메뉴 건너뛰기




Volumn 131, Issue 6, 1996, Pages 1067-1075

Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: On-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BLOOD FLOWMETRY; CLINICAL ARTICLE; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY DILATATION; FEMALE; HUMAN; HUMAN CELL; HUMAN TISSUE; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; STENT; SURGICAL EQUIPMENT; THREE DIMENSIONAL IMAGING; TREATMENT FAILURE;

EID: 0029902667     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(96)90078-2     Document Type: Article
Times cited : (52)

References (55)
  • 1
    • 0027527078 scopus 로고
    • A novel strategy for stent deployment in the treatment of acute or threatened closure complicating balloon coronary angioplasty: Use of a short or standard (or both) single or multiple Palmaz-Schatz stents
    • Colombo A, Goldberg SL, Almagor Y, Maiello L, Finci L. A novel strategy for stent deployment in the treatment of acute or threatened closure complicating balloon coronary angioplasty: use of a short or standard (or both) single or multiple Palmaz-Schatz stents. J Am Coll Cardiol 1993;22:1887-91.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1887-1891
    • Colombo, A.1    Goldberg, S.L.2    Almagor, Y.3    Maiello, L.4    Finci, L.5
  • 3
    • 0026038878 scopus 로고
    • Effect of intracoronary stenting on intimai dissection after balloon angioplasty: Results of quantitative coronary analysis
    • Fishman DL, Savage MP, Leon MB, Schatz RA, Ellis SG, Cleman MW, et al. Effect of intracoronary stenting on intimai dissection after balloon angioplasty: results of quantitative coronary analysis. J Am Coll Cardiol 1991;18:1445-51.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1445-1451
    • Fishman, D.L.1    Savage, M.P.2    Leon, M.B.3    Schatz, R.A.4    Ellis, S.G.5    Cleman, M.W.6
  • 4
    • 0027195816 scopus 로고
    • Multicenter investigation of coronary stenting to treat accute or threatened closure after percutaneous transluminal coronary angioplasty: Clinical and angiographic outcomes
    • George BS, Voorhees WD, Roubin GS, Fearnot NE, Pinkerton CA, Raizner AF, et al. Multicenter investigation of coronary stenting to treat accute or threatened closure after percutaneous transluminal coronary angioplasty: clinical and angiographic outcomes. J Am Coll Cardiol 1993;22:135-43.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 135-143
    • George, B.S.1    Voorhees, W.D.2    Roubin, G.S.3    Fearnot, N.E.4    Pinkerton, C.A.5    Raizner, A.F.6
  • 5
    • 0025878067 scopus 로고
    • Results of intracoronary stents for management of coronary dissection after balloon angioplasty
    • Haude M, Erbel R, Straub U, Dietz U, Schatz R, Meyer J. Results of intracoronary stents for management of coronary dissection after balloon angioplasty. Am J Cardiol 1991;67:691-6.
    • (1991) Am J Cardiol , vol.67 , pp. 691-696
    • Haude, M.1    Erbel, R.2    Straub, U.3    Dietz, U.4    Schatz, R.5    Meyer, J.6
  • 6
    • 0026802432 scopus 로고
    • Emergent use of balloon-expandable coronary artery stenting for failed percutaneous transluminal coronary angioplasty
    • Herrman HC, Buchbinder M, Clemen MW, Fishman D, Goldberg S, Leon MB, et al. Emergent use of balloon-expandable coronary artery stenting for failed percutaneous transluminal coronary angioplasty. Circulation 1992;86:812-9.
    • (1992) Circulation , vol.86 , pp. 812-819
    • Herrman, H.C.1    Buchbinder, M.2    Clemen, M.W.3    Fishman, D.4    Goldberg, S.5    Leon, M.B.6
  • 7
    • 0027212848 scopus 로고
    • Coronary stenting for treatment of acute or threatened closure following dissection after coronary balloon angioplasty
    • Maiello L, Colombo A, Gianrossi R, McCanny R, Finci L. Coronary stenting for treatment of acute or threatened closure following dissection after coronary balloon angioplasty. Am Heart J 1993;125: 1570-5.
    • (1993) Am Heart J , vol.125 , pp. 1570-1575
    • Maiello, L.1    Colombo, A.2    Gianrossi, R.3    McCanny, R.4    Finci, L.5
  • 8
    • 0026507461 scopus 로고
    • Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty
    • Roubin GS, Cannon AD, Agrawal SK, Macander PJ, Dean LS, Baxley WA, et al. Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty. Circulation 1992;85:916-27.
    • (1992) Circulation , vol.85 , pp. 916-927
    • Roubin, G.S.1    Cannon, A.D.2    Agrawal, S.K.3    Macander, P.J.4    Dean, L.S.5    Baxley, W.A.6
  • 9
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987;316:701-6.
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3    Joffre, F.4    Kappenberger, L.5
  • 11
    • 0028912131 scopus 로고
    • Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
    • Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, et al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 1995;91:1676-88.
    • (1995) Circulation , vol.91 , pp. 1676-1688
    • Colombo, A.1    Hall, P.2    Nakamura, S.3    Almagor, Y.4    Maiello, L.5    Martini, G.6
  • 14
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fishman DL, Leon MB, Bairn DS, Schatz RA, Savage MP, Penn I, et al. for the Stent REStenosisi Study (STRESS) Investigators. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994;331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fishman, D.L.1    Leon, M.B.2    Bairn, D.S.3    Schatz, R.A.4    Savage, M.P.5    Penn, I.6
  • 15
    • 0028123099 scopus 로고
    • A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Hendrickx G, et al. for the Benestent Study Group. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 1994;331:489-95.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneij, F.3    Macaya, C.4    Rutsch, W.5    Hendrickx, G.6
  • 16
    • 0027208065 scopus 로고
    • Subacute thrombotic complications after intracoronary implantation of Palmaz-Schatz stents
    • Haude M, Erbel R, Issa H, Straub U, Rupprecht HJ, Treese N, et al. Subacute thrombotic complications after intracoronary implantation of Palmaz-Schatz stents. Am Heart J 1993;126:15-22.
    • (1993) Am Heart J , vol.126 , pp. 15-22
    • Haude, M.1    Erbel, R.2    Issa, H.3    Straub, U.4    Rupprecht, H.J.5    Treese, N.6
  • 17
    • 0030031610 scopus 로고    scopus 로고
    • A word of caution on optimizing stent deployment in calcified lesions: A case of acute coronary rupture with cardiac tamponade
    • Reimers B, von Birgelen C, van der Giessen WJ, Serruys PW. A word of caution on optimizing stent deployment in calcified lesions: a case of acute coronary rupture with cardiac tamponade. Am Heart J 1996;131:192-4.
    • (1996) Am Heart J , vol.131 , pp. 192-194
    • Reimers, B.1    Von Birgelen, C.2    Van Der Giessen, W.J.3    Serruys, P.W.4
  • 18
    • 0026514585 scopus 로고
    • Quantitative angiographic follow-up of the coronary Wallstent in native vessels and bypass grafts (European experience - March 1986 to March 1990)
    • Strauss BH, Serruys PW, Bertrand ME, Puel J, Meier B, Goy JJ, et al. Quantitative angiographic follow-up of the coronary Wallstent in native vessels and bypass grafts (European experience - March 1986 to March 1990). Am J Cardiol 1992;69:475-81.
    • (1992) Am J Cardiol , vol.69 , pp. 475-481
    • Strauss, B.H.1    Serruys, P.W.2    Bertrand, M.E.3    Puel, J.4    Meier, B.5    Goy, J.J.6
  • 19
    • 0028701580 scopus 로고
    • Clinical and angiographic outcome following implantation of the less shortening Wallstent in aorto-coronary vein grafts: Introduction of a second generation stent in the clinical arena
    • Keane D, Buis B, Reifart N, Plokker TH, Ernst J, Mast E, et al. Clinical and angiographic outcome following implantation of the less shortening Wallstent in aorto-coronary vein grafts: introduction of a second generation stent in the clinical arena. J Interven Cardiol 1994;7:557-64.
    • (1994) J Interven Cardiol , vol.7 , pp. 557-564
    • Keane, D.1    Buis, B.2    Reifart, N.3    Plokker, T.H.4    Ernst, J.5    Mast, E.6
  • 20
    • 0028051799 scopus 로고
    • Structural design, clinical experience, and current indications of the coronary Wallstent
    • Keane D, de Jaegere P, Serruys PW. Structural design, clinical experience, and current indications of the coronary Wallstent. Cardiology Clinics 1994;12:689-97.
