메뉴 건너뛰기




Volumn 26, Issue 9-10, 2003, Pages 1345-1354

A new small coil-volume CCC instrument for direct interfacing with MS

Author keywords

J type coil planet centrifuge; Mass spectrometry coupling; Small volume CCC machine

Indexed keywords

GEARS; MASS SPECTROMETERS; SEPARATION;

EID: 0037561225     PISSN: 10826076     EISSN: None     Source Type: Journal    
DOI: 10.1081/JLC-120021254     Document Type: Conference Paper
Times cited : (27)

References (11)
  • 1
    • 0003162039 scopus 로고
    • Principles and instrumentation of countercurrent chromatography
    • Mandava, N.B., Ito, Y., Eds.; Marcel Dekker Inc: New York
    • Ito, Y. Principles and instrumentation of countercurrent chromatography. In Countercurrent Chromatography - Theory & Practice; Mandava, N.B., Ito, Y., Eds.; Marcel Dekker Inc: New York, 1988; 79-442.
    • (1988) Countercurrent Chromatography - Theory & Practice , pp. 79-442
    • Ito, Y.1
  • 2
    • 0025933428 scopus 로고
    • Efficiency and resolution in countercurrent chromatography
    • Bousquet, O.; Foucault, A.P.; Le Goffic, F. Efficiency and resolution in countercurrent chromatography. J. Liq. Chromatogr. 1991, 14 (18), 3343-3363.
    • (1991) J. Liq. Chromatogr. , vol.14 , Issue.18 , pp. 3343-3363
    • Bousquet, O.1    Foucault, A.P.2    Le Goffic, F.3
  • 3
    • 0038575487 scopus 로고    scopus 로고
    • Resolution in countercurrent chromatography: The effect of operating conditions and phase system properties on scale up
    • Sutherland, I.A.; Hawes, D.; Van Den Heuvel, R.; Janaway, L.; Tinnion, E. Resolution in countercurrent chromatography: the effect of operating conditions and phase system properties on scale up. J. Liq. Chromatogr. & Rel. Technol. 2003, 26 (9&10), 1475-1492.
    • (2003) J. Liq. Chromatogr. & Rel. Technol. , vol.26 , Issue.9-10 , pp. 1475-1492
    • Sutherland, I.A.1    Hawes, D.2    Van Den Heuvel, R.3    Janaway, L.4    Tinnion, E.5
  • 4
    • 0023666150 scopus 로고
    • Analytical high speed counter-current chromatography with a coil planet centrifuge
    • Ito, Y.; Lee, Y.W. Analytical high speed counter-current chromatography with a coil planet centrifuge. J. Chromatogr. 1987, 391, 290-295.
    • (1987) J. Chromatogr. , vol.391 , pp. 290-295
    • Ito, Y.1    Lee, Y.W.2
  • 5
    • 0023834270 scopus 로고
    • Analytical high speed countercurrent chromatography
    • Lee, Y.W.; Ito, Y.; Fang, Q.C.; Cook, C.E. Analytical high speed countercurrent chromatography. J. Liq. Chromatogr. 1988, 11 (1), 75-89.
    • (1988) J. Liq. Chromatogr. , vol.11 , Issue.1 , pp. 75-89
    • Lee, Y.W.1    Ito, Y.2    Fang, Q.C.3    Cook, C.E.4
  • 6
    • 0025241339 scopus 로고
    • Evaluation of analytical countercurrent chromatographs: High speed countercurrent chromatograph-4000 vs. analytical toroidal coil centrifuge
    • Oka, H.; Ikai, Y.; Kawamura, N.; Yamada, M.; Harada, K.-I.; Suzuki, M.; Chou, F.E.; Lee, Y.-W.; Ito, Y. Evaluation of analytical countercurrent chromatographs: high speed countercurrent chromatograph-4000 vs. analytical toroidal coil centrifuge. J. Liq. Chromatogr. 1990, 13 (12), 2309-2328.
    • (1990) J. Liq. Chromatogr. , vol.13 , Issue.12 , pp. 2309-2328
    • Oka, H.1    Ikai, Y.2    Kawamura, N.3    Yamada, M.4    Harada, K.-I.5    Suzuki, M.6    Chou, F.E.7    Lee, Y.-W.8    Ito, Y.9
  • 8
    • 0037556922 scopus 로고    scopus 로고
    • UK Patents, GB 0207959.8, GB 0207961.4, GB 0207963.0, GB 0207962.2, April 5, 2002
    • UK Patents, GB 0207959.8, GB 0207961.4, GB 0207963.0, GB 0207962.2, April 5, 2002.
  • 9
    • 0026426022 scopus 로고
    • Direct interfacing of high speed countercurrent chromatography to frit electron ionization, chemical ionization, and fast atom bombardment mass spectroscopy
    • Oka, H.; Ikai, Y.; Kawamura, N.; Hayakawa, J.; Harada, K.-I.; Murata, H.; Suzuki, M.; Ito, Y. Direct interfacing of high speed countercurrent chromatography to frit electron ionization, chemical ionization, and fast atom bombardment mass spectroscopy. Anal. Chem. 1991, 63, 2861-2865.
    • (1991) Anal. Chem. , vol.63 , pp. 2861-2865
    • Oka, H.1    Ikai, Y.2    Kawamura, N.3    Hayakawa, J.4    Harada, K.-I.5    Murata, H.6    Suzuki, M.7    Ito, Y.8
  • 10
    • 0034912888 scopus 로고    scopus 로고
    • Separation and characterisation of five polar herbicides using countercurrent chromatography with detection by negative ion electrospray ionisation mass spectroscopy
    • Kidwell, H.; Jones, J.J.; Games, D.E. Separation and characterisation of five polar herbicides using countercurrent chromatography with detection by negative ion electrospray ionisation mass spectroscopy. Rapid Commun. Mass Spectrom. 2001, 15, 1181-1186.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 1181-1186
    • Kidwell, H.1    Jones, J.J.2    Games, D.E.3
  • 11
    • 0037899283 scopus 로고    scopus 로고
    • Modelling countercurrent chromatography using an eluting countercurrent distribution model
    • Sutherland, I.A.; de Folter, J.; Wood, P. Modelling countercurrent chromatography using an eluting countercurrent distribution model. J. Liq. Chromatogr. & Rel. Technol. 2003, 26 (9&10), 1449-1474.
    • (2003) J. Liq. Chromatogr. & Rel. Technol. , vol.26 , Issue.9-10 , pp. 1449-1474
    • Sutherland, I.A.1    De Folter, J.2    Wood, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.