메뉴 건너뛰기




Volumn 32, Issue 6, 2003, Pages 477-483

Knee arthroplasty. Mobile- and fixed-bearing design;Knieendoprothetik: Mobiles vs. fixes Gleitlager

Author keywords

Fixed and mobile bearing design; Total knee arthroplasty

Indexed keywords

ARTICLE; BIOMEDICAL ENGINEERING; BIOMEDICAL TECHNOLOGY ASSESSMENT; HUMAN; KINEMATICS; KNEE ENDOPROSTHESIS; TOTAL KNEE REPLACEMENT;

EID: 0037897440     PISSN: 00854530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00132-003-0476-4     Document Type: Article
Times cited : (4)

References (30)
  • 1
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material on stresses in ultra-high molecular components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM (1986) The effect of conformity, thickness and material on stresses in ultra-high molecular components for total joint replacement. J Bone Joint Surg Am 68:1041-1051
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 3
    • 0025210147 scopus 로고
    • Dislocaton/subluxation of meniscal bearing elements after New Yersey low-contact Stress total knee arthroplasty
    • Bert JM (1990) Dislocaton/subluxation of meniscal bearing elements after New Yersey low-contact Stress total knee arthroplasty. Clin Orthop 254: 211-215
    • (1990) Clin Orthop , vol.254 , pp. 211-215
    • Bert, J.M.1
  • 4
    • 0031544587 scopus 로고    scopus 로고
    • Wear in retrieved condylar knee arthroplasties: A comparision of wear in differnet designs of 280 retrieved condylar knee protheses
    • Blunn G, Joshi AB, Minns RJ (1997) Wear in retrieved condylar knee arthroplasties: A comparision of wear in differnet designs of 280 retrieved condylar knee protheses. J Arthroplasty 12:281-290
    • (1997) J Arthroplasty , vol.12 , pp. 281-290
    • Blunn, G.1    Joshi, A.B.2    Minns, R.J.3
  • 5
    • 0022892456 scopus 로고
    • The New Yersey Low-Contact-Stress Knee Replacement System: Biomechanical raitionale and review of the first 123 cemented cases
    • Buechel FF, Pappas MJ (1986) The New Yersey Low-Contact-Stress Knee Replacement System: Biomechanical raitionale and review of the first 123 cemented cases. Arch Orthop Trauma Surg 105:197-204
    • (1986) Arch Orthop Trauma Surg , vol.105 , pp. 197-204
    • Buechel, F.F.1    Pappas, M.J.2
  • 6
    • 0034956403 scopus 로고    scopus 로고
    • Twenty-year evaluation of meniscal bearing and rotating platform knee replacements
    • Buechel FF, Buechel FFjr, Pappas MJ, D'Alessio J (2001) Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop 388:41-50
    • (2001) Clin Orthop , vol.388 , pp. 41-50
    • Buechel, F.F.1    Buechel F.F., Jr.2    Pappas, M.J.3    D'Alessio, J.4
  • 8
    • 0028825118 scopus 로고
    • The posterior stabilized total knee prosthesis: Assessment of polyethylene damage and osteolysis after 10-year followup
    • Colliza WA, Insall JN,Scuderi GR (1995) The posterior stabilized total knee prosthesis: Assessment of polyethylene damage and osteolysis after 10-year followup. J Bone Joint Surg Am 77:1713-1720
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1713-1720
    • Colliza, W.A.1    Insall, J.N.2    Scuderi, G.R.3
  • 9
    • 0033750997 scopus 로고    scopus 로고
    • Comparison between the kinematics of fixed and rotating bearing knee prostheses
    • D'Lima DD, Trice M, Urquhart AG, Colwell CW Jr (2000) Comparison between the kinematics of fixed and rotating bearing knee prostheses. Clin Orthop 380:151-157
