메뉴 건너뛰기




Volumn 50, Issue 4, 2003, Pages 402-407

Characterization of trabecular bone using the backscattered spectral centroid shift

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC WAVE BACKSCATTERING; ACOUSTIC WAVE TRANSMISSION; ATTENUATION; BONE; DISEASES; ULTRASONIC TRANSDUCERS;

EID: 0037534355     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2003.1197963     Document Type: Article
Times cited : (43)

References (60)
  • 1
    • 0030737927 scopus 로고    scopus 로고
    • Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status
    • C. C. Glüer, "Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status," J. Bone Miner. Res., vol. 12, pp. 1280-1288, 1997.
    • (1997) J. Bone Miner. Res. , vol.12 , pp. 1280-1288
    • Glüer, C.C.1
  • 2
    • 0021408517 scopus 로고
    • The measurement of broadband ultrasonic attenuation in cancellous bone
    • C. M. Langton, S. B. Palmer, and R. W. Porter, "The measurement of broadband ultrasonic attenuation in cancellous bone," Eng. Med., vol. 13, pp. 89-91, 1984.
    • (1984) Eng. Med. , vol.13 , pp. 89-91
    • Langton, C.M.1    Palmer, S.B.2    Porter, R.W.3
  • 3
    • 0024760698 scopus 로고
    • Comparison of speed of sound and ultrasound attenuation in the os calcis to bone density of the radius, femur and lumbar spine
    • P. Rossman, J. Zagzebski, C. Mesina, J. Sorenson, and R. Mazess, "Comparison of speed of sound and ultrasound attenuation in the os calcis to bone density of the radius, femur and lumbar spine," Clin. Phys. Physiol. Meas., vol. 10, pp. 353-360, 1989.
    • (1989) Clin. Phys. Physiol. Meas. , vol.10 , pp. 353-360
    • Rossman, P.1    Zagzebski, J.2    Mesina, C.3    Sorenson, J.4    Mazess, R.5
  • 4
    • 0025940712 scopus 로고
    • Dependence of the velocity and attenuation of ultrasound in bone on the mineral content
    • M. B. Tavakoli and J. A. Evans, "Dependence of the velocity and attenuation of ultrasound in bone on the mineral content," Phys. Med. Biol., vol. 36, pp. 1529-1537, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1529-1537
    • Tavakoli, M.B.1    Evans, J.A.2
  • 6
    • 0030199935 scopus 로고    scopus 로고
    • Orthogonal relationships between ultrasonic velocity and material properties of bovine cancellous bone
    • C. F. Njeh, R. Hodgskinson, J. D. Currey, and C. M. Langton, "Orthogonal relationships between ultrasonic velocity and material properties of bovine cancellous bone," Med. Eng. Phys., vol. 18, pp. 373-381, 1996.
    • (1996) Med. Eng. Phys. , vol.18 , pp. 373-381
    • Njeh, C.F.1    Hodgskinson, R.2    Currey, J.D.3    Langton, C.M.4
  • 7
    • 0030176206 scopus 로고    scopus 로고
    • Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation
    • C. M. Langton, C. F. Njeh, R. Hodgskinson, and J. D. Carrey, "Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation," Bone, vol. 18, pp. 495-503, 1996.
    • (1996) Bone , vol.18 , pp. 495-503
    • Langton, C.M.1    Njeh, C.F.2    Hodgskinson, R.3    Carrey, J.D.4
  • 8
    • 0030973360 scopus 로고    scopus 로고
    • Quantitative ultrasound of the calcaneus reflects the mechanical properties of calcaneal trabecular bone
    • M. L. Bouxsein and S. E. Radloff, "Quantitative ultrasound of the calcaneus reflects the mechanical properties of calcaneal trabecular bone," J. Bone Miner. Res., vol. 12, pp. 839-846, 1997.
    • (1997) J. Bone Miner. Res. , vol.12 , pp. 839-846
    • Bouxsein, M.L.1    Radloff, S.E.2
  • 9
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography
    • P. Laugier, P. Droin, A. M. Laval-Jeantet, and G. Berger, "In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography," Bone, vol. 20, pp. 157-165, 1997.
