메뉴 건너뛰기




Volumn 267, Issue 2, 2002, Pages 85-89

Spinal anesthesia hypotension in elective cesarean section in parturients wearing extra-strong compression stockings

Author keywords

Bupivacaine; Cesarean section; Compression stocking; Dibucaine; Spinal anesthesia

Indexed keywords

BUPIVACAINE; CINCHOCAINE; EPHEDRINE;

EID: 0037834851     PISSN: 09320067     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00404-001-0281-4     Document Type: Article
Times cited : (8)

References (26)
  • 1
    • 0025696480 scopus 로고
    • Prevention of hypotension following spinal anaesthesia for elective caesarean section by wrapping of the legs
    • Bhagwanjee S, Rocke DA, Rout CC, Koovarjee RV, Brijball R (1990) Prevention of hypotension following spinal anaesthesia for elective caesarean section by wrapping of the legs. Br J Anaesth 65:819-822
    • (1990) Br J Anaesth , vol.65 , pp. 819-822
    • Bhagwanjee, S.1    Rocke, D.A.2    Rout, C.C.3    Koovarjee, R.V.4    Brijball, R.5
  • 2
    • 0030924591 scopus 로고    scopus 로고
    • Prevention of hypotension during spinal anaesthesia for caesarean section: Ephedrine infusion versus fluid preload
    • Chan WS, Irwin MG, Tong WN, Lam YH (1997) Prevention of hypotension during spinal anaesthesia for caesarean section: ephedrine infusion versus fluid preload. Anaesthesia 52:908-913
    • (1997) Anaesthesia , vol.52 , pp. 908-913
    • Chan, W.S.1    Irwin, M.G.2    Tong, W.N.3    Lam, Y.H.4
  • 3
    • 0021277640 scopus 로고
    • Subarachnoid blockade with bupivacaine: A comparison with cinchocaine
    • Cummings GC, Bamber DB, Edstrom HH, Rubin AP (1984) Subarachnoid blockade with bupivacaine: a comparison with cinchocaine. Br J Anaesth 56:573-579
    • (1984) Br J Anaesth , vol.56 , pp. 573-579
    • Cummings, G.C.1    Bamber, D.B.2    Edstrom, H.H.3    Rubin, A.P.4
  • 4
    • 0029078992 scopus 로고
    • Anatomical configuration of the spinal column in the supine position: I. A study using magnetic resonance imaging
    • Hirabayashi Y, Shimizu R, Saitoh K, Fukuda H, Furuse M (1995) Anatomical configuration of the spinal column in the supine position: I. a study using magnetic resonance imaging. Br J Anaesth 75:3-5
    • (1995) Br J Anaesth , vol.75 , pp. 3-5
    • Hirabayashi, Y.1    Shimizu, R.2    Saitoh, K.3    Fukuda, H.4    Furuse, M.5
  • 5
    • 0029078993 scopus 로고
    • Anatomical configuration of the spinal column in the supine position: II. Comparison of pregnant and non-pregnant women
    • Hirabayashi Y, Shimizu R, Fukuda H, Saitoh K, Furuse M (1995) Anatomical configuration of the spinal column in the supine position: II. comparison of pregnant and non-pregnant women. Br J Anaesth 75:6-8
    • (1995) Br J Anaesth , vol.75 , pp. 6-8
    • Hirabayashi, Y.1    Shimizu, R.2    Fukuda, H.3    Saitoh, K.4    Furuse, M.5
  • 6
    • 0022517198 scopus 로고
    • Spinal anaesthesia for obstetrics
    • Hunt CO, Rubin AP (1986) Spinal anaesthesia for obstetrics. Clin Anaesthesiol 4:135-143
    • (1986) Clin Anaesthesiol , vol.4 , pp. 135-143
    • Hunt, C.O.1    Rubin, A.P.2
  • 7
    • 0028853760 scopus 로고
    • The effects of graduated compression stocking on blood pressure and heart rate during spinal or epidural anesthesia
    • Iwama H (1995) The effects of graduated compression stocking on blood pressure and heart rate during spinal or epidural anesthesia. J Anesth 9:383-384
    • (1995) J Anesth , vol.9 , pp. 383-384
    • Iwama, H.1
  • 8
    • 0029786444 scopus 로고    scopus 로고
    • Graduated compression stocking prevents hypotension during spinal anaesthesia
