메뉴 건너뛰기




Volumn , Issue , 2003, Pages 95-102

Applicability of resistance and temperature measurements for the characterization of full tension compression splices

(2)  Comte, C a   Lacasse, R a  

a NONE

Author keywords

Electrical resistance measurement; On line inspection; Overhead transmission line; Splice; Temperature measurement; Thermography

Indexed keywords

ELECTRIC UTILITIES; INSPECTION; RELIABILITY; TEMPERATURE MEASUREMENT; THERMAL EXPANSION;

EID: 0037817410     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (16)
  • 2
    • 85009040217 scopus 로고    scopus 로고
    • Hotline inspection and control of joint
    • Vattenfall Transmission AB, Sweden
    • J. Ormin, J. Bartsch, Vattenfall Transmission AB, Sweden, "Hotline inspection and control of joint," CIGRÉ 22-203, session 1998.
    • CIGRÉ 22-203, Session 1998
    • Ormin, J.1    Bartsch, J.2
  • 4
    • 25744474968 scopus 로고    scopus 로고
    • Conductors, overhead ground wires and joints
    • Ontario Hydro Service Company; Session 7, paper 5
    • D.C. Bellows, Ontario Hydro Service Company, "Conductors, Overhead ground wires and joints," 1999. Session 7, paper 5.
    • (1999)
    • Bellows, D.C.1
  • 5
    • 0038692398 scopus 로고    scopus 로고
    • Preventive and predictive maintenance using infrared camera and measurement resistance connector
    • Georgia Power USA
    • W.S. Grondahl, Georgia Power USA. "Preventive and predictive Maintenance Using Infrared Camera and Measurement Resistance Connector," Thermal Solution ®, 2002.
    • (2002) Thermal Solution ®
    • Grondahl, W.S.1
  • 6
    • 0038692396 scopus 로고    scopus 로고
    • IR diagnostic of joints in electrical power engineering using the RELITE method
    • D. Fricke, R.D. Rogler. "IR Diagnostic of Joints in Electrical Power Engineering Using the RELITE Method," 2002.
    • (2002)
    • Fricke, D.1    Rogler, R.D.2
  • 7
    • 25744480024 scopus 로고    scopus 로고
    • Transmission line conductor joint resistance's measured live line
    • New Zeland; Website.doc
    • W.D. Marshall, T.E. Jacobs, New Zeland, "Transmission Line Conductor Joint Resistance's Measured Live Line," 1997, Website.doc.
    • (1997)
    • Marshall, W.D.1    Jacobs, T.E.2
  • 8
    • 85009037016 scopus 로고    scopus 로고
    • ITC course manual
    • Inframetric Training Center, USA
    • Inframetric Training Center, USA. "ITC course manual."
  • 9
    • 4243575716 scopus 로고
    • Vérification des manchons comprimés
    • AP-LA-M210. Hydro-Québec
    • AP-LA-M210. Hydro-Québec, "Vérification des manchons comprimés," 1990.
    • (1990)
  • 10
    • 85009040219 scopus 로고    scopus 로고
    • Do you know the condition of your splices?
    • SensorNote (Ohmstick); Note 304
    • J. Renowden, SensorNote (Ohmstick), "Do you know the condition of your splices?,"
    • Renowden, J.1
  • 12
    • 4243496502 scopus 로고    scopus 로고
    • An effective resistance measurement technique for improving the current-cycling test of power connectors
    • © IEEE
    • Chinh Dang, M. Braunovic, "An effective resistance measurement technique for improving the current-cycling test of power connectors," © IEEE, 1999.
    • (1999)
    • Dang, C.1    Braunovic, M.2
  • 13
    • 0032679711 scopus 로고    scopus 로고
    • Emissivity measurement and temperature correction accuracy considerations
    • R.P. Madding, "Emissivity measurement and temperature correction accuracy considerations," Thermosense XXI, SPIE Proceedings Vol. 3700, pp. 393-401, 1999.
    • (1999) Thermosense XXI, SPIE Proceedings , vol.3700 , pp. 393-401
    • Madding, R.P.1
  • 14
    • 0038015932 scopus 로고    scopus 로고
    • Electric power connectors for use in overhead line conductors
    • CAN/CSA C57-98; March 1998
    • CAN/CSA C57-98, "Electric Power Connectors for use in Overhead Line Conductors," March 1998.
    • (1998)
  • 15
    • 0003598492 scopus 로고    scopus 로고
    • Common sense approach to thermal imaging
    • SPIE Optical Engineering Press
    • G.C. Holst, "Common sense approach to thermal imaging," SPIE Optical Engineering Press, 2000.
    • (2000)
    • Holst, G.C.1
  • 16
    • 70449335406 scopus 로고    scopus 로고
    • Standard for calculating the current-temperature relationship of bare overhead conductors
    • IEEE; IEEE Std 738-1993
    • IEEE. "Standard for calculating the current-temperature relationship of bare overhead conductors," IEEE Std 738-1993.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.