    • (1994) Cardiology Clinics , vol.12 , pp. 689-697
    • Keane, D.1    De Jaegere, P.2    Serruys, P.W.3
  • 23
    • 0026098345 scopus 로고
    • Clinical experience with the Palmaz-Schatz coronary stent (initial results of a multicenter study)
    • Schatz RA, Baim DS, Leon M, Ellis SG, Goldberg S, Hirshfeld JW, et al. Clinical experience with the Palmaz-Schatz coronary stent (initial results of a multicenter study). Circulation 1991;83:148-61.
    • (1991) Circulation , vol.83 , pp. 148-161
    • Schatz, R.A.1    Baim, D.S.2    Leon, M.3    Ellis, S.G.4    Goldberg, S.5    Hirshfeld, J.W.6
  • 24
    • 0025953720 scopus 로고
    • Short and long term results after intracoronary stenting in human coronary arteries: Monocenter experience with the balloon-expandable Palmaz-Schatz stent
    • Haude M, Erbel R, Straub U, Dietz U, Meyer J. Short and long term results after intracoronary stenting in human coronary arteries: monocenter experience with the balloon-expandable Palmaz-Schatz stent. Br Heart J 1991;66:337-45.
    • (1991) Br Heart J , vol.66 , pp. 337-345
    • Haude, M.1    Erbel, R.2    Straub, U.3    Dietz, U.4    Meyer, J.5
  • 25
    • 0029059034 scopus 로고
    • Three-dimensional reconstruction of two-dimensional intracoronary ultrasound: Clinical or research tool?
    • Di Mario C, von Birgelen C, Prati F, Soni B, Li W, Bruining N, et al. Three-dimensional reconstruction of two-dimensional intracoronary ultrasound: clinical or research tool? Br Heart J 1995;73(2 Suppl):26-32.
    • (1995) Br Heart J , vol.73 , Issue.2 SUPPL. , pp. 26-32
    • Di Mario, C.1    Von Birgelen, C.2    Prati, F.3    Soni, B.4    Li, W.5    Bruining, N.6
  • 26
    • 0028110009 scopus 로고
    • Coronary artery lumen volume measurement using three-dimensional intravascular ultrasound: Validation of a new technique
    • Matar FA, Mintz GS, Douek P, Farb A, Virmani R, Javier SP, et al. Coronary artery lumen volume measurement using three-dimensional intravascular ultrasound: validation of a new technique. Cathet Cardiovasc Diagn 1994;33:214-20.
    • (1994) Cathet Cardiovasc Diagn , vol.33 , pp. 214-220
    • Matar, F.A.1    Mintz, G.S.2    Douek, P.3    Farb, A.4    Virmani, R.5    Javier, S.P.6
  • 27
    • 0028105943 scopus 로고
    • Three-dimensional reconstruction of intracoronary ultrasound images: Rationale, approaches, problems, and directions
    • Roelandt JRTC, Di Mario C, Pandian NG, Li W, Keane D, Slager CJ, et al. Three-dimensional reconstruction of intracoronary ultrasound images: rationale, approaches, problems, and directions. Circulation 1994;90:1044-55.
    • (1994) Circulation , vol.90 , pp. 1044-1055
    • Roelandt, J.R.T.C.1    Di Mario, C.2    Pandian, N.G.3    Li, W.4    Keane, D.5    Slager, C.J.6
  • 28
    • 0026005798 scopus 로고
    • Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination
    • Rosenfield K, Losordo DW, Ramaswamy K, Pastore JO, Langevin E, Razvi S, et al. Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination. Circulation 1991;84:1938-56.
    • (1991) Circulation , vol.84 , pp. 1938-1956
    • Rosenfield, K.1    Losordo, D.W.2    Ramaswamy, K.3    Pastore, J.O.4    Langevin, E.5    Razvi, S.6
  • 29
    • 12844256222 scopus 로고
    • Intracoronary ultrasound: Three-dimensional reconstruction techniques
    • de Feyter PJ, Di Mario C, Serruys PW, editors. Rotterdam: Barjesteh Meeuwes
    • von Birgelen C, Di Mario C, Prati F, Bruining N, Li W, de Feyter PJ, et al. Intracoronary ultrasound: three-dimensional reconstruction techniques. In: de Feyter PJ, Di Mario C, Serruys PW, editors. Quantitative coronary imaging. Rotterdam: Barjesteh Meeuwes, 1995:181-97.
    • (1995) Quantitative Coronary Imaging , pp. 181-197
    • Von Birgelen, C.1    Di Mario, C.2    Prati, F.3    Bruining, N.4    Li, W.5    De Feyter, P.J.6
  • 30
    • 0027488552 scopus 로고
    • Three-dimensional intravascular ultrasonography: Reconstruction of endovascular stents in vitro and in vivo
    • Mintz GS, Pichard AD, Satler LF, Popma JJ, Kent KM, Leon MB. Three-dimensional intravascular ultrasonography: reconstruction of endovascular stents in vitro and in vivo. Clin Ultrasound 1993;21:609-15.
    • (1993) Clin Ultrasound , vol.21 , pp. 609-615
    • Mintz, G.S.1    Pichard, A.D.2    Satler, L.F.3    Popma, J.J.4    Kent, K.M.5    Leon, M.B.6
  • 31
    • 0027081783 scopus 로고
    • Use of intracoronary ultrasound to identify the "true" coronary lumen in chronic coronary dissection treated with intracoronary stenting
    • Schryver TE, Popma JJ, Kent KM, Leon MB, Eldredge S, Mintz GS. Use of intracoronary ultrasound to identify the "true" coronary lumen in chronic coronary dissection treated with intracoronary stenting. Am J Cardiol 1992;69:1107-8.
    • (1992) Am J Cardiol , vol.69 , pp. 1107-1108
    • Schryver, T.E.1    Popma, J.J.2    Kent, K.M.3    Leon, M.B.4    Eldredge, S.5    Mintz, G.S.6
  • 32
    • 0028106302 scopus 로고
    • Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter
    • Mudra H, Klauss V, Blasini R, Kroetz M, Rieber J, Regar E, et al. Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter. Circulation 1994;90:1252-61.
    • (1994) Circulation , vol.90 , pp. 1252-1261
    • Mudra, H.1    Klauss, V.2    Blasini, R.3    Kroetz, M.4    Rieber, J.5    Regar, E.6
  • 33
    • 0028947782 scopus 로고
    • Serial intravascular ultrasound studies fail to show evidence of chronic Palmaz-Schatz stent recoil
    • Painter JA, Mintz GS, Wong SC, Popma JJ, Pichard AD, Kent KM, et al. Serial intravascular ultrasound studies fail to show evidence of chronic Palmaz-Schatz stent recoil. Am J Cardiol 1995;75:398-400.
    • (1995) Am J Cardiol , vol.75 , pp. 398-400
    • Painter, J.A.1    Mintz, G.S.2    Wong, S.C.3    Popma, J.J.4    Pichard, A.D.5    Kent, K.M.6
  • 34
    • 0028916334 scopus 로고
    • Mode of deployment of coronary Palmaz-Schatz stents after implantation with the stent delivery system: An intravascular ultrasound study
    • Kiemeneij F, Laarman GJ, Slagboom T. Mode of deployment of coronary Palmaz-Schatz stents after implantation with the stent delivery system: an intravascular ultrasound study. Am Heart J 1995;123:638-44.
    • (1995) Am Heart J , vol.123 , pp. 638-644
    • Kiemeneij, F.1    Laarman, G.J.2    Slagboom, T.3
  • 35
  • 37
    • 0025542168 scopus 로고
    • Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease
    • Ellis SG, Vandormael MG, Cowley MJ, Di Sciascio G, Deligonul U, Topol EJ, et al. and the multivessel angioplasty prognosis group. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Circulation 1990;82:1193-202.
    • (1990) Circulation , vol.82 , pp. 1193-1202
    • Ellis, S.G.1    Vandormael, M.G.2    Cowley, M.J.3    Di Sciascio, G.4    Deligonul, U.5    Topol, E.J.6
  • 38
    • 0023724651 scopus 로고
    • Guidelines for percutaneous transluminal coronary angioplasty: A report of the American College of Cardiology/American Heart Association task force on assessment of diagnostic and therapeutic cardiovascular procedures (subcommittee on percutaneous transluminal coronary angioplasty)
    • Ryan TJ, Faxon DP, Kennedy JW, King SB III, Loop FD, Peterson KL, et al. Guidelines for percutaneous transluminal coronary angioplasty: a report of the American College of Cardiology/American Heart Association task force on assessment of diagnostic and therapeutic cardiovascular procedures (subcommittee on percutaneous transluminal coronary angioplasty). J Am Coll Cardiol 1988;12:529-45 and Circulation 1988;78:486-502.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 529-545
    • Ryan, T.J.1    Faxon, D.P.2    Kennedy, J.W.3    King III, S.B.4    Loop, F.D.5    Peterson, K.L.6
  • 39
    • 0023740319 scopus 로고
    • Ryan TJ, Faxon DP, Kennedy JW, King SB III, Loop FD, Peterson KL, et al. Guidelines for percutaneous transluminal coronary angioplasty: a report of the American College of Cardiology/American Heart Association task force on assessment of diagnostic and therapeutic cardiovascular procedures (subcommittee on percutaneous transluminal coronary angioplasty). J Am Coll Cardiol 1988;12:529-45 and Circulation 1988;78:486-502.
    • (1988) Circulation , vol.78 , pp. 486-502
  • 40
    • 0002261519 scopus 로고
    • Quantitative coronary angiography: An integral component of interventional cardiology
    • Topol EJ, Serruys PW, editors. Philadelphia: Current Medicine
    • Keane D, Serruys PW. Quantitative coronary angiography: an integral component of interventional cardiology. In: Topol EJ, Serruys PW, editors. Current review of interventional cardiology, 2nd ed. Philadelphia: Current Medicine, 1995:205-33.
    • (1995) Current Review of Interventional Cardiology, 2nd Ed. , pp. 205-233
    • Keane, D.1    Serruys, P.W.2
  • 41
    • 0027383276 scopus 로고
    • Experimental validation of geometric and densitometric coronary measurements on the new generation cardiovascular angiography analysis system
    • Haase J, Escaned J, van Swijndregt EM, Ozaki Y, Gronenschild E, Slager CJ, et al. Experimental validation of geometric and densitometric coronary measurements on the new generation cardiovascular angiography analysis system. Cathet Cardiovasc Diagn 1993;30:104-14.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , pp. 104-114
    • Haase, J.1    Escaned, J.2    Van Swijndregt, E.M.3    Ozaki, Y.4    Gronenschild, E.5    Slager, C.J.6
  • 43
    • 0026879506 scopus 로고
    • Immediate changes in stenosis geometry following stent implantation: Comparison between a self-expandable and a balloon expandable stent
    • De Jaegere PP, Strauss BH, van der Giessen WJ, de Feyter PJ, Serruys PW. Immediate changes in stenosis geometry following stent implantation: comparison between a self-expandable and a balloon expandable stent. J Interven Cardiol 1992;5:71-8.
    • (1992) J Interven Cardiol , vol.5 , pp. 71-78
    • De Jaegere, P.P.1    Strauss, B.H.2    Van Der Giessen, W.J.3    De Feyter, P.J.4    Serruys, P.W.5
  • 44
    • 0028234039 scopus 로고
    • Intravascular ultrasound imaging of angiographically normal coronary arteries: A prospective study in vivo
    • Ge J, Erbel R, Gerber T, Gorge G, Koch L, Haude M, et al. Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo. Br Heart J 1994;71:572-8.
    • (1994) Br Heart J , vol.71 , pp. 572-578
    • Ge, J.1    Erbel, R.2    Gerber, T.3    Gorge, G.4    Koch, L.5    Haude, M.6
  • 45
    • 0026009897 scopus 로고
    • Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease
    • Nissen SE, Gurley JC, Grines CL, Booth DC, McClure R, Berk M, et al. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation 1991;84:1087-99.
    • (1991) Circulation , vol.84 , pp. 1087-1099
    • Nissen, S.E.1    Gurley, J.C.2    Grines, C.L.3    Booth, D.C.4    McClure, R.5    Berk, M.6
  • 47
    • 0027441752 scopus 로고
    • Intravascular ultrasound assessment of the balloon-expandable Palmaz-Schatz coronary stent
    • Mudra H, Blasini R, Regar E, Klauss V, Rieber J, Theisen K. Intravascular ultrasound assessment of the balloon-expandable Palmaz-Schatz coronary stent. Coron Art Dis 1993;4:791-99.
    • (1993) Coron Art Dis , vol.4 , pp. 791-799
    • Mudra, H.1    Blasini, R.2    Regar, E.3    Klauss, V.4    Rieber, J.5    Theisen, K.6
  • 48
    • 0025912189 scopus 로고
    • Application of intraluminal ultrasound imaging to vascular stenting
    • Slepian MJ. Application of intraluminal ultrasound imaging to vascular stenting. Int J Card Imaging 1991;6:285-311.
    • (1991) Int J Card Imaging , vol.6 , pp. 285-311
    • Slepian, M.J.1
  • 50
    • 0028878279 scopus 로고
    • Intravascular ultrasound assessment of the magnitude and mechanism of coronary artery andlumen tapering
    • Javier SP, Mintz GS, Popma JJ, Pichard AD, Kent KM, Satler LF, et al. Intravascular ultrasound assessment of the magnitude and mechanism of coronary artery andlumen tapering. Am J Cardiol 1995;75:177-80.
    • (1995) Am J Cardiol , vol.75 , pp. 177-180
    • Javier, S.P.1    Mintz, G.S.2    Popma, J.J.3    Pichard, A.D.4    Kent, K.M.5    Satler, L.F.6
  • 51
    • 0028898306 scopus 로고
    • Can intracoronary ultrasound correctly assess the luminal dimensions of coronary artery lesions? A comparison with quantitative angiography
    • Haase J, Ozaki Y, Di Mario C, Escaned J, De Feyter PJ, Roelandt JRTC, et al. Can intracoronary ultrasound correctly assess the luminal dimensions of coronary artery lesions? A comparison with quantitative angiography. Eur Heart J 1995;16:112-9.
    • (1995) Eur Heart J , vol.16 , pp. 112-119
    • Haase, J.1    Ozaki, Y.2    Di Mario, C.3    Escaned, J.4    De Feyter, P.J.5    Roelandt, J.R.T.C.6
  • 52
  • 53
    • 0347440142 scopus 로고
    • Volumetric quantification in intracoronary ultrasound: Validation of a new automatic contour detection method with integrated user interaction
    • von Birgelen C, Di Mario C, Li W, Camenzind E, Ozaki Y, de Feyter PJ, et al. Volumetric quantification in intracoronary ultrasound: validation of a new automatic contour detection method with integrated user interaction [abstract]. Circulation 1994;90:I-550.
    • (1994) Circulation , vol.90
    • Von Birgelen, C.1    Di Mario, C.2    Li, W.3    Camenzind, E.4    Ozaki, Y.5    De Feyter, P.J.6
  • 54
    • 15844429902 scopus 로고
    • Clinical application of a new computerized method measuring coronary artery dimensions by three-dimensional intracoronary ultrasound: Reproducibility in vivo during coronary interventions
    • von Birgelen C, Di Mario C, Li W, Schuurbiers JCH, Slager Cj, Ruygrok P, et al. Clinical application of a new computerized method measuring coronary artery dimensions by three-dimensional intracoronary ultrasound: reproducibility in vivo during coronary interventions [abstract]. Eur Heart J 1995;16:428.
    • (1995) Eur Heart J , vol.16 , pp. 428
    • Von Birgelen, C.1    Di Mario, C.2    Li, W.3    Schuurbiers, J.C.H.4    Slager, Cj.5    Ruygrok, P.6
  • 55
    • 0343598007 scopus 로고
    • Automated segmentation of coronary wall and plaque from intravascular ultrasound image sequences
    • Los Alamitos, Calif.: IEEE Computer Society Press
    • Sonka M, Zhang X, Siebes M, DeJong S, McKay CR, Collins SM. Automated segmentation of coronary wall and plaque from intravascular ultrasound image sequences. In: Computers in cardiology 1994. Los Alamitos, Calif.: IEEE Computer Society Press, 1994:281-4.
    • (1994) Computers in Cardiology 1994 , pp. 281-284
    • Sonka, M.1    Zhang, X.2    Siebes, M.3    DeJong, S.4    McKay, C.R.5    Collins, S.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.