Volumn 141, Issue 3, 2003, Pages 309-315

Long-term results with the cemetless CLS stem in hip replacement;Langzeitresultate des unzementierten CLS-schaftes in der hüftendoprothetik

Author keywords

CLS stem; Heterotopic ossifications; Long term results; Radiolucency

Indexed keywords

CEMENT; POLYETHYLENE;

EID: 0037625394     PISSN: 00443220     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-40080     Document Type: Article
Times cited : (7)

References (30)
  • 1
    • 0028857458 scopus 로고
    • Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register
    • Havelin LI, Espehaug B, Vollset SE, Engesaeter LB. Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register. J Bone Joint Surg Br 1995; 77: 11-17
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 11-17
    • Havelin, L.I.1    Espehaug, B.2    Vollset, S.E.3    Engesaeter, L.B.4
  • 2
    • 0025157353 scopus 로고
    • Reflections on a small series of cementless total hip prostheses
    • Troussel S, van Innis F, Thys R. Reflections on a small series of cementless total hip prostheses. Acta Orthop Belg 1990; 56: 455-462
    • (1990) Acta Orthop Belg , vol.56 , pp. 455-462
    • Troussel, S.1    Van Innis, F.2    Thys, R.3
  • 6
    • 0028220083 scopus 로고
    • Hip arthroplasty using the cementless CLS stem. A 2-4-year experience
    • Robinson RP, Lovell TP, Green TM. Hip arthroplasty using the cementless CLS stem. A 2-4-year experience. J Arthroplasty 1994; 9: 177-192
    • (1994) J Arthroplasty , vol.9 , pp. 177-192
    • Robinson, R.P.1    Lovell, T.P.2    Green, T.M.3
  • 7
    • 0029994665 scopus 로고    scopus 로고
    • Uncemented total hip arthroplasty using the CLS stem: A titanium alloy implant with a corundum blast finish. Results at a mean 6 years in a prospective study
    • Robinson RP, Deysine GR, Green TM. Uncemented total hip arthroplasty using the CLS stem: a titanium alloy implant with a corundum blast finish. Results at a mean 6 years in a prospective study. J Arthroplasty 1996; 11: 286-292
    • (1996) J Arthroplasty , vol.11 , pp. 286-292
    • Robinson, R.P.1    Deysine, G.R.2    Green, T.M.3
  • 9
    • 0033939276 scopus 로고    scopus 로고
    • Total hip arthroplasty using an uncemented femoral component with taper design: Outcome at 10-year follow-up
    • Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg 2000; 120: 407-412
    • (2000) Arch Orthop Trauma Surg , vol.120 , pp. 407-412
    • Schramm, M.1    Keck, F.2    Hohmann, D.3    Pitto, R.P.4
  • 10
    • 0036955710 scopus 로고    scopus 로고
    • Einfluss der implantatiponsposition einer hüftendoprothese auf die standzeit am beispieldes CLS-schaftes
    • Schneider U, Breusch SJ, Thomsen M, Wirtz DC, Lukoschek M. Einfluss der Implantatiponsposition einer Hüftendoprothese auf die Standzeit am Beispieldes CLS-Schaftes. Unfallchirurg 2002; 105: 31-35
    • (2002) Unfallchirurg , vol.105 , pp. 31-35
    • Schneider, U.1    Breusch, S.J.2    Thomsen, M.3    Wirtz, D.C.4    Lukoschek, M.5
  • 11
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 1969; 51: 737-755
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 13
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979: 17-27
    • (1979) Clin Orthop , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 14
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976: 20-32
    • (1976) Clin Orthop , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 15
    • 0029588222 scopus 로고
    • 10 Jahre zementfreie implantation hüfttotalendoprothesen unter verwendung des zweymüllerschaftes
    • Zenz P, Pospisil C, Fertschak W, Schwagerl W. 10 Jahre zementfreie Implantation Hüfttotalendoprothesen unter Verwendung des Zweymüllerschaftes. ZOrthop Ihre Grenzgeb 1995; 133: 558-561
    • (1995) ZOrthop Ihre Grenzgeb , vol.133 , pp. 558-561
    • Zenz, P.1    Pospisil, C.2    Fertschak, W.3    Schwagerl, W.4
  • 16
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement. Incidence and a method of classification
    • Brooker AF, Bowerman JW, Robinson RA, Riley Jr LH. Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am 1973; 55: 1629-1632
    • (1973) J Bone Joint Surg Am , vol.55 , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley L.H., Jr.4
  • 17
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observation
    • Kaplan EL, Meier P. Nonparametric estimation from incomplete observation. Am Stat Ass J 1958; 53: 457-481
    • (1958) Am Stat Ass J , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, P.2
  • 18
    • 0033088786 scopus 로고    scopus 로고
    • Proximale verankerung von hüft-endoprothesen mit poröser oberfläche: 6-Jahres-ergebnisse
    • Decking J, Rosendahl T, Decking D. Proximale Verankerung von Hüft-Endoprothesen mit poröser Oberfläche: 6-Jahres-Ergebnisse. Z Orthop Ihre Grenzgeb 1999; 137: 108-113
