Volumn 16, Issue 2, 2003, Pages 88-92

Microdamage at the pin-bone interface of external skeletal fixation pins after short-term cyclical loading ex-vivo

Author keywords

Cyclical loading; External fixation pin; Microdomage

Indexed keywords

FUCHSINE;

EID: 0037797344     PISSN: 09320814     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1632765     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0027435284 scopus 로고
    • Cortical bone reactions at the interface of external fixation half-pins under different loading conditions
    • Aro HT, Markel MD, Chao EYS. Cortical bone reactions at the interface of external fixation half-pins under different loading conditions. J Trauma 1993; 35: 776-85.
    • (1993) J Trauma , vol.35 , pp. 776-785
    • Aro, H.T.1    Markel, M.D.2    Chao, E.Y.S.3
  • 2
    • 0031719754 scopus 로고    scopus 로고
    • Intracortical remodeling in adult rat long bones after fatigue loading
    • Bentolila V, Boyce TM, Fyhrie DR et al. Intracortical remodeling in adult rat long bones after fatigue loading. Bone 1998; 23: 275-81.
    • (1998) Bone , vol.23 , pp. 275-281
    • Bentolila, V.1    Boyce, T.M.2    Fyhrie, D.R.3
  • 3
    • 0028789334 scopus 로고
    • Alterations to the en bloc basic fuchsin staining protocol for the demonstration of microdamage produced in vivo
    • Burr DB, Hooser M. Alterations to the en bloc basic fuchsin staining protocol for the demonstration of microdamage produced in vivo. Bone 1995; 17: 431-3.
    • (1995) Bone , vol.17 , pp. 431-433
    • Burr, D.B.1    Hooser, M.2
  • 4
    • 0028889253 scopus 로고
    • The design and performance of an experimental external fixation device with load trans-ducers
    • Draper ERC, Wallace AL, Strachen RK, et al. The design and performance of an experimental external fixation device with load trans-ducers. Med Eng Phys 1995; 17: 618-24.
    • (1995) Med Eng Phys , vol.17 , pp. 618-624
    • Draper, E.R.C.1    Wallace, A.L.2    Strachen, R.K.3
  • 5
    • 0029199230 scopus 로고
    • Geometrical propreties of the ovine tibia: A suitable animal model to study the pin-bone interface in fracture fixation?
    • Finlay JB, Hurtig MB, Hardie WR, Liggins AB, Batte SWR Geometrical propreties of the ovine tibia: a suitable animal model to study the pin-bone interface in fracture fixation? Proc Inst Mech Eng [H] 1995; 209: 37-50.
    • (1995) Proc Inst Mech Eng [H] , vol.209 , pp. 37-50
    • Finlay, J.B.1    Hurtig, M.B.2    Hardie, W.R.3    Liggins, A.B.4    Batte, S.W.R.5
  • 6
    • 0021059815 scopus 로고
    • Complications of external skeletal fixation
    • Green SA. Complications of external skeletal fixation. Clin Orthop Rel Res 1983; 180: 109-16.
    • (1983) Clin Orthop Rel Res , vol.180 , pp. 109-116
    • Green, S.A.1
  • 8
    • 0033053640 scopus 로고    scopus 로고
    • Microdamage adjacent to endosseus implants
    • Huja SS, Katona TR, Burr DB, et al. Microdamage adjacent to endosseus implants. Bone 1999; 25: 217-22.
    • (1999) Bone , vol.25 , pp. 217-222
    • Huja, S.S.1    Katona, T.R.2    Burr, D.B.3
  • 9
    • 0026303782 scopus 로고
    • Induction and prevention of pin loosening in external fixation: An in vivo study on sheep tibiae
    • Hyldahl C, Pearson S, Tepic S, Perren SM. Induction and prevention of pin loosening in external fixation: An in vivo study on sheep tibiae. J Orthop Trauma 1991; 5: 485-92.
    • (1991) J Orthop Trauma , vol.5 , pp. 485-492
    • Hyldahl, C.1    Pearson, S.2    Tepic, S.3    Perren, S.M.4
  • 10
    • 0031926127 scopus 로고    scopus 로고
    • A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins
    • Moroni A, Toksvig-Larsen S, Maltarello MC et al. A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins. J Bone Joint Surg [Am] 1998; 80: 547-54.
    • (1998) J Bone Joint Surg [Am] , vol.80 , pp. 547-554
    • Moroni, A.1    Toksvig-Larsen, S.2    Maltarello, M.C.3
  • 11
    • 0029135259 scopus 로고
    • Thermal response and torque resistance of five cortical half-pins under stimulated insertion technique
    • Wikenheiser MA, Markel MD, Lewallen DG, Chao EYS. Thermal response and torque resistance of five cortical half-pins under stimulated insertion technique. J Orthop Res 1995; 13: 615-9.
    • (1995) J Orthop Res , vol.13 , pp. 615-619
    • Wikenheiser, M.A.1    Markel, M.D.2    Lewallen, D.G.3    Chao, E.Y.S.4
  • 12
    • 0037651790 scopus 로고
    • The effect of external fixator pin geometry and dynamic loading on bone remodelling at the pin-bone interface (PBI), in an in vivo sheep tibia model
    • Zaruby JF, Hurtig MB, Finlay JB, Valliant AE. The effect of external fixator pin geometry and dynamic loading on bone remodelling at the pin-bone interface (PBI), in an in vivo sheep tibia model. Vet Corn Orthop Traumat 1995; 8: 9-19.
    • (1995) Vet Corn Orthop Traumat , vol.8 , pp. 9-19
    • Zaruby, J.F.1    Hurtig, M.B.2    Finlay, J.B.3    Valliant, A.E.4
  • 13
    • 0038666047 scopus 로고
    • Studies on the external fixator pin-bone interface: The effect of pin design and pin cooling in an in vivo sheep tibia model
    • Zaruby JF, Hurtig MB, Finlay JB, Valliant AE. Studies on the external fixator pin-bone interface: The effect of pin design and pin cooling in an in vivo sheep tibia model. Vet Com Orthop Traumat 1995; 8: 20-31.
    • (1995) Vet Com Orthop Traumat , vol.8 , pp. 20-31
    • Zaruby, J.F.1    Hurtig, M.B.2    Finlay, J.B.3    Valliant, A.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.