-
2
-
-
0032587945
-
Biomedical applications of polyurethanes: A review of past promises, present realities, and a vibrant future
-
Zdrahala RJ, Zdrahala IJ: Biomedical applications of polyurethanes: A review of past promises, present realities, and a vibrant future. J Biomater Appl 14: 67-90, 1999.
-
(1999)
J Biomater Appl
, vol.14
, pp. 67-90
-
-
Zdrahala, R.J.1
Zdrahala, I.J.2
-
3
-
-
0024100474
-
Biostability of polyurethane elastomers: A critical review
-
Szycher M: Biostability of polyurethane elastomers: A critical review. J Biomater Appl 3: 297-402, 1988.
-
(1988)
J Biomater Appl
, vol.3
, pp. 297-402
-
-
Szycher, M.1
-
4
-
-
2942673144
-
Clinical experience with a new peritoneal dialysis access device (the Cruz catheter)
-
Ota K, Maher J, Winchester J, Hirszel P (eds). Amsterdam: Excerpta Medica
-
Cruz C: Clinical experience with a new peritoneal dialysis access device (the Cruz catheter), in Ota K, Maher J, Winchester J, Hirszel P (eds), Current Concepts in Peritoneal Dialysis: Proceedings of the Fifth Congress of the International Society for Peritoneal Dialysis; 21-24 July 1990; Kyoto, Japan. Amsterdam: Excerpta Medica, 1992, pp. 164-169.
-
(1992)
Current Concepts in Peritoneal Dialysis: Proceedings of the Fifth Congress of the International Society for Peritoneal Dialysis; 21-24 July 1990; Kyoto, Japan
, pp. 164-169
-
-
Cruz, C.1
-
5
-
-
0344972800
-
Long-term experience with polyurethane, pail handle coiled tip peritoneal dialysis catheters
-
Crabtree JH, Siddiqi RA, Chung JJ, Greenwald LT; Long-term experience with polyurethane, pail handle coiled tip peritoneal dialysis catheters. ASAIO J 44: 309-313, 1998.
-
(1998)
ASAIO J
, vol.44
, pp. 309-313
-
-
Crabtree, J.H.1
Siddiqi, R.A.2
Chung, J.J.3
Greenwald, L.T.4
-
6
-
-
0033408436
-
The risk of infection and peritoneal catheter loss from implant procedure exit site trauma
-
Crabtree JH, Fishman A, Siddiqi RA, Hadnott LL: The risk of infection and peritoneal catheter loss from implant procedure exit site trauma. Perit Dial Int 19: 66-371, 1999,
-
(1999)
Perit Dial Int
, vol.19
, pp. 366-371
-
-
Crabtree, J.H.1
Fishman, A.2
Siddiqi, R.A.3
Hadnott, L.L.4
-
7
-
-
0030812665
-
The Cruz catheter and its functional characteristics
-
Cruz C: The Cruz catheter and its functional characteristics. Perit Dial Int 17(Suppl.): 146-148, 1997.
-
(1997)
Perit Dial Int
, vol.17
, Issue.SUPPL.
, pp. 146-148
-
-
Cruz, C.1
-
8
-
-
0002889880
-
Mupirocin (Bactroban) causes permanent structural changes in peritoneal dialysis catheters
-
Weaver ME, Dunbeck DC: Mupirocin (Bactroban) causes permanent structural changes in peritoneal dialysis catheters (Abstract). Perit Dial Int 14(Suppl.): 20, 1994.
-
(1994)
Perit Dial Int
, vol.14
, Issue.SUPPL.
, pp. 20
-
-
Weaver, M.E.1
Dunbeck, D.C.2
-
9
-
-
0030831611
-
Unusual complications of a polyurethane PD catheter
-
Rao SP, Oreopoulos DG: Unusual complications of a polyurethane PD catheter (Letter). Perit Dial Int 17: 410-412, 1997.
-
(1997)
Perit Dial Int
, vol.17
, pp. 410-412
-
-
Rao, S.P.1
Oreopoulos, D.G.2
-
10
-
-
0031801878
-
Spontaneous rupture of polyurethane peritoneal catheter: A possible deleterious effect of mupirocin ointment
-
Riu S, Ruiz CG, Martinez-Vea A, Peralta C, Oliver JA: Spontaneous rupture of polyurethane peritoneal catheter: A possible deleterious effect of mupirocin ointment. Nephrol Dial Transplant 13: 1870-1871, 1998.
-
(1998)
Nephrol Dial Transplant
, vol.13
, pp. 1870-1871
-
-
Riu, S.1
Ruiz, C.G.2
Martinez-Vea, A.3
Peralta, C.4
Oliver, J.A.5
-
12
-
-
0026689691
-
Sebaceous gland lipids
-
Stewart ME: Sebaceous gland lipids. Semin Dermatol 11: 100-105, 1992.
-
(1992)
Semin Dermatol
, vol.11
, pp. 100-105
-
-
Stewart, M.E.1
-
13
-
-
0031213712
-
In vivo biocompatibility and biostability of modified polyurethanes
-
Mathur AB, Collier TO, Kao WJ, et al: In vivo biocompatibility and biostability of modified polyurethanes. J Biomed Mater Res 36: 246-257, 1997.
-
(1997)
J Biomed Mater Res
, vol.36
, pp. 246-257
-
-
Mathur, A.B.1
Collier, T.O.2
Kao, W.J.3
-
14
-
-
0034771827
-
Effect of preventing Staphylococcus aureus carriage on rates of peritoneal catheter-related staphylococcal infections
-
Ritzau J, Hoffman RM, Tzamaloukas AH: Effect of preventing Staphylococcus aureus carriage on rates of peritoneal catheter-related staphylococcal infections. Literature Synthesis Perit Dial Int 21: 471-479, 2001.
-
(2001)
Literature Synthesis Perit Dial Int
, vol.21
, pp. 471-479
-
-
Ritzau, J.1
Hoffman, R.M.2
Tzamaloukas, A.H.3
-
15
-
-
0027624489
-
Polyurethane or silicone as long-term implant substance: A critical evaluation
-
Behrend D, Schmitz KP: Polyurethane or silicone as long-term implant substance: A critical evaluation. Biomed Tech 38: 172-178, 1993.
-
(1993)
Biomed Tech
, vol.38
, pp. 172-178
-
-
Behrend, D.1
Schmitz, K.P.2
-
16
-
-
0021132054
-
Biostability of medical elastomers: A review
-
Vondracek P, Dolezel B: Biostability of medical elastomers: A review. Biomaterials 5: 209-214, 1984.
-
(1984)
Biomaterials
, vol.5
, pp. 209-214
-
-
Vondracek, P.1
Dolezel, B.2
-
18
-
-
0033770296
-
Trends in patient and technique survival in peritoneal dialysis and strategies: How are we doing and how can we do better?
-
Blake PG: Trends in patient and technique survival in peritoneal dialysis and strategies: How are we doing and how can we do better? Adv Ren Replace Ther 7: 324-337, 2000.
-
(2000)
Adv Ren Replace Ther
, vol.7
, pp. 324-337
-
-
Blake, P.G.1
|