메뉴 건너뛰기




Volumn 14, Issue 6, 2001, Pages 432-435

Acute dialysis catheters

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE KIDNEY FAILURE; BACTERIAL INFECTION; CENTRAL VENOUS CATHETERIZATION; EQUIPMENT; HUMAN; INSTRUMENTATION; METHODOLOGY; RENAL REPLACEMENT THERAPY; REVIEW; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY;

EID: 0035522634     PISSN: 08940959     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-139x.2001.00107.x     Document Type: Article
Times cited : (74)

References (11)
  • 3
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
    • Randolph AG, Cook DJ, Gonzales CA, Pribble CG: Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 24:2051-2058, 1996
    • (1996) Crit Care Med , vol.24 , pp. 2051-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3    Pribble, C.G.4
  • 4
    • 0033995696 scopus 로고    scopus 로고
    • Importance of US findings in access planning during jugular vein hemodialysis catheter placements
    • Forauer AR, Glockner JF: Importance of US findings in access planning during jugular vein hemodialysis catheter placements. J Vasc Interv Radiol 11:233-238, 2000
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 233-238
    • Forauer, A.R.1    Glockner, J.F.2
  • 5
    • 0031962604 scopus 로고    scopus 로고
    • Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: An ultrasonographic survey in uraemic patients
    • Lin BS, Kong CW, Trang DC, Huang TP, Tamg GJ: Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: an ultrasonographic survey in uraemic patients. Nephrol Dial Transplant 13:134-138, 1998
    • (1998) Nephrol Dial Transplant , vol.13 , pp. 134-138
    • Lin, B.S.1    Kong, C.W.2    Trang, D.C.3    Huang, T.P.4    Tamg, G.J.5
  • 6
    • 0031945539 scopus 로고    scopus 로고
    • Brachial plexus compression due to subclavian pseudoaneurysm from cannulation of jugular vein hemodialysis catheter
    • Tarng DC, Huang TP, Lin KP: Brachial plexus compression due to subclavian pseudoaneurysm from cannulation of jugular vein hemodialysis catheter. Am J Kidney Dis 31:694-697, 1998
    • (1998) Am J Kidney Dis , vol.31 , pp. 694-697
    • Tarng, D.C.1    Huang, T.P.2    Lin, K.P.3
  • 10
    • 0026635451 scopus 로고
    • Prospective evaluation of a double-lumen subclavian dialysis catheter for acute vascular access
    • Silberman H, Berne TV, Escandon R: Prospective evaluation of a double-lumen subclavian dialysis catheter for acute vascular access. Am Surg 58:443-445, 1992
    • (1992) Am Surg , vol.58 , pp. 443-445
    • Silberman, H.1    Berne, T.V.2    Escandon, R.3
  • 11
    • 0031665038 scopus 로고    scopus 로고
    • Tricuspid regurgitation following central line insertion in a patient undergoing haemodialysis
    • Walsh JT, Glennon P, Schofield PM: Tricuspid regurgitation following central line insertion in a patient undergoing haemodialysis. Postgrad Med J 74:631-632, 1998
    • (1998) Postgrad Med J , vol.74 , pp. 631-632
    • Walsh, J.T.1    Glennon, P.2    Schofield, P.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.