    • (1999) Z Orthop Ihre Grenzgeb , vol.137 , pp. 108-113
    • Decking, J.1    Rosendahl, T.2    Decking, D.3
  • 19
    • 0031543692 scopus 로고    scopus 로고
    • Unsatisfactory results of a first-generation modular femoral stem implanted without cement. A 4- to 9-year follow-up study
    • Huo MH, Fye MA, Martin RP, Zatorski LE, Keggi KJ. Unsatisfactory results of a first-generation modular femoral stem implanted without cement. A 4- to 9-year follow-up study. J Arthroplasty 1997; 12: 490-496
    • (1997) J Arthroplasty , vol.12 , pp. 490-496
    • Huo, M.H.1    Fye, M.A.2    Martin, R.P.3    Zatorski, L.E.4    Keggi, K.J.5
  • 20
    • 0023946442 scopus 로고
    • The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series
    • Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Joint Surg Am 1988; 70: 337-346
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 337-346
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 21
    • 0028607993 scopus 로고
    • Clinical and roentgenographic results of cementless total hip arthroplasty
    • Lautiainen IA, Joukainen J, Makela EA. Clinical and roentgenographic results of cementless total hip arthroplasty. J Arthroplasty 1994; 9: 653-660
    • (1994) J Arthroplasty , vol.9 , pp. 653-660
    • Lautiainen, I.A.1    Joukainen, J.2    Makela, E.A.3
  • 22
    • 0027722678 scopus 로고
    • Le composant femoral non nimente CLS: Etude de 179 cas avec un recul de 2 a 5 ans
    • Rondia J, Albassir A, Litt R, Lemaire R. Le composant femoral non nimente CLS: etude de 179 cas avec un recul de 2 a 5 ans. Acta Orthop Belg 1993; 59 (Suppl 1 ): 289-293
    • (1993) Acta Orthop Belg , vol.59 , Issue.SUPPL. 1 , pp. 289-293
    • Rondia, J.1    Albassir, A.2    Litt, R.3    Lemaire, R.4
  • 23
    • 0034457299 scopus 로고    scopus 로고
    • 10-Jahres-ergebnisse mit einem zementierten feingestrahlten titan-aluminium-vanadium-hüftendoprothesenschaft
    • Hinrichs F, Boudriot U, Griss P. 10-Jahres-Ergebnisse mit einem zementierten feingestrahlten Titan-Aluminium-Vanadium-Hüftendoprothesenschaft. Z Orthop Ihre Grenzgeb 2000; 138: 52-56
    • (2000) Z Orthop Ihre Grenzgeb , vol.138 , pp. 52-56
    • Hinrichs, F.1    Boudriot, U.2    Griss, P.3
  • 24
    • 0025886244 scopus 로고
    • Total hip replacement with cemented, uncemented, and hybrid prostheses. A comparison of clinical and radiographic results at two to four years
    • Wixson RL, Stulberg SD, Mehlhoff M. Total hip replacement with cemented, uncemented, and hybrid prostheses. A comparison of clinical and radiographic results at two to four years. J Bone Joint Surg Am 1991; 73: 257-270
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 257-270
    • Wixson, R.L.1    Stulberg, S.D.2    Mehlhoff, M.3
  • 26
    • 0024268631 scopus 로고
    • Heterotopic ossification after direct lateral approach and transtrochanteric approach to the hip
    • Testa NN, Mazur KU, Heterotopic ossification after direct lateral approach and transtrochanteric approach to the hip. Orthop Rev 1988; 17: 965-971
    • (1988) Orthop Rev , vol.17 , pp. 965-971
    • Testa, N.N.1    Mazur, K.U.2
  • 27
    • 0034828397 scopus 로고    scopus 로고
    • Risk factors for heterotopic ossification in total hip arthroplasty
    • Eggli S, Woo A. Risk factors for heterotopic ossification in total hip arthroplasty. Arch Orthop Trauma Surg 2001; 121: 531-535
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 531-535
    • Eggli, S.1    Woo, A.2
  • 28
    • 0033848276 scopus 로고    scopus 로고
    • The superolateral approach for aspiration of total hip arthroplasties
    • McCurdy WE, Moore TE, Walker CW. The superolateral approach for aspiration of total hip arthroplasties. Australas Radiol 2000; 44: 349-350
    • (2000) Australas Radiol , vol.44 , pp. 349-350
    • McCurdy, W.E.1    Moore, T.E.2    Walker, C.W.3
  • 29
    • 0028605179 scopus 로고
    • Heterotopic ossification following uncemented total hip arthroplasty. Effect of the operative approach
    • Bischoff R, Dunlap J, Carpenter L, DeMouy E, Barrack R. Heterotopic ossification following uncemented total hip arthroplasty. Effect of the operative approach. J Arthroplasty 1994; 9: 641-644
    • (1994) J Arthroplasty , vol.9 , pp. 641-644
    • Bischoff, R.1    Dunlap, J.2    Carpenter, L.3    DeMouy, E.4    Barrack, R.5
  • 30
    • 0025980718 scopus 로고
    • Periarticular heterotopic ossification after total hip arthroplasty. Risk factors and consequences
    • Ahrengart L. Periarticular heterotopic ossification after total hip arthroplasty. Risk factors and consequences. Clin Orthop 1991: 49-58
    • (1991) Clin Orthop , pp. 49-58
    • Ahrengart, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.