메뉴 건너뛰기




Volumn 88, Issue 7, 2003, Pages 3069-3074

Phantoms in the assay tube: Heterophile antibody interferences in serum thyroglobulin assays

Author keywords

[No Author keywords available]

Indexed keywords

HETEROPHILE ANTIBODY; RADIOACTIVE IODINE; THYROGLOBULIN;

EID: 0037961087     PISSN: 0021972X     EISSN: None     Source Type: Journal    
DOI: 10.1210/jc.2003-030122     Document Type: Article
Times cited : (166)

References (29)
  • 1
    • 0032983264 scopus 로고    scopus 로고
    • Recombinant human thyrotropin symposium: Detection of residual and recurrent differentiated thyroid carcinoma by serum thyroglobulin measurement
    • Spencer CA, LoPresti JS, Fatemi S, Nicoloff JT 1999 Recombinant human thyrotropin symposium: detection of residual and recurrent differentiated thyroid carcinoma by serum thyroglobulin measurement. Thyroid 9:435-441
    • (1999) Thyroid , vol.9 , pp. 435-441
    • Spencer, C.A.1    LoPresti, J.S.2    Fatemi, S.3    Nicoloff, J.T.4
  • 2
    • 0034952673 scopus 로고    scopus 로고
    • Serum thyroglobulin measurement. Utility in clinical practice
    • Torréns JI, Burch HB 2001 Serum thyroglobulin measurement. Utility in clinical practice. Endocrinol Metab Clin North Am 30:429-467
    • (2001) Endocrinol Metab Clin North Am , vol.30 , pp. 429-467
    • Torréns, J.I.1    Burch, H.B.2
  • 4
    • 0030271219 scopus 로고    scopus 로고
    • Comparison of three immunoassay kits for serum thyroglobulin in patients with thyroid cancer
    • Dai J, Dent W, Atkinson JW, Cox JG, Dembinski TC 1996 Comparison of three immunoassay kits for serum thyroglobulin in patients with thyroid cancer. Clin Biochem 29:461-465
    • (1996) Clin Biochem , vol.29 , pp. 461-465
    • Dai, J.1    Dent, W.2    Atkinson, J.W.3    Cox, J.G.4    Dembinski, T.C.5
  • 6
    • 4243991012 scopus 로고    scopus 로고
    • Clinical performance of a chemiluminescent thyroglobulin assay on the Beckman Coulter's Access Immunoassay System
    • Mizrahi I, Bray K, Kapsner K, Nunnelly P, Parson R, Smith T, Preissner C, O'Kane D 2001 Clinical performance of a chemiluminescent thyroglobulin assay on the Beckman Coulter's Access Immunoassay System. Clin Chem 47(Suppl):A134
    • (2001) Clin Chem , vol.47 , Issue.SUPPL.
    • Mizrahi, I.1    Bray, K.2    Kapsner, K.3    Nunnelly, P.4    Parson, R.5    Smith, T.6    Preissner, C.7    O'Kane, D.8
  • 7
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka LJ 1999 Human anti-animal antibody interferences in immunological assays. Clin Chem 45:942-956
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 8
    • 0036844469 scopus 로고    scopus 로고
    • Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays
    • Levinson SS, Miller JJ 2002 Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays. Clin Chim Acta 325:1-15
    • (2002) Clin Chim Acta , vol.325 , pp. 1-15
    • Levinson, S.S.1    Miller, J.J.2
  • 9
    • 0029006508 scopus 로고
    • Iodine-131 therapy for thyroid cancer patients with elevated thyroglobulin and negative diagnostic scan
    • Pineda JD, Lee T, Ain K, Reynolds JC, Robbins J 1995 Iodine-131 therapy for thyroid cancer patients with elevated thyroglobulin and negative diagnostic scan. J Clin Endocrinol Metab 80:1488-1492
    • (1995) J Clin Endocrinol Metab , vol.80 , pp. 1488-1492
    • Pineda, J.D.1    Lee, T.2    Ain, K.3    Reynolds, J.C.4    Robbins, J.5
  • 10
    • 0029034183 scopus 로고
    • Treating high thyroglobulin with radioiodine: A magic bullet or a shot in the dark?
    • Mazzaferri EL 1995 Treating high thyroglobulin with radioiodine: a magic bullet or a shot in the dark? J Clin Endocrinol Metab 80:1485-1487
    • (1995) J Clin Endocrinol Metab , vol.80 , pp. 1485-1487
    • Mazzaferri, E.L.1
  • 12
    • 0036284398 scopus 로고    scopus 로고
    • Lack of impact of radioiodine therapy in tg-positive, diagnostic whole-body scan-negative patients with follicular cell-derived thyroid cancer
    • Fatourechi V, Hay ID, Javedan H, Wiseman GA, Mullan BP, Gorman CA 2002 Lack of impact of radioiodine therapy in tg-positive, diagnostic whole-body scan-negative patients with follicular cell-derived thyroid cancer. J Clin Endocrinol Metab 87:1521-1526
    • (2002) J Clin Endocrinol Metab , vol.87 , pp. 1521-1526
