메뉴 건너뛰기




Volumn 137, Issue 2, 1999, Pages 108-113

Proximally porous coated total hip-replacement: 6-Year results;Proximale verankerung von huft-endoprothesen mit poroser oberflache: 6- Jahres-ergebnisse

Author keywords

Cementless; Porous coated; Thigh pain; Total hip replacement

Indexed keywords

ADULT; AGED; ARTICLE; FEMALE; FOLLOW UP; HIP PROSTHESIS; HIP RADIOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; MALE; POROSITY; PROSTHESIS LOOSENING; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME; BONE REGENERATION; EQUIPMENT; MIDDLE AGED; PHYSIOLOGY; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PAIN; PROSTHESIS; RADIOGRAPHY; REOPERATION; WEIGHT BEARING;

EID: 0033088786     PISSN: 00443220     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1039343     Document Type: Article
Times cited : (6)

References (27)
  • 4
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone
    • 4 Bobyn, J. D., R. M. Pilliar, H. U. Cameron, G. C. Weatherly: The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin. Orthop. 150 (1980) 263-270
    • (1980) Clin. Orthop. , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 5
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement: Incidence and a method of classification
    • 5 Brooker, A. F., J. W. Bowerman, R. A. Robinson, L. H. Riley Jr.: Ectopic ossification following total hip replacement: incidence and a method of classification. J. Bone Joint Surg. 55-A (1973) 1629-1632
    • (1973) J. Bone Joint Surg. , vol.55 A , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley L.H., Jr.4
  • 6
    • 0023675987 scopus 로고
    • Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases
    • 6 Davey, J. R., W. H. Harris: Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases. Clin. Orthop. 231 (1988) 97-102
    • (1988) Clin. Orthop. , vol.231 , pp. 97-102
    • Davey, J.R.1    Harris, W.H.2
  • 7
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • 7 DeLee, J. G., J. Charnley: Radiological demarcation of cemented sockets in total hip replacement. Clin. Orthop. 121 (1976) 20-32
    • (1976) Clin. Orthop. , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 9
    • 0023240947 scopus 로고
    • Porous-coated hip replacement: The factors governing bone ingrowth, stress shielding, and clinical results
    • 9 Engh, C. A., J. B. Bobyn, A. H. Glassman: Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J. Bone Joint Surg. 69-B (1987) 45-55
    • (1987) J. Bone Joint Surg. , vol.69 B , pp. 45-55
    • Engh, C.A.1    Bobyn, J.B.2    Glassman, A.H.3
  • 11
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem-type femoral components. A radiographic analysis of loosening
    • 11 Gruen, T. A., G. M. McNeice, H. M. Amstutz: Modes of failure of cemented stem-type femoral components. A radiographic analysis of loosening. Clin. Orthop. 141 (1979) 17-27
    • (1979) Clin. Orthop. , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.M.3
  • 12
    • 0025173895 scopus 로고
    • A comparison of three varieties of noncemented porous-coated hip replacement
    • 12 Haddad, R. J., S. D. Cook, M. R. Brinker: A comparison of three varieties of noncemented porous-coated hip replacement. J. Bone Joint Surg. 72-B (1990) 2-8
    • (1990) J. Bone Joint Surg. , vol.72 B , pp. 2-8
    • Haddad, R.J.1    Cook, S.D.2    Brinker, M.R.3
  • 13
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty
    • 13 Harris, W. H.: Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by Mold arthroplasty. J. Bone Joint Surg. 51-A (1969) 737-753
    • (1969) J. Bone Joint Surg. , vol.51 A , pp. 737-753
    • Harris, W.H.1
  • 15
    • 0013632946 scopus 로고
    • Zur frage postoperativer schmerzen bei zementfreien hüftendoprothesen
    • 15 Heimke, G., D. Stock: Zur Frage postoperativer Schmerzen bei zementfreien Hüftendoprothesen. Z. Orthop. 124 (1986) 634-645
    • (1986) Z. Orthop. , vol.124 , pp. 634-645
    • Heimke, G.1    Stock, D.2
  • 16
    • 0022386119 scopus 로고
    • Die anatomisch angepaßte endoprothese des proximalen femurendes
    • 16 Henßge, E. J., H. Grundei, R. Etspüler, W. Köller, K. Fink: Die anatomisch angepaßte Endoprothese des proximalen Femurendes. Z. Orthop. 123 (1985) 821-828
    • (1985) Z. Orthop. , vol.123 , pp. 821-828
    • Henßge, E.J.1    Grundei, H.2    Etspüler, R.3    Köller, W.4    Fink, K.5
  • 17
    • 0027724018 scopus 로고
    • Zementfreie hüftendoprothetik: PCA-schaftprothesen, 5-7 jahresresultate
    • 17 Hösli, P.: Zementfreie Hüftendoprothetik: PCA-Schaftprothesen, 5-7 Jahresresultate. Z. Orthop. 131 (1993) 518-523
    • (1993) Z. Orthop. , vol.131 , pp. 518-523
    • Hösli, P.1
  • 18
    • 0022371841 scopus 로고
    • Gegossene spongiösmetallische implantate im tierversuch
    • 18 Krüger, M., E. J. Henssge, D. Sellin: Gegossene spongiösmetallische Implantate im Tierversuch. Z. Orthop. 123 (1985) 962-965
    • (1985) Z. Orthop. , vol.123 , pp. 962-965
    • Krüger, M.1    Henssge, E.J.2    Sellin, D.3
  • 19
    • 0028892402 scopus 로고
    • Accuracy of migration analysis in total hip arthroplasty: Digitized and conventional radiography, compared to radiostereometry in 51 patients
    • 19 Malchau, H., J. Kärrholm, Y. X. Wang, P. Herberts: Accuracy of migration analysis in total hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop. Scand. 66 (1995) 418-424
    • (1995) Acta Orthop. Scand. , vol.66 , pp. 418-424
    • Malchau, H.1    Kärrholm, J.2    Wang, Y.X.3    Herberts, P.4
  • 20
    • 0029850587 scopus 로고    scopus 로고
    • Long-term clinical and radiological results of the Lord total hip prosthesis. A prospective study
    • 20 Malchau, H., P. Herberts, Y. X. Wang, J. Kürrholm, B. Romanus: Long-term clinical and radiological results of the Lord total hip prosthesis. A prospective study. J. Bone Joint Surg. 78-B (1996) 884-891
    • (1996) J. Bone Joint Surg. , vol.78 B , pp. 884-891
    • Malchau, H.1    Herberts, P.2    Wang, Y.X.3    Kürrholm, J.4    Romanus, B.5
  • 22
    • 0028926599 scopus 로고
    • Bedeutung röntgenologischer und szintigraphischer untersuchungen bei patienten mit und ohne oberschenkelschmerz nach zementfreier PCA-hüftendoprothese
    • 22 Pohlemann, T., M. Steinmetz, C. Ehrenheim, H. Hundeshagen, H. Tscherne: Bedeutung röntgenologischer und szintigraphischer Untersuchungen bei Patienten mit und ohne Oberschenkelschmerz nach zementfreier PCA-Hüftendoprothese. Z. Orthop. 133 (1995) 25-33
    • (1995) Z. Orthop. , vol.133 , pp. 25-33
    • Pohlemann, T.1    Steinmetz, M.2    Ehrenheim, C.3    Hundeshagen, H.4    Tscherne, H.5
  • 23
    • 0027744406 scopus 로고
    • Biologische fixation und klinische ergebnisse der zementfreien lübecker totalendoprothese aus spongiosametall
    • 23 Sprick, O., P. Dufek: Biologische Fixation und klinische Ergebnisse der zementfreien Lübecker Totalendoprothese aus Spongiosametall. Z. Orthop. 131 (1993) 524-531
    • (1993) Z. Orthop. , vol.131 , pp. 524-531
    • Sprick, O.1    Dufek, P.2
  • 24
    • 0022830205 scopus 로고
    • A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model
    • 24 Turner T. M., D. R. Sumner, R. M. Urban, D. P. Rivero, J. O. Galante: A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model. J. Bone Joint Surg. 68-A (1986) 1396-1409
    • (1986) J. Bone Joint Surg. , vol.68 A , pp. 1396-1409
    • Turner, T.M.1    Sumner, D.R.2    Urban, R.M.3    Rivero, D.P.4    Galante, J.O.5
  • 25
    • 0031464956 scopus 로고    scopus 로고
    • Ursachen, diagnostik und therapic der aseptischen hüftendoprothesenlockerung - Eine standortbestimmung
    • 25 Wirtz, C. D., F. U. Niethard: Ursachen, Diagnostik und Therapic der aseptischen Hüftendoprothesenlockerung - eine Standortbestimmung. Z. Orthop. 135 (1997) 270-280
    • (1997) Z. Orthop. , vol.135 , pp. 270-280
    • Wirtz, C.D.1    Niethard, F.U.2
  • 26
    • 0024259874 scopus 로고
    • Klinische ergebnisse zementfreier hüftendoprothesen Typ PM
    • 26 Wolf, Th., A. Reichelt, P. Schlepckow: Klinische Ergebnisse zementfreier Hüftendoprothesen Typ PM. Z. Orthop. 126 (1988) 637-642
    • (1988) Z. Orthop. , vol.126 , pp. 637-642
    • Wolf, Th.1    Reichelt, A.2    Schlepckow, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.