메뉴 건너뛰기




Volumn 92, Issue 1, 2003, Pages 5-10

Impact of moderate lesion calcium on mechanisms of coronary stenting as assessed with three-dimensional intravascular ultrasound in vivo

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM;

EID: 0037524351     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(03)00455-7     Document Type: Article
Times cited : (25)

References (30)
  • 5
    • 0031018844 scopus 로고    scopus 로고
    • Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents: In-stent neointimal proliferation without significant reference segment response
    • Mudra H., Regar E., Klauss V., Werner F., Henneke K.-H., Sbarouni E., Theisen K. Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents in-stent neointimal proliferation without significant reference segment response . Circulation. 95:1997;363-370.
    • (1997) Circulation , vol.95 , pp. 363-370
    • Mudra, H.1    Regar, E.2    Klauss, V.3    Werner, F.4    Henneke, K.-H.5    Sbarouni, E.6    Theisen, K.7
  • 6
    • 0029902667 scopus 로고    scopus 로고
    • Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: Online observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance
    • von Birgelen C., Gil R., Ruygrok P., Prati F., Di Mario C., van der Giessen W.J., de Feyter P.J., Serruys P.W. Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent online observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance . Am Heart J. 131:1996;1067-1075.
    • (1996) Am Heart J , vol.131 , pp. 1067-1075
    • Von Birgelen, C.1    Gil, R.2    Ruygrok, P.3    Prati, F.4    Di Mario, C.5    Van Der Giessen, W.J.6    De Feyter, P.J.7    Serruys, P.W.8
  • 8
    • 0036554783 scopus 로고    scopus 로고
    • The stent is here to stay: A note on stenting, ultrasound imaging, and the prevention of restenosis
    • von Birgelen C., Erbel R. The stent is here to stay a note on stenting, ultrasound imaging, and the prevention of restenosis . Eur Heart J. 23:2002;595-597.
    • (2002) Eur Heart J , vol.23 , pp. 595-597
    • Von Birgelen, C.1    Erbel, R.2
  • 12
    • 0032528197 scopus 로고    scopus 로고
    • Coronary Wallstents show significant late, post-procedural expansion despite implantation with adjunct high-pressure balloon inflations
    • von Birgelen C., Airiian S.G., de Feyter P.J., Foley D.P., van der Giessen W.J., Serruys P.W. Coronary Wallstents show significant late, post-procedural expansion despite implantation with adjunct high-pressure balloon inflations. Am J Cardiol. 82:1998;129-134.
    • (1998) Am J Cardiol , vol.82 , pp. 129-134
    • Von Birgelen, C.1    Airiian, S.G.2    De Feyter, P.J.3    Foley, D.P.4    Van Der Giessen, W.J.5    Serruys, P.W.6
  • 13
    • 0026627853 scopus 로고
    • Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound
    • Fitzgerald P.J., Ports T.A., Yock P.G. Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound. Circulation. 86:1992;64-70.
    • (1992) Circulation , vol.86 , pp. 64-70
    • Fitzgerald, P.J.1    Ports, T.A.2    Yock, P.G.3
  • 14
    • 0031027775 scopus 로고    scopus 로고
    • Determinants and correlates of target lesion calcium in coronary artery disease: A clinical, angiographic and intravascular ultrasound study
    • Mintz G.S., Pichard A.D., Popma J.J., Kent K.M., Satler L.F., Bucher T.A., Leon M.B. Determinants and correlates of target lesion calcium in coronary artery disease a clinical, angiographic and intravascular ultrasound study . J Am Coll Cardiol. 29:1997;268-274.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 268-274
    • Mintz, G.S.1    Pichard, A.D.2    Popma, J.J.3    Kent, K.M.4    Satler, L.F.5    Bucher, T.A.6    Leon, M.B.7
  • 16
    • 0033011046 scopus 로고    scopus 로고
    • Calcified plaque cross-sectional area in human arteries: Correlation between intravascular ultrasound and undecalcified histology
    • Kostamaa H., Donovan J., Kasaoka S., Tobis J., Fitzpatrick L. Calcified plaque cross-sectional area in human arteries correlation between intravascular ultrasound and undecalcified histology . Am Heart J. 137:1999;482-488.
    • (1999) Am Heart J , vol.137 , pp. 482-488
    • Kostamaa, H.1    Donovan, J.2    Kasaoka, S.3    Tobis, J.4    Fitzpatrick, L.5
  • 17
    • 0029957768 scopus 로고    scopus 로고
    • Coronary plaque morphology affects stent deployment: Assessment by intracoronary ultrasound
    • Albrecht D., Kaspers S., Fuessl R., Hoepp H.W., Sechtem U. Coronary plaque morphology affects stent deployment assessment by intracoronary ultrasound . Cathet Cardiovasc Diagn. 38:1996;229-235.
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 229-235
    • Albrecht, D.1    Kaspers, S.2    Fuessl, R.3    Hoepp, H.W.4    Sechtem, U.5
  • 18
    • 0030031610 scopus 로고    scopus 로고
    • A word of caution on optimizing stent deployment in calcified lesions: A case of acute coronary rupture with cardiac tamponade
    • Reimers B., von Birgelen C., van der Giessen W.J., Serruys P.W. A word of caution on optimizing stent deployment in calcified lesions a case of acute coronary rupture with cardiac tamponade . Am Heart J. 131:1996;192-194.
    • (1996) Am Heart J , vol.131 , pp. 192-194
    • Reimers, B.1    Von Birgelen, C.2    Van Der Giessen, W.J.3    Serruys, P.W.4
  • 21
    • 0029962637 scopus 로고    scopus 로고
    • Morphometric analysis in three-dimensional intracoronary ultrasound: An in-vitro and in-vivo study using a novel system for the contour detection of lumen and plaque
    • von Birgelen C., Di Mario C., Li W., Schuurbiers J.C.H., Slager C.J., de Feyter P.J., Roelandt J.R.T.C., Serruys P.W. Morphometric analysis in three-dimensional intracoronary ultrasound an in-vitro and in-vivo study using a novel system for the contour detection of lumen and plaque . Am Heart J. 132:1996;516-527.
    • (1996) Am Heart J , vol.132 , pp. 516-527
    • Von Birgelen, C.1    Di Mario, C.2    Li, W.3    Schuurbiers, J.C.H.4    Slager, C.J.5    De Feyter, P.J.6    Roelandt, J.R.T.C.7    Serruys, P.W.8
  • 22
    • 0030671369 scopus 로고    scopus 로고
    • ECG-gated three-dimensional intravascular ultrasound: Feasibility and reproducibility of an automated analysis of coronary lumen and atherosclerotic plaque dimensions
    • von Birgelen C., de Vrey E.A., Mintz G.S., Nicosia A., Bruining N., Li W., Slager C.J., Roelandt J.R.T.C., Serruys P.W., de Feyter P.J. ECG-gated three-dimensional intravascular ultrasound feasibility and reproducibility of an automated analysis of coronary lumen and atherosclerotic plaque dimensions . Circulation. 96:1997;2944-2952.
    • (1997) Circulation , vol.96 , pp. 2944-2952
    • Von Birgelen, C.1    De Vrey, E.A.2    Mintz, G.S.3    Nicosia, A.4    Bruining, N.5    Li, W.6    Slager, C.J.7    Roelandt, J.R.T.C.8    Serruys, P.W.9    De Feyter, P.J.10
  • 23
    • 0029891485 scopus 로고    scopus 로고
    • Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis: An in vivo intravascular ultrasound study