    • Fatourechi, V.1    Hay, I.D.2    Javedan, H.3    Wiseman, G.A.4    Mullan, B.P.5    Gorman, C.A.6
  • 14
    • 0030765913 scopus 로고    scopus 로고
    • Heterophilic antibodies remain a problem for the immunoassay laboratory
    • Ward G, McKinnon L, Badrick T, Hickman PE 1997 Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Path 108:417-421
    • (1997) Am J Clin Path , vol.108 , pp. 417-421
    • Ward, G.1    McKinnon, L.2    Badrick, T.3    Hickman, P.E.4
  • 17
    • 0030892115 scopus 로고    scopus 로고
    • Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population
    • Sosolik RC, Hitchcock CL, Becker WJ 1997 Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population. Am J Clin Pathol 107:506-510
    • (1997) Am J Clin Pathol , vol.107 , pp. 506-510
    • Sosolik, R.C.1    Hitchcock, C.L.2    Becker, W.J.3
  • 18
    • 0031911110 scopus 로고    scopus 로고
    • Antibody interference in thyroid assays: A potential for clinical misinformation
    • Despres N, Grant AM 1998 Antibody interference in thyroid assays: a potential for clinical misinformation. Clin Chem 44:440-454
    • (1998) Clin Chem , vol.44 , pp. 440-454
    • Despres, N.1    Grant, A.M.2
  • 21
    • 0035165378 scopus 로고    scopus 로고
    • Serum heterophile antibodies interfere with prostate specific antigen test and result in over treatment in a patient with prostate cancer
    • Morgan BR, Tarter TH 2001 Serum heterophile antibodies interfere with prostate specific antigen test and result in over treatment in a patient with prostate cancer. J Urol 166:2311-2312
    • (2001) J Urol , vol.166 , pp. 2311-2312
    • Morgan, B.R.1    Tarter, T.H.2
  • 22
    • 0036755571 scopus 로고    scopus 로고
    • False elevation of serum CA-125 level caused by human anti-mouse antibodies
    • Bertholf RL, Johannsen L, Guy B 2002 False elevation of serum CA-125 level caused by human anti-mouse antibodies. Ann Clin Lab Sci 32:414-418
    • (2002) Ann Clin Lab Sci , vol.32 , pp. 414-418
    • Bertholf, R.L.1    Johannsen, L.2    Guy, B.3
  • 25
    • 0033869592 scopus 로고    scopus 로고
    • An IgM λ antibody to Escherichia coli produces false-positive results in multiple immunometric assays
    • Covinsky M, Laterza O, Peiffer JD, Farkas-Szailasi T, Scott MG 2000 An IgM λ antibody to Escherichia coli produces false-positive results in multiple immunometric assays. Clin Chem 46:1157-1161
    • (2000) Clin Chem , vol.46 , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Peiffer, J.D.3    Farkas-Szailasi, T.4    Scott, M.G.5
  • 26
    • 0034716473 scopus 로고    scopus 로고
    • False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations
    • Rotmensch S, Cole LA 2000 False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations. Lancet 355:712-715
    • (2000) Lancet , vol.355 , pp. 712-715
    • Rotmensch, S.1    Cole, L.A.2
  • 27
    • 0036855092 scopus 로고    scopus 로고
    • Committee opinion: Number 278, November 2002. Avoiding inappropriate clinical decisions based on false-positive human chorionic gonadotropin test results
    • ACOG
    • Committee on Gynecologic Practice American College of Obstetricians and Gynecologists 2002 ACOG. Committee opinion: number 278, November 2002. Avoiding inappropriate clinical decisions based on false-positive human chorionic gonadotropin test results. Obstet Gynecol 100:1057-1059
    • (2002) Obstet Gynecol , vol.100 , pp. 1057-1059
  • 28
    • 0034026889 scopus 로고    scopus 로고
    • Transient nature of interference effects from heterophile antibodies: Examples of interference with cardiac marker measurements
    • Kazmierczak SC, Catrou PG, Briley KP 2000 Transient nature of interference effects from heterophile antibodies: examples of interference with cardiac marker measurements. Clin Chem Lab Med 38:33-39
    • (2000) Clin Chem Lab Med , vol.38 , pp. 33-39
    • Kazmierczak, S.C.1    Catrou, P.G.2    Briley, K.P.3
  • 29
    • 0027289121 scopus 로고
    • Survey of methods for measuring human antimouse antibodies
    • HAMA survey group 1993 Survey of methods for measuring human antimouse antibodies. Clin Chim Acta 215:153-163
    • (1993) Clin Chim Acta , vol.215 , pp. 153-163


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.