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Laval-Jeantet, A.M.3    Berger, G.4
  • 12
    • 0032892896 scopus 로고    scopus 로고
    • Ultrasound velocity and attenuation in cancellous bone samples from lumbar vertebra and calcaneus
    • H. Trebacz and A. Nataliu, "Ultrasound velocity and attenuation in cancellous bone samples from lumbar vertebra and calcaneus," Osteo. Int., vol. 9, pp. 99-105, 1999.
    • (1999) Osteo. Int. , vol.9 , pp. 99-105
    • Trebacz, H.1    Nataliu, A.2
  • 13
    • 0030741752 scopus 로고    scopus 로고
    • Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    • C. Chappard, P. Laugier, B. Fornier, C. Roux, and G. Berger, "Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA," Osteo. Int., vol. 7, pp. 316-322, 1997.
    • (1997) Osteo. Int. , vol.7 , pp. 316-322
    • Chappard, C.1    Laugier, P.2    Fournier, B.3    Roux, C.4    Berger, G.5
  • 16
    • 0030934837 scopus 로고    scopus 로고
    • Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women
    • D. C. Bauer, C. C. Gluer, J. A. Cauley, T. M. Vogt, K. E. Ensrud, H. K. Genant, and D. M. Black, "Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women," Arch. Intern. Med., vol. 157, pp. 629-634, 1997.
    • (1997) Arch. Intern. Med. , vol.157 , pp. 629-634
    • Bauer, D.C.1    Gluer, C.C.2    Cauley, J.A.3    Vogt, T.M.4    Ensrud, K.E.5    Genant, H.K.6    Black, D.M.7
  • 17
    • 0028911460 scopus 로고
    • Ultrasound discriminates patients with hip fracture equally well as dual energy x-ray absorptiometry and independently of bone mineral density
    • M. Schott, S. Weill-Engerer, D. Hans, F. Duboeuf, P. D. Delmas, and P. J. Meunier, "Ultrasound discriminates patients with hip fracture equally well as dual energy X-ray absorptiometry and independently of bone mineral density," J. Bone Miner. Res., vol. 10, pp. 243-249, 1995.
    • (1995) J. Bone Miner. Res. , vol.10 , pp. 243-249
    • Schott, M.1    Weill-Engerer, S.2    Hans, D.3    Duboeuf, F.4    Delmas, P.D.5    Meunier, P.J.6
  • 18
    • 0028939835 scopus 로고
    • Calcaneal ultrasonic measurements discriminate hip fracture independently of bone mass
    • H. Turner, M. Peacock, L. Timmerman, J. M. Neal, and C. C. Johnston, Jr, "Calcaneal ultrasonic measurements discriminate hip fracture independently of bone mass," Osteo. Int., vol. 5, pp. 130-135, 1995.
    • (1995) Osteo. Int. , vol.5 , pp. 130-135
    • Turner, H.1    Peacock, M.2    Timmerman, L.3    Neal, J.M.4    Johnston C.C., Jr.5
  • 20
    • 0031668816 scopus 로고    scopus 로고
    • Quantitative heel ultrasound in 3180 women between 45 and 75 years of age: Compliance, normal ranges and relationship to fracture history
    • P. Thompson, J. Taylor, A. Fisher, and R. Oliver, "Quantitative heel ultrasound in 3180 women between 45 and 75 years of age: Compliance, normal ranges and relationship to fracture history," Osteo. Int., vol. 8, pp. 211-214, 1998.
    • (1998) Osteo. Int. , vol.8 , pp. 211-214
    • Thompson, P.1    Taylor, J.2    Fisher, A.3    Oliver, R.4
  • 21
    • 0000259263 scopus 로고
    • In vivo liver and splenic tissue characterization by scattering
    • K. K. Shung, Ed. Boca Raton, FL: CRC Press
    • B. S. Garra, "In vivo liver and splenic tissue characterization by scattering," in Ultrasonic Scattering in Biological Tissues. K. K. Shung, Ed. Boca Raton, FL: CRC Press, 1993, pp. 347-392.