    • (2000) Clin Orthop , vol.380 , pp. 151-157
    • D'Lima, D.D.1    Trice, M.2    Urquhart, A.G.3    Colwell C.W., Jr.4
  • 12
    • 0032746208 scopus 로고    scopus 로고
    • Total condylar knee arthroplasty. 16- to 21-year results
    • Gill GS,Joshi AB, Mills DM (1999) Total condylar knee arthroplasty. 16- to 21-year results. Clin Orthop 367: 210-215
    • (1999) Clin Orthop , vol.367 , pp. 210-215
    • Gill, G.S.1    Joshi, A.B.2    Mills, D.M.3
  • 13
    • 0022529498 scopus 로고
    • Clinical results of the Oxford Knee: Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis
    • Goodfellow JW, O'Connor J (1986) Clinical results of the Oxford Knee: Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. Clin Orthop 205:21-42
    • (1986) Clin Orthop , vol.205 , pp. 21-42
    • Goodfellow, J.W.1    O'Connor, J.2
  • 14
    • 0001388870 scopus 로고    scopus 로고
    • Meniscal-bearing knee replacement
    • Insall JN, Scott WN (eds). Churchill Livingstone, New York
    • Insall JN, Aglietti P, Baldini A, Easley ME (2001) Meniscal-bearing knee replacement. In: Insall JN, Scott WN (eds) Surgery of the knee, 3rd edn. Churchill Livingstone, New York, 1717-1738
    • (2001) Surgery of the Knee, 3rd Edn. , pp. 1717-1738
    • Insall, J.N.1    Aglietti, P.2    Baldini, A.3    Easley, M.E.4
  • 15
    • 0036187644 scopus 로고    scopus 로고
    • The clinical history of mobile-bearing patella components in total knee arthroplasty
    • Jordan LR, Dowd JE, Olivio JL, Voorhorst PE (2002) The clinical history of mobile-bearing patella components in total knee arthroplasty. Orthopedics 25: 247-250
    • (2002) Orthopedics , vol.25 , pp. 247-250
    • Jordan, L.R.1    Dowd, J.E.2    Olivio, J.L.3    Voorhorst, P.E.4
  • 17
    • 0035169051 scopus 로고    scopus 로고
    • Comparison of fixed bearing and mobile-bearing total knee arthroplasties
    • Kim YH, Kook HK, Kim JS (2001) Comparison of fixed bearing and mobile-bearing total knee arthroplasties. Clin Orthop 392:101-115
    • (2001) Clin Orthop , vol.392 , pp. 101-115
    • Kim, Y.H.1    Kook, H.K.2    Kim, J.S.3
  • 19
    • 0037641149 scopus 로고    scopus 로고
    • The effekts of articular geometry on delamination and pitting of UHMWPE tibial inserts: I. A finite element study
    • Morra EA, Postak PD, Greenwald AS (1997) The effekts of articular geometry on delamination and pitting of UHMWPE tibial inserts: I.A finite element study. Orthop Trans 20:66
    • (1997) Orthop Trans , vol.20 , pp. 66
    • Morra, E.A.1    Postak, P.D.2    Greenwald, A.S.3
  • 20
    • 0030341078 scopus 로고    scopus 로고
    • Theory and practice of meniscal knee replacement: Design against wear
    • O'Connor JJ, Goodfellow JW (1996) Theory and practice of meniscal knee replacement: Design against wear. Proc Inst Mech Eng (H) 210:217-222
    • (1996) Proc Inst Mech Eng (H) , vol.210 , pp. 217-222
    • O'Connor, J.J.1    Goodfellow, J.W.2
  • 21
    • 0032201263 scopus 로고    scopus 로고
    • Modular tibial insert micromotion. A concern with contemporary knee implants
    • Parks NL, Engh GA, Emperado J (1998) Modular tibial insert micromotion. A concern with contemporary knee implants. Clin Orthop 356:10-15
    • (1998) Clin Orthop , vol.356 , pp. 10-15
    • Parks, N.L.1    Engh, G.A.2    Emperado, J.3
  • 22
    • 0029899245 scopus 로고    scopus 로고
    • The rotaglide total knee arthroplasty, prothesis design and early results
