메뉴 건너뛰기




Volumn 17, Issue SUPPL. 2, 1997, Pages

The Cruz catheter and its functional characteristics

Author keywords

Cruz catheter; Dialysis efficiency; Flow dynamics; Peritoneal access; Silicone catheter

Indexed keywords

POLYMER; POLYURETHAN;

EID: 0030812665     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686089701702s29     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 0002840769 scopus 로고
    • Peritoneal access devices
    • Allen R, ed. Nissenson Norwalk, Connecticut: Appleton and Lange
    • Ash S, Carr DJ, Diaz-Buxo JA. Peritoneal access devices. In: Allen R, ed. Clinical Dialysis (2nd ed.) Nissenson Norwalk, Connecticut: Appleton and Lange 1990.
    • (1990) Clinical Dialysis (2nd Ed.)
    • Ash, S.1    Carr, D.J.2    Diaz-Buxo, J.A.3
  • 2
    • 2942673144 scopus 로고
    • Clinical experience with a new peritoneal dialysis access device (the Cruz™ Catheter)
    • Cruz C. Clinical experience with a new peritoneal dialysis access device (the Cruz™ Catheter). Current Concepts in Peritoneal Dialysis 1992; 164-9.
    • (1992) Current Concepts in Peritoneal Dialysis , pp. 164-169
    • Cruz, C.1
  • 3
    • 50549204069 scopus 로고
    • Prolonged peritoneal dialysis for chronic renal failure
    • Palmer RA, Quinton W, Gray JE. Prolonged peritoneal dialysis for chronic renal failure. Lancet 1964; 1:700-2.
    • (1964) Lancet , vol.1 , pp. 700-702
    • Palmer, R.A.1    Quinton, W.2    Gray, J.E.3
  • 4
    • 0014384927 scopus 로고
    • A bacteriologically safe peritoneal access device
    • Tenckhoff H, Schlechter H. A bacteriologically safe peritoneal access device. ASAIO Trans 1968; 14:181-5.
    • (1968) ASAIO Trans , vol.14 , pp. 181-185
    • Tenckhoff, H.1    Schlechter, H.2
  • 5
    • 84979336541 scopus 로고
    • Are the new peritoneal dialysis catheters better than the Tenckhoff catheter?
    • Cruz C. Are the new peritoneal dialysis catheters better than the Tenckhoff catheter? Semm Dial 1992; 5(3):202-4.
    • (1992) Semm Dial , vol.5 , Issue.3 , pp. 202-204
    • Cruz, C.1
  • 6
    • 0000461533 scopus 로고
    • Plastics technology
    • Bilmeyer FW, ed. New York: John Wiley and Sons
    • Bilmeyer FW. Plastics technology. In: Bilmeyer FW, ed. Textbook of Polymer Science (3rd ed.) New York: John Wiley and Sons, 1984; 457-85.
    • (1984) Textbook of Polymer Science (3rd Ed.) , pp. 457-485
    • Bilmeyer, F.W.1
  • 7
    • 0345174650 scopus 로고
    • Flow dynamics in peritoneal dialysis: The search for optimal CAPD systems
    • Cruz C, Bonilla H, Melendez A, Faber MD, Dumler F. Flow dynamics in peritoneal dialysis: The search for optimal CAPD systems (Abstract). Perit Dial Int 1991; 11 (Suppl 1):54.
    • (1991) Perit Dial Int , vol.11 , Issue.1 SUPPL. , pp. 54
    • Cruz, C.1    Bonilla, H.2    Melendez, A.3    Faber, M.D.4    Dumler, F.5
  • 8
    • 9844224345 scopus 로고
    • High flow peritoneal dialysis
    • Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Toronto: Peritoneal Dialysis Publications Inc.
    • Montenegro J, Gonzales O, Saracho R. High flow peritoneal dialysis. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Advances in Peritoneal Dialysis Toronto: Peritoneal Dialysis Publications Inc., 1994.
    • (1994) Advances in Peritoneal Dialysis
    • Montenegro, J.1    Gonzales, O.2    Saracho, R.3
  • 9
    • 9844267819 scopus 로고
    • Enhanced dialysis delivery with PD Plus
    • Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Toronto: Peritoneal Dialysis Publications Inc.
    • Cruz C, Dumler F, Schmidt R, et al. Enhanced dialysis delivery with PD Plus. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG, eds. Advances in Peritoneal Dialysis Toronto: Peritoneal Dialysis Publications Inc., 1992; 8:105-7.
    • (1992) Advances in Peritoneal Dialysis , vol.8 , pp. 105-107
    • Cruz, C.1    Dumler, F.2    Schmidt, R.3