    • (1993) Ultrasonic Scattering in Biological Tissues , pp. 347-392
    • Garra, B.S.1
  • 22
    • 0019451760 scopus 로고
    • Analysis of the error in measurement of ultrasound speed in tissue due to waveform deformation by frequency-dependent attenuation
    • M. Ragozzino, "Analysis of the error in measurement of ultrasound speed in tissue due to waveform deformation by frequency-dependent attenuation," Ultrasonics, vol. 19, pp. 135-138, 1981.
    • (1981) Ultrasonics , vol.19 , pp. 135-138
    • Ragozzino, M.1
  • 23
    • 0020960166 scopus 로고
    • A closed form method for the measurement of attenuation in nonlinearly dispersive media
    • P. A. Narayana and J. Ophir, "A closed form method for the measurement of attenuation in nonlinearly dispersive media," Ultrason. Imag., vol. 5, pp. 17-21, 1983.
    • (1983) Ultrason. Imag. , vol.5 , pp. 17-21
    • Narayana, P.A.1    Ophir, J.2
  • 24
    • 0019589811 scopus 로고
    • Ultrasonic attenuation and propagation speed in normal human brain
    • F. W. Kremkau, R. W. Barnes, and C. P. McGraw, "Ultrasonic attenuation and propagation speed in normal human brain," J. Acoust. Soc. Amer., vol. 70, pp. 29-38, 1981.
    • (1981) J. Acoust. Soc. Amer. , vol.70 , pp. 29-38
    • Kremkau, F.W.1    Barnes, R.W.2    McGraw, C.P.3
  • 25
    • 0020972537 scopus 로고
    • Measurement of ultrasonic attenuation within regions selected from B-scan images
    • K. J. Parker and R. C. Waag, "Measurement of ultrasonic attenuation within regions selected from B-scan images," IEEE Trans. Biomed. Eng., vol. BME-30, pp. 431-437, 1983.
    • (1983) IEEE Trans. Biomed. Eng. , vol.BME-30 , pp. 431-437
    • Parker, K.J.1    Waag, R.C.2
  • 26
    • 0005031416 scopus 로고
    • In vivo measurement of frequency dependent attenuation in normal liver, pacreas, and spleen
    • J. P. Jones and M. Behrens, "In vivo measurement of frequency dependent attenuation in normal liver, pacreas, and spleen," Ultrason. Imag., vol. 3, p. 205, 1981.
    • (1981) Ultrason. Imag. , vol.3 , pp. 205
    • Jones, J.P.1    Behrens, M.2
  • 27
    • 0021702197 scopus 로고
    • Attenuation of ultrasound: Magnitude and frequency dependence for tissue characterization
    • K. J. Parker, R. M. Lerner, and R. C. Waag, "Attenuation of ultrasound: Magnitude and frequency dependence for tissue characterization," Radiology, vol. 153, pp. 785-788, 1984.
    • (1984) Radiology , vol.153 , pp. 785-788
    • Parker, K.J.1    Lerner, R.M.2    Waag, R.C.3
  • 28
    • 0023430894 scopus 로고
    • Frequency-dependent ultrasonic differentiation of normal and diffusely disease liver
    • T. Lin, J. Ophir, and G. Potter, "Frequency-dependent ultrasonic differentiation of normal and diffusely disease liver," J. Acoust. Soc. Amer., vol. 82, pp. 1131-1138, 1987.
    • (1987) J. Acoust. Soc. Amer. , vol.82 , pp. 1131-1138
    • Lin, T.1    Ophir, J.2    Potter, G.3
  • 29
    • 0023861054 scopus 로고
    • In vivo measurements of ultrasound attenuation in normal or diseased liver
    • K. J. Parker, M. S. Asztely, R. M. Lerner, E. A. Schenk, and R. C. Waag, "In vivo measurements of ultrasound attenuation in normal or diseased liver," Ultrasound Med. Biol., vol. 14, pp. 127-136, 1988.
    • (1988) Ultrasound Med. Biol. , vol.14 , pp. 127-136
    • Parker, K.J.1    Asztely, M.S.2    Lerner, R.M.3    Schenk, E.A.4    Waag, R.C.5
  • 30
    • 0018568468 scopus 로고
    • Transmission of ultrasound beams through human tissue-focussing and attenuation studies
    • F. S. Foster and J. W. Hunt, "Transmission of ultrasound beams through human tissue-focussing and attenuation studies," Ultrasound Med. Biol., vol. 5, pp. 257-268, 1979.
    • (1979) Ultrasound Med. Biol. , vol.5 , pp. 257-268
    • Foster, F.S.1    Hunt, J.W.2
  • 31
    • 0020945427 scopus 로고    scopus 로고
    • Frequency dependent ultrasonic attenuation coefficient assessment in fresh tissue
    • L. A. Segal and W. D. O'Brien, "Frequency dependent ultrasonic attenuation coefficient assessment in fresh tissue," in Proc. IEEE Ultrason. Symp., 1983, pp. 797-799.
    • Proc. IEEE Ultrason. Symp., 1983 , pp. 797-799
    • Segal, L.A.1    O'Brien, W.D.2
  • 32
    • 0021456372 scopus 로고
    • The attenuation of ultrasound in biological fluids
    • P. A. Narayana, J. Ophir, and N. F. Maklad, "The attenuation of ultrasound in biological fluids," J. Acoust. Soc. Amer., vol. 76, pp. 1-4, 1984.
    • (1984) J. Acoust. Soc. Amer. , vol.76 , pp. 1-4
    • Narayana, P.A.1    Ophir, J.2    Maklad, N.F.3
  • 34
    • 0030499468 scopus 로고    scopus 로고
    • On the measurement of the velocity of ultrasound in the os calcis using short pulses
    • R. Strelitzki and J. A. Evans, "On the measurement of the velocity of ultrasound in the os calcis using short pulses," Eur. J. Ultrasound, vol. 4, pp. 205-213, 1996.
    • (1996) Eur. J. Ultrasound , vol.4 , pp. 205-213
    • Strelitzki, R.1    Evans, J.A.2
  • 35
    • 0029907932 scopus 로고    scopus 로고
    • Comparison of time-domain and frequency domain approaches to ultrasonic velocity measurements in trabecular bone
    • P. H. F. Nicholson, G. Lowet, C. M. Langton, J. Dequeker, and G. van der Perre, "Comparison of time-domain and frequency domain approaches to ultrasonic velocity measurements in trabecular bone," Phys. Med. Biol., vol. 41, pp. 2421-2435, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2421-2435
    • Nicholson, P.H.F.1    Lowet, G.2    Langton, C.M.3    Dequeker, J.4    Van Der Perre, G.5
  • 36
    • 0033896977 scopus 로고    scopus 로고
    • The effects of frequency-dependent attenuation and dispersion on sound speed measurements: Applications in human trabecular bone
    • K. A. Wear, "The effects of frequency-dependent attenuation and dispersion on sound speed measurements: Applications in human trabecular bone," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 47, pp. 265-273, 2000.
    • (2000) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.47 , pp. 265-273
    • Wear, K.A.1
  • 37
    • 0034036395 scopus 로고    scopus 로고
    • Measurements of phase velocity and group velocity in human calcaneus
    • K. A. Wear, "Measurements of phase velocity and group velocity in human calcaneus," Ultrasound Med. Biol., vol. 26, pp. 641-646, 2000.
    • (2000) Ultrasound Med. Biol. , vol.26 , pp. 641-646
    • Wear, K.A.1
  • 38
    • 0033813008 scopus 로고    scopus 로고
    • In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz
    • S. Chaffai, F. Padilla, G. Berger, and P. Laugier, "In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz," J. Acoust. Soc. Amer., vol. 108, pp. 1281-1289, 2000.
    • (2000) J. Acoust. Soc. Amer. , vol.108 , pp. 1281-1289
    • Chaffai, S.1    Padilla, F.2    Berger, G.3    Laugier, P.4
  • 39
    • 0035263392 scopus 로고    scopus 로고
    • Ultrasonic attenuation in human calcaneus from 0.2 to 1.7 MHz
    • K. A. Wear, "Ultrasonic attenuation in human calcaneus from 0.2 to 1.7 MHz," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 48, pp. 602-608, 2001.