    • Iwama H (1996) Graduated compression stocking prevents hypotension during spinal anaesthesia. Can J Anaesth 43:984-985
    • (1996) Can J Anaesth , vol.43 , pp. 984-985
    • Iwama, H.1
  • 9
    • 0034535715 scopus 로고    scopus 로고
    • Limited spread of spinal anesthesia using a hyperbaric local anesthetic in older patients
    • Iwama H, Ohmori S (2001) Limited spread of spinal anesthesia using a hyperbaric local anesthetic in older patients. J Anesth 14:227-228
    • (2001) J Anesth , vol.14 , pp. 227-228
    • Iwama, H.1    Ohmori, S.2
  • 10
    • 0035002366 scopus 로고    scopus 로고
    • Extra strong graduated compression stocking reduces usage of vasopressor agents during spinal anesthesia for cesarean section
    • Iwama H, Furuta S, Tanigawa S, Ohmizo H, Ohmori S, Kaneko T (2001) Extra strong graduated compression stocking reduces usage of vasopressor agents during spinal anesthesia for cesarean section. Arch Gynecol Obstet 265:60-63
    • (2001) Arch Gynecol Obstet , vol.265 , pp. 60-63
    • Iwama, H.1    Furuta, S.2    Tanigawa, S.3    Ohmizo, H.4    Ohmori, S.5    Kaneko, T.6
  • 11
    • 0030579649 scopus 로고    scopus 로고
    • Compression stockings as prevention of hypotension in Cesarean section during spinal anesthesia
    • Jorgensen J, Christensen PK, Sonnenschein CH (1996) Compression stockings as prevention of hypotension in Cesarean section during spinal anesthesia (in Danish with English abstract). Ugeskr Laeger 158:1526-1529
    • (1996) Ugeskr Laeger , vol.158 , pp. 1526-1529
    • Jorgensen, J.1    Christensen, P.K.2    Sonnenschein, C.H.3
  • 12
    • 0034040317 scopus 로고    scopus 로고
    • A dose-response study of prophylactic intravenous ephedrine for the prevention of hypotension during spinal anesthesia for cesarean delivery
    • Kee WD, Khaw KS, Lee BB, Lau TK, Gin T (2000) A dose-response study of prophylactic intravenous ephedrine for the prevention of hypotension during spinal anesthesia for cesarean delivery. Anesth Analg 90:1390-1395
    • (2000) Anesth Analg , vol.90 , pp. 1390-1395
    • Kee, W.D.1    Khaw, K.S.2    Lee, B.B.3    Lau, T.K.4    Gin, T.5
  • 13
    • 0025831336 scopus 로고
    • Influence of the lumbar interspace chosen for injection on the spread of hyperbaric 0.5% bupivacaine
    • Lowson SM, Brown J, Wilkins CJ (1991) Influence of the lumbar interspace chosen for injection on the spread of hyperbaric 0.5% bupivacaine. Br J Anaesth 66:465-468
    • (1991) Br J Anaesth , vol.66 , pp. 465-468
    • Lowson, S.M.1    Brown, J.2    Wilkins, C.J.3
  • 14
    • 0023885769 scopus 로고
    • Subarachnoid anaesthesia for elective Caesarean section: A comparison of two hyperbaric solutions
    • Michie AR, Freeman RM, Dutton DA, Howie HB (1988) Subarachnoid anaesthesia for elective Caesarean section: a comparison of two hyperbaric solutions. Anaesthesia 43:96-99
    • (1988) Anaesthesia , vol.43 , pp. 96-99
    • Michie, A.R.1    Freeman, R.M.2    Dutton, D.A.3    Howie, H.B.4
  • 15
    • 0035079897 scopus 로고    scopus 로고
    • The effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: A qualitative systematic review
    • Morgan PJ, Halpern SH, Tarshis J (2001) The effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: a qualitative systematic review. Anesth Analg 92:997-1005
    • (2001) Anesth Analg , vol.92 , pp. 997-1005
    • Morgan, P.J.1    Halpern, S.H.2    Tarshis, J.3
  • 16
    • 0025215134 scopus 로고
    • Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient
    • Norris MC (1990) Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient. Anesthesiology 72:478-482
    • (1990) Anesthesiology , vol.72 , pp. 478-482
    • Norris, M.C.1
  • 18
    • 0025020659 scopus 로고
    • Maternal opinion about analgesia in labor and delivery: A comparison of epidural blockade and intramuscular pethidine
    • Philipsen T, Jensen NH (1990) Maternal opinion about analgesia in labor and delivery: a comparison of epidural blockade and intramuscular pethidine. Eur J Obstet Gynecol Reprod Biol 34:205-210
    • (1990) Eur J Obstet Gynecol Reprod Biol , vol.34 , pp. 205-210
    • Philipsen, T.1    Jensen, N.H.2
  • 20
    • 0027285197 scopus 로고
    • Leg elevation and wrapping in the prevention of hypotension following spinal anaesthesia for elective caesarean section
    • Rout CC, Rocke DA, Gouws E (1993) Leg elevation and wrapping in the prevention of hypotension following spinal anaesthesia for elective caesarean section. Anaesthesia 48: 304-308
    • (1993) Anaesthesia , vol.48 , pp. 304-308
    • Rout, C.C.1    Rocke, D.A.2    Gouws, E.3
  • 21
    • 0023102628 scopus 로고
    • Subarachnoid analgesia for caesarean section: A double-blind comparison of plain and hyperbaric 0.5% bupivacaine
    • Russell IF, Holmqvist ELO (1987) Subarachnoid analgesia for caesarean section: a double-blind comparison of plain and hyperbaric 0.5% bupivacaine. Br J Anaesth 59:347-353
    • (1987) Br J Anaesth , vol.59 , pp. 347-353
    • Russell, I.F.1    Holmqvist, E.L.O.2
  • 23
    • 0033844325 scopus 로고    scopus 로고
    • Hydroxyethylstarch 10% is superior to Ringer's solution for preloading before spinal anesthesia for Cesarean section
    • Siddik SM, Aouad MT, Kai GE, Sfeir MM, Baraka AS (2000) Hydroxyethylstarch 10% is superior to Ringer's solution for preloading before spinal anesthesia for Cesarean section. Can J Anaesth 47:616-621
    • (2000) Can J Anaesth , vol.47 , pp. 616-621
    • Siddik, S.M.1    Aouad, M.T.2    Kai, G.E.3    Sfeir, M.M.4    Baraka, A.S.5
  • 24
    • 0031944062 scopus 로고    scopus 로고
    • Clinical study of AJ-007 (bupivacaine) in spinal anesthesia: Investigation of clinical dosage of isobaric and hyperbaric formulations
    • Suzuki H, Ogawa S, Hanaoka K, Kugimiya T, Yokoyama K, Isshiki A, Hosoyamada A, Kikuchi H, Numata K (1998) Clinical study of AJ-007 (bupivacaine) in spinal anesthesia: investigation of clinical dosage of isobaric and hyperbaric formulations (in Japanese with English abstract). Masui (Jpn J Anesthesiol) 47:447-465
    • (1998) Masui (Jpn J Anesthesiol) , vol.47 , pp. 447-465
    • Suzuki, H.1    Ogawa, S.2    Hanaoka, K.3    Kugimiya, T.4    Yokoyama, K.5    Isshiki, A.6    Hosoyamada, A.7    Kikuchi, H.8    Numata, K.9
  • 25
    • 0032740363 scopus 로고    scopus 로고
    • Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective Cesarean section
    • Ueyama H, He YL, Tanigami H, Mashimo T, Yoshiya I (1999) Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective Cesarean section. Anesthesiology 91:1571-1576
    • (1999) Anesthesiology , vol.91 , pp. 1571-1576
    • Ueyama, H.1    He, Y.L.2    Tanigami, H.3    Mashimo, T.4    Yoshiya, I.5
  • 26
    • 0032104209 scopus 로고    scopus 로고
    • Prevention of post-spinal hypotension at elective cesarean section by wrapping of the lower limbs
    • van Bogaert LJ (1998) Prevention of post-spinal hypotension at elective cesarean section by wrapping of the lower limbs. Int J Gynaecol Obstet 61:233-238
    • (1998) Int J Gynaecol Obstet , vol.61 , pp. 233-238
    • Van Bogaert, L.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.