Blake, P.G.1    Huraib, S.2    Wu, G.3    Uldall, P.R.4
  • 12
    • 0006490267 scopus 로고    scopus 로고
    • NKF-DOQI: Clinical practice guidelines for vascular access. Recirculation methodology, limits, evaluation, and follow-up
    • NKF-DOQI: Clinical practice guidelines for vascular access. Recirculation methodology, limits, evaluation, and follow-up. AJKD 1997;30:165-6.
    • (1997) AJKD , vol.30 , pp. 165-166
  • 13
    • 0035523345 scopus 로고    scopus 로고
    • Catheter access for hemodialysis: An overview
    • Butterly DW, Schwab SJ. Catheter access for hemodialysis: an overview. Semin Dial 2001;14:411-5.
    • (2001) Semin Dial , vol.14 , pp. 411-415
    • Butterly, D.W.1    Schwab, S.J.2
  • 15
    • 0035523894 scopus 로고    scopus 로고
    • Catheter performance
    • Depner TA. Catheter performance. Semin Dial 2001;14:425-31.
    • (2001) Semin Dial , vol.14 , pp. 425-431
    • Depner, T.A.1
  • 16
    • 0033647453 scopus 로고    scopus 로고
    • Access recirculation in temporary hemodialysis catheters as measured by saline dilution technique
    • Little MA, Conlon PJ, Walshe JJ. Access recirculation in temporary hemodialysis catheters as measured by saline dilution technique. Am J Kidney Dis 2000;36:1135-9.
    • (2000) Am J Kidney Dis , vol.36 , pp. 1135-1139
    • Little, M.A.1    Conlon, P.J.2    Walshe, J.J.3
  • 17
    • 0023280804 scopus 로고
    • Superior vena cava and hepatic vein Doppler echocardiography in healthy adults
    • Appleton CP, Hatle LK, Popp RL. Superior vena cava and hepatic vein Doppler echocardiography in healthy adults. J Am Coll Cardiol 1987;10: 1032-9.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 1032-1039
    • Appleton, C.P.1    Hatle, L.K.2    Popp, R.L.3
  • 18
    • 0030944146 scopus 로고    scopus 로고
    • Recirculation, urea disequilibrium, and dialysis access
    • Sherman RA, Kapoian T. Recirculation, urea disequilibrium, and dialysis access. Am J Kideny Dis 1997;29:479-89.
    • (1997) Am J Kideny Dis , vol.29 , pp. 479-489
    • Sherman, R.A.1    Kapoian, T.2
  • 20
    • 0031796623 scopus 로고    scopus 로고
    • All currently used measurements of recirculation in blood access by chemical methodes are flawed due to intradialytic disequilibrium or recirculation at low flow
    • Twardowski ZJ, Van Stone JC, Haynie JD. All currently used measurements of recirculation in blood access by chemical methodes are flawed due to intradialytic disequilibrium or recirculation at low flow. Am J Kidney Dis 1998;32:1046-58.
    • (1998) Am J Kidney Dis , vol.32 , pp. 1046-1058
    • Twardowski, Z.J.1    Van Stone, J.C.2    Haynie, J.D.3
  • 21
    • 0029875293 scopus 로고    scopus 로고
    • Blood recirculation in temporary central catheters for acute hemodialysis
    • Leblanc M, Fedak S, Mokris G, Paganini EP. Blood recirculation in temporary central catheters for acute hemodialysis. Clin Nephrol 1996;45: 315-9.
    • (1996) Clin Nephrol , vol.45 , pp. 315-319
    • Leblanc, M.1    Fedak, S.2    Mokris, G.3    Paganini, E.P.4
  • 22
    • 0006456524 scopus 로고    scopus 로고
    • NKF-DOQI: Clinical practice guideline for hemodialysis adequacy
    • NKF-DOQI: Clinical practice guideline for hemodialysis adequacy. Am J Kideny Dis 1997;30:15-66.
    • (1997) Am J Kideny Dis , vol.30 , pp. 15-66


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.