0035095859
-
Mercury sphygmomanometers should not be abandoned: An advisory statement from the Council for High Blood Pressure Research, American Heart Association
-
Jones DW, Frohlich ED, Grim CM, Grim CE, Taubert KA, for the Professional Education Committee, Council for High Blood Pressure Research. Mercury sphygmomanometers should not be abandoned: an advisory statement from the Council for High Blood Pressure Research, American Heart Association. Hypertension 2001; 31:185-186.
-
(2001)
Hypertension
, vol.31
, pp. 185-186
-
-
Jones, D.W.1
Frohlich, E.D.2
Grim, C.M.3
Grim, C.E.4
Taubert, K.A.5
-
2
-
-
0035203057
-
The case for a hybrid sphygmomanometer
-
Pickering T. The case for a hybrid sphygmomanometer. Blood Press Monit 2001; 6:177-179.
-
(2001)
Blood Press Monit
, vol.6
, pp. 177-179
-
-
Pickering, T.1
-
3
-
-
0033237294
-
An electronic manometer for blood pressure measurement
-
Burke MJ. An electronic manometer for blood pressure measurement. J Med Eng Technol 1999; 23:197-202.
-
(1999)
J Med Eng Technol
, vol.23
, pp. 197-202
-
-
Burke, M.J.1
-
4
-
-
0027218269
-
The British Hypertension Society protocol for the evaluation of blood pressure measuring devices
-
O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, Altman DG et al. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11 (suppl 2):S43-S62.
-
(1993)
J Hypertens
, vol.11
, Issue.SUPPL. 2
-
-
O'Brien, E.1
Petrie, J.2
Littler, W.3
De Swiet, M.4
Padfield, P.L.5
Altman, D.G.6
-
6
-
-
0035992025
-
Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
-
O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J et al., on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
-
(2002)
Blood Press Monit
, vol.7
, pp. 3-17
-
-
O'Brien, E.1
Pickering, T.2
Asmar, R.3
Myers, M.4
Parati, G.5
Staessen, J.6
-
7
-
-
0025800276
-
Aneroid sphygmomanometers: An assessment of accuracy at a university hospital and clinics
-
Bailey RH, Knaus VL, Bauer JH. Aneroid sphygmomanometers: an assessment of accuracy at a university hospital and clinics. Arch Intern Med 1991; 151:1409-1412.
-
(1991)
Arch Intern Med
, vol.151
, pp. 1409-1412
-
-
Bailey, R.H.1
Knaus, V.L.2
Bauer, J.H.3
-
8
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
9
-
-
0035799041
-
Blood pressure measuring devices: Recommendations of the European Society of Hypertension
-
O'Brien E, Waeber B, Parati G, Staessen J, Myers MG, on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001; 322:531-536.
-
(2001)
BMJ
, vol.322
, pp. 531-536
-
-
O'Brien, E.1
Waeber, B.2
Parati, G.3
Staessen, J.4
Myers, M.G.5
-
10
-
-
0025645801
-
Clinical assessment of blood pressure
-
McKay DW, Campbell NR, Parab LS, Chockalingam A, Fodor JG. Clinical assessment of blood pressure. J Hum Hypertens 1990; 4:639-645.
-
(1990)
J Hum Hypertens
, vol.4
, pp. 639-645
-
-
McKay, D.W.1
Campbell, N.R.2
Parab, L.S.3
Chockalingam, A.4
Fodor, J.G.5
-
11
-
-
0031957650
-
How accurate are sphygmomanometers?
-
Mion D, Pierin AM. How accurate are sphygmomanometers? J Hum Hypertens 1998; 12:245-248.
-
(1998)
J Hum Hypertens
, vol.12
, pp. 245-248
-
-
Mion, D.1
Pierin, A.M.2
-
12
-
-
0034956706
-
Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experience
-
Yarows SA, Qian K. Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experience. Blood Press Monit 2001; 6:101-106.
-
(2001)
Blood Press Monit
, vol.6
, pp. 101-106
-
-
Yarows, S.A.1
Qian, K.2
-
13
-
-
0023112579
-
Accuracy of prehospital sphygmomanometers
-
Jones JS, Ramsey W, Hetrick T. Accuracy of prehospital sphygmomanometers. J Emerg Med 1987; 5:23-27.
-
(1987)
J Emerg Med
, vol.5
, pp. 23-27
-
-
Jones, J.S.1
Ramsey, W.2
Hetrick, T.3
-
14
-
-
0036104884
-
Practice audits: Reliability of sphygmomanometers and blood pressure recording bias
-
Ali S, Rouse A. Practice audits: reliability of sphygmomanometers and blood pressure recording bias. J Hum Hypertens 2002; 16:359-361.
-
(2002)
J Hum Hypertens
, vol.16
, pp. 359-361
-
-
Ali, S.1
Rouse, A.2
-
15
-
-
0020069477
-
Sphygmomanometers in hospital and family practice: Problems and recommendations
-
Burke MJ, Towers HM, O'Malley K, Fitzgerald DJ, O'Brien ET. Sphygmomanometers in hospital and family practice: problems and recommendations. BMJ 1982; 285:469-471.
-
(1982)
BMJ
, vol.285
, pp. 469-471
-
-
Burke, M.J.1
Towers, H.M.2
O'Malley, K.3
Fitzgerald, D.J.4
O'Brien, E.T.5
-
16
-
-
0029888007
-
An audit of the use of sphygmomanometers
-
Hussain A, Cox JG. An audit of the use of sphygmomanometers. Br J Clin Pract 1996; 50:136-137.
-
(1996)
Br J Clin Pract
, vol.50
, pp. 136-137
-
-
Hussain, A.1
Cox, J.G.2
-
17
-
-
0035848338
-
Are aneroid sphygmomanometers accurate in hospital and clinic settings?
-
Canzanello VJ, Jensen PL, Schwartz GL. Are aneroid sphygmomanometers accurate in hospital and clinic settings? Arch Intern Med 2001; 161:729-731.
-
(2001)
Arch Intern Med
, vol.161
, pp. 729-731
-
-
Canzanello, V.J.1
Jensen, P.L.2
Schwartz, G.L.3
-
18
-
-
0029557297
-
Patients achieve accurate home blood pressure measurement following instruction
-
Armstrong R, Barrack D, Gordon R. Patients achieve accurate home blood pressure measurement following instruction. Aust J Adv Nurs 1995; 12:15-21.
-
(1995)
Aust J Adv Nurs
, vol.12
, pp. 15-21
-
-
Armstrong, R.1
Barrack, D.2
Gordon, R.3
|