    • (2001) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.48 , pp. 602-608
    • Wear, K.A.1
  • 40
    • 0030904757 scopus 로고    scopus 로고
    • The effect of cortical endplates on ultrasound velocity through the calcaneus: An in vitro study
    • F. Njeh and C. M. Langton, "The effect of cortical endplates on ultrasound velocity through the calcaneus: An in vitro study," Br. J. Radiol., vol. 70, pp. 504-510, 1997.
    • (1997) Br. J. Radiol. , vol.70 , pp. 504-510
    • Njeh, F.1    Langton, C.M.2
  • 42
    • 0002470583 scopus 로고    scopus 로고
    • Factors influencing QUS parameters of the calcaneum: Suggestions for an improved measurement procedure
    • R. Barkmann and C. C. Glüer, "Factors influencing QUS parameters of the calcaneum: Suggestions for an improved measurement procedure," J. Clin. Densitometry, vol. 1, pp. 93-94, 1998.
    • (1998) J. Clin. Densitometry , vol.1 , pp. 93-94
    • Barkmann, R.1    Glüer, C.C.2
  • 43
    • 0032934185 scopus 로고    scopus 로고
    • Ultrasound measurement on the calcaneus: Influence of immersion time and rotation of the foot
    • C. Chappard, G. Berger, C. Roux, and P. Laugier, "Ultrasound measurement on the calcaneus: Influence of immersion time and rotation of the foot," Osteo. Int., vol. 9, pp. 318-326, 1999.
    • (1999) Osteo. Int. , vol.9 , pp. 318-326
    • Chappard, C.1    Berger, G.2    Roux, C.3    Laugier, P.4
  • 44
    • 0034037757 scopus 로고    scopus 로고
    • Temperature dependence of ultrasonic attenuation in human calcaneus
    • K. A. Wear, "Temperature dependence of ultrasonic attenuation in human calcaneus," Ultrasound Med. Biol., vol. 26, pp. 469-472, 2000.
    • (2000) Ultrasound Med. Biol. , vol.26 , pp. 469-472
    • Wear, K.A.1
  • 45
    • 0018516290 scopus 로고
    • Estimating the acoustic attenuation coefficient slope for liver from reflected ultrasound signals
    • R. Kuc and M. Schwartz, "Estimating the acoustic attenuation coefficient slope for liver from reflected ultrasound signals," IEEE Trans. Sonics Ultrason., vol. SU-26, pp. 353-362, 1979.
    • (1979) IEEE Trans. Sonics Ultrason. , vol.SU-26 , pp. 353-362
    • Kuc, R.1    Schwartz, M.2
  • 46
    • 0027605877 scopus 로고
    • Diffraction correction methods for insertion ultrasound attenuation estimation
    • W. Xu and J. J. Kaufman, "Diffraction correction methods for insertion ultrasound attenuation estimation," IEEE Trans. Biomed. Eng., vol. 40, pp. 563-570, 1993.
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 563-570
    • Xu, W.1    Kaufman, J.J.2
  • 50
    • 0032761734 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment
    • K. A. Wear, "Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment," J. Acoust. Soc. Amer., vol. 106, pp. 3659-3664, 1999.
    • (1999) J. Acoust. Soc. Amer. , vol.106 , pp. 3659-3664
    • Wear, K.A.1
  • 51
    • 0033773586 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscattering in cancellous bone: Autocorrelation model and experimental results
    • S. Chaffai, V. Roberjot, F. Peyrin, G. Berger, and P. Laugier, "Frequency dependence of ultrasonic backscattering in cancellous bone: Autocorrelation model and experimental results," J. Acoust. Soc. Amer., vol. 108, pp. 2403-2411, 2000.
    • (2000) J. Acoust. Soc. Amer. , vol.108 , pp. 2403-2411
    • Chaffai, S.1    Roberjot, V.2    Peyrin, F.3    Berger, G.4    Laugier, P.5
  • 52
    • 0019527603 scopus 로고
    • Quantitative broadband ultrasonic backscatter: An approach to nondestructive evaluation in acoustically inhomogeneous materials
    • M. O'Donnell and J. G. Miller, "Quantitative broadband ultrasonic backscatter: An approach to nondestructive evaluation in acoustically inhomogeneous materials," J. Appl. Phys., vol. 52, pp. 1056-1065, 1981.
    • (1981) J. Appl. Phys. , pp. 1056-1065
    • O'Donnell, M.1    Miller, J.G.2
  • 53
    • 0035209136 scopus 로고    scopus 로고
    • Fundamental precision limitations for measurements of frequency dependence of backscatter: Applications in tissue-mimicking phantoms and trabecular bone
    • K. A. Wear, "Fundamental precision limitations for measurements of frequency dependence of backscatter: Applications in tissue-mimicking phantoms and trabecular bone," J. Acoust. Soc. Amer., vol. 110, pp. 3275-3282, 2001.
    • (2001) J. Acoust. Soc. Amer. , vol.110 , pp. 3275-3282
    • Wear, K.A.1
  • 54
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • D. Ulrich, B. van Rietbergen, A. Laib, and P. Ruegsegger, "The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone," Bone, vol. 25, pp. 55-60, 1999.
    • (1999) Bone , vol.25 , pp. 55-60
    • Ulrich, D.1    Van Rietbergen, B.2    Laib, A.3    Ruegsegger, P.4
  • 55
    • 0034933002 scopus 로고    scopus 로고
    • Relationships among calcaneal backscatter, hip bone mineral density, and age in normal adult women
    • July
    • K. A. Wear and D. W. Armstrong, "Relationships among calcaneal backscatter, hip bone mineral density, and age in normal adult women," J. Acoust. Soc. Amer., vol. 110, no. 1, pp. 573-578, July 2001.
    • (2001) J. Acoust. Soc. Amer. , vol.110 , Issue.1 , pp. 573-578
    • Wear, K.A.1    Armstrong, D.W.2
  • 56
    • 0032101740 scopus 로고    scopus 로고
    • Assessment of bone density using ultrasonic backscatter
    • K. A. Wear and B. S. Garra, "Assessment of bone density using ultrasonic backscatter," Ultrasound Med. Biol., vol. 24, pp. 689-695, 1998.
    • (1998) Ultrasound Med. Biol. , vol.24 , pp. 689-695
    • Wear, K.A.1    Garra, B.S.2
  • 57
    • 0034976172 scopus 로고    scopus 로고
    • Ultrasonic backscatter and transmission parameters at the os calcis in postmenopausal osteoporosis
    • C. R. Roux, V. Roberjot, R. Porcher, S. Kolta, M. Dougados, and P. Laugier, "Ultrasonic backscatter and transmission parameters at the os calcis in postmenopausal osteoporosis," J. Bone Mineral Res., vol. 16, pp. 1353-1362, 2001.
    • (2001) J. Bone Mineral Res. , vol.16 , pp. 1353-1362
    • Roux, C.R.1    Roberjot, V.2    Porcher, R.3    Kolta, S.4    Dougados, M.5    Laugier, P.6
  • 58
    • 0034109175 scopus 로고    scopus 로고
    • Low megahertz ultrasonic properties of bovine cancellous bone
    • B. K. Hoffmeister, S. A. Whitten, and J. Y. Rho, "Low megahertz ultrasonic properties of bovine cancellous bone," Bone, vol. 26, pp. 635-642, 2000.
    • (2000) Bone , vol.26 , pp. 635-642
    • Hoffmeister, B.K.1    Whitten, S.A.2    Rho, J.Y.3
  • 59
    • 0036226159 scopus 로고    scopus 로고
    • Bone marrow influences quantitative ultrasound measurements in human cancelous bone
    • P. H. F. Nicholson and M. L. Bouxsein, "Bone marrow influences quantitative ultrasound measurements in human cancelous bone," Ultrasound Med. Biol., vol. 28, no. 3, pp. 369-375, 2002.
    • (2002) Ultrasound Med. Biol. , vol.28 , Issue.3 , pp. 369-375
    • Nicholson, P.H.F.1    Bouxsein, M.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.