    • Polyzoides AJ, Dendrinos GK, Tsakonas H (1996) The rotaglide total knee arthroplasty, prothesis design and early results. J Arthroplasty 11:453-459
    • (1996) J Arthroplasty , vol.11 , pp. 453-459
    • Polyzoides, A.J.1    Dendrinos, G.K.2    Tsakonas, H.3
  • 23
    • 0027478984 scopus 로고
    • Long-term results of the total condylar knee arthroplasty: A 15-year survivorship study
    • Ranawat CS, Flynn WF Jr, Saddler S, Hansraj KK, Maynard MJ (1993) Long-term results of the total condylar knee arthroplasty: A 15-year survivorship study. Clin Orthop 286:94-102
    • (1993) Clin Orthop , vol.286 , pp. 94-102
    • Ranawat, C.S.1    Flynn W.F., Jr.2    Saddler, S.3    Hansraj, K.K.4    Maynard, M.J.5
  • 24
    • 0034959851 scopus 로고    scopus 로고
    • Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement
    • Ritter MA, Berend ME, Meding JB, Keating EM, Faris P (2001) Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement. Clin Orthop 388:51-57
    • (2001) Clin Orthop , vol.388 , pp. 51-57
    • Ritter, M.A.1    Berend, M.E.2    Meding, J.B.3    Keating, E.M.4    Faris, P.5
  • 25
    • 0035727965 scopus 로고    scopus 로고
    • The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements
    • Sathasivam S, Walker PS, Campbell PA, Rayner K (2001) The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J Biomed Mater Res 58:282-290
    • (2001) J Biomed Mater Res , vol.58 , pp. 282-290
    • Sathasivam, S.1    Walker, P.S.2    Campbell, P.A.3    Rayner, K.4
  • 26
    • 0029788347 scopus 로고    scopus 로고
    • The rotating platform mobile bearing TKA
    • Sorrells RB (1996) The rotating platform mobile bearing TKA.Orthopedics 19:793-796
    • (1996) Orthopedics , vol.19 , pp. 793-796
    • Sorrells, R.B.1
  • 27
    • 0034876674 scopus 로고    scopus 로고
    • Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years
    • Sorrells RB, Stiehl JB, Voorhorst PE (2001) Midterm results of mobile-bearing total knee arthroplasty in patients younger than 65 years. Clin Orthop 390:182-189
    • (2001) Clin Orthop , vol.390 , pp. 182-189
    • Sorrells, R.B.1    Stiehl, J.B.2    Voorhorst, P.E.3
  • 28
    • 0031454021 scopus 로고    scopus 로고
    • In vivo kinematic analysis of a mobile bearing total knee prosthesis
    • Stiehl JB, Dennis DA, Komistek RD, Keblish PA (1997) In vivo kinematic analysis of a mobile bearing total knee prosthesis. Clin Orthop 354:60-66
    • (1997) Clin Orthop , vol.354 , pp. 60-66
    • Stiehl, J.B.1    Dennis, D.A.2    Komistek, R.D.3    Keblish, P.A.4
  • 29
    • 0036151848 scopus 로고    scopus 로고
    • Relative motion of a mobile bearing inlay after total knee arthroplasty - Dynamic in vitro study
    • Stukenborg-Colsman C, Ostermeier S, Wenger KH, Wirth C (2002) Relative motion of a mobile bearing inlay after total knee arthroplasty - dynamic in vitro study. Clin Biomech 17:49-55
    • (2002) Clin Biomech , vol.17 , pp. 49-55
    • Stukenborg-Colsman, C.1    Ostermeier, S.2    Wenger, K.H.3    Wirth, C.4
  • 30
    • 0027324619 scopus 로고
    • Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system
    • Weaver JK, Derklash RS, Greenwald AS (1993) Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system. Clin Orthop 290:244-252
    • (1993) Clin Orthop , vol.290 , pp. 244-252
    • Weaver, J.K.1    Derklash, R.S.2    Greenwald, A.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.