    • Nishioka T., Luo H., Eigler N.L., Berglund H., Kim C.J., Siegel R.J. Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis an in vivo intravascular ultrasound study . J Am Coll Cardiol. 27:1996;1571-1576.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1571-1576
    • Nishioka, T.1    Luo, H.2    Eigler, N.L.3    Berglund, H.4    Kim, C.J.5    Siegel, R.J.6
  • 24
    • 0030897077 scopus 로고    scopus 로고
    • Contribution of inadequate arterial remodeling to the development of focal coronary artery stenoses: An intravascular ultrasound study
    • Mintz G.S., Kent K.M., Pichard A.D., Satler L.F., Popma J.J., Leon M.B. Contribution of inadequate arterial remodeling to the development of focal coronary artery stenoses an intravascular ultrasound study . Circulation. 95:1997;1791-1798.
    • (1997) Circulation , vol.95 , pp. 1791-1798
    • Mintz, G.S.1    Kent, K.M.2    Pichard, A.D.3    Satler, L.F.4    Popma, J.J.5    Leon, M.B.6
  • 26
    • 0030029272 scopus 로고    scopus 로고
    • Axial plaque redistribution as a mechanism of percutaneous transluminal coronary angioplasty
    • Mintz G.S., Pichard A.D., Kent K.M., Satler L.F., Popma J.J., Leon M.B. Axial plaque redistribution as a mechanism of percutaneous transluminal coronary angioplasty. Am J Cardiol. 77:1996;427-430.
    • (1996) Am J Cardiol , vol.77 , pp. 427-430
    • Mintz, G.S.1    Pichard, A.D.2    Kent, K.M.3    Satler, L.F.4    Popma, J.J.5    Leon, M.B.6
  • 27
    • 0034604231 scopus 로고    scopus 로고
    • Mechanism of lumen enlargement during intracoronary stent implantation: An intravascular ultrasound study
    • Ahmed J.M., Mintz G.S., Weissman N.J., Lansky A.J., Pichard A.D., Satler L.F., Kent K.M. Mechanism of lumen enlargement during intracoronary stent implantation an intravascular ultrasound study . Circulation. 102:2000;7-10.
    • (2000) Circulation , vol.102 , pp. 7-10
    • Ahmed, J.M.1    Mintz, G.S.2    Weissman, N.J.3    Lansky, A.J.4    Pichard, A.D.5    Satler, L.F.6    Kent, K.M.7
  • 29
    • 0032799409 scopus 로고    scopus 로고
    • Quantitative changes in reference segments during IVUS-guided stent implantation: Impact on the criteria for optimal stent expansion
    • Regar E., Klauss V., Werner F., Henneke K.H., Rieber J., Konig A., Theisen K., Mudra H. Quantitative changes in reference segments during IVUS-guided stent implantation impact on the criteria for optimal stent expansion . Cathet Cardiovasc Intervent. 47:1999;434-440.
    • (1999) Cathet Cardiovasc Intervent , vol.47 , pp. 434-440
    • Regar, E.1    Klauss, V.2    Werner, F.3    Henneke, K.H.4    Rieber, J.5    Konig, A.6    Theisen, K.7    Mudra, H.8
  • 30
    • 0035889461 scopus 로고    scopus 로고
    • Comparison of luminal enlargement by direct coronary stenting versus predilatation coronary stenting by three-dimensional volumetric intravascular ultrasound analysis
    • Finet G., Weissman N.J., Mintz G.S., Satler L.F., Kent K.M., Castagna M.T., Ajani A.E., Pichard A.D. Comparison of luminal enlargement by direct coronary stenting versus predilatation coronary stenting by three-dimensional volumetric intravascular ultrasound analysis. Am J Cardiol. 88:2001;1179-1182.
    • (2001) Am J Cardiol , vol.88 , pp. 1179-1182
    • Finet, G.1    Weissman, N.J.2    Mintz, G.S.3    Satler, L.F.4    Kent, K.M.5    Castagna, M.T.6    Ajani, A.E.7    Pichard, A.D.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.