-
1
-
-
0027934377
-
A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
-
Stent Restenosis Study Investigators
-
Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 1994;331:496-501.
-
(1994)
N Engl J Med
, vol.331
, pp. 496-501
-
-
Fischman, D.L.1
Leon, M.B.2
Baim, D.S.3
-
2
-
-
0028123099
-
A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease
-
The BENESTENT Study Group
-
Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. The BENESTENT Study Group. N Engl J Med 1994;331:489-495.
-
(1994)
N Engl J Med
, vol.331
, pp. 489-495
-
-
Serruys, P.W.1
De Jaegere, P.2
Kiemeneij, F.3
-
3
-
-
0032480946
-
Coronary artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty
-
Restenosis Stent Study Group
-
Erbel R, Haude M, Hopp HW, et al. Coronary artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty. Restenosis Stent Study Group. N Engl J Med 1998;339:1672-1678.
-
(1998)
N Engl J Med
, vol.339
, pp. 1672-1678
-
-
Erbel, R.1
Haude, M.2
Hopp, H.W.3
-
4
-
-
0029817977
-
Hoop dreams. Stents without restenosis
-
Edelman ER, Rogers C. Hoop dreams. Stents without restenosis. Circulation 1996;94:1199-1202.
-
(1996)
Circulation
, vol.94
, pp. 1199-1202
-
-
Edelman, E.R.1
Rogers, C.2
-
5
-
-
0029837889
-
Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study
-
Hoffmann R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 1996;94:1247-1254.
-
(1996)
Circulation
, vol.94
, pp. 1247-1254
-
-
Hoffmann, R.1
Mintz, G.S.2
Dussaillant, G.R.3
-
6
-
-
0031005933
-
Catheter-based radiotherapy to inhibit restenosis after coronary stenting
-
Teirstein PS, Massullo V, Jani S, et al. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997;336:1697-1703.
-
(1997)
N Engl J Med
, vol.336
, pp. 1697-1703
-
-
Teirstein, P.S.1
Massullo, V.2
Jani, S.3
-
7
-
-
0034142223
-
Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
-
Teirstein PS, Massullo V, Jani S, et al. Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial. Circulation 2000;101:360-365.
-
(2000)
Circulation
, vol.101
, pp. 360-365
-
-
Teirstein, P.S.1
Massullo, V.2
Jani, S.3
-
8
-
-
0034602820
-
Short- and intermediateterm results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan Dose-Response Study
-
Albiero R, Adamian M, Kobayashi N, et al. Short- and intermediateterm results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan Dose-Response Study. Circulation 2000;101:18-26.
-
(2000)
Circulation
, vol.101
, pp. 18-26
-
-
Albiero, R.1
Adamian, M.2
Kobayashi, N.3
-
9
-
-
0034738064
-
Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents
-
Albiero R, Nishida T, Adamian M, et al. Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents. Circulation 2000;101:2454-2457.
-
(2000)
Circulation
, vol.101
, pp. 2454-2457
-
-
Albiero, R.1
Nishida, T.2
Adamian, M.3
-
10
-
-
0033600539
-
Late coronary occlusion after intracoronary brachytherapy
-
Costa MA, Sabat M, van der Giessen WJ, et al. Late coronary occlusion after intracoronary brachytherapy. Circulation 1999;100:789-792.
-
(1999)
Circulation
, vol.100
, pp. 789-792
-
-
Costa, M.A.1
Sabat, M.2
Van der Giessen, W.J.3
-
11
-
-
0001003022
-
Paclitaxel applied directly to stents inhibits neointimal growth without thrombotic complications in a porcine coronary artery model of restenosis
-
Heldman AW, Cheng L, Heller PF, et al. Paclitaxel applied directly to stents inhibits neointimal growth without thrombotic complications in a porcine coronary artery model of restenosis. Circulation 1997;96:1288.
-
(1997)
Circulation
, vol.96
, pp. 1288
-
-
Heldman, A.W.1
Cheng, L.2
Heller, P.F.3
-
12
-
-
0030785344
-
Local drug delivery systems and prevention of restenosis
-
Brieger D, Topol E. Local drug delivery systems and prevention of restenosis. Cardiovasc Res 1997;35:405-413.
-
(1997)
Cardiovasc Res
, vol.35
, pp. 405-413
-
-
Brieger, D.1
Topol, E.2
-
13
-
-
0015211527
-
Plant antitumor agents. VI. The isolation and structure of taxol, a novel antileukemic and antitumor agent from Taxus brevifolia
-
Wani MC, Taylor HL, Wall ME, et al. Plant antitumor agents. VI. The isolation and structure of taxol, a novel antileukemic and antitumor agent from Taxus brevifolia. J Am Chem Soc 1971;93:2325-2327.
-
(1971)
J Am Chem Soc
, vol.93
, pp. 2325-2327
-
-
Wani, M.C.1
Taylor, H.L.2
Wall, M.E.3
-
14
-
-
0018387446
-
Promotion of microtubule assembly in vitro by taxol
-
Schiff PB, Fant J, Horwitz SB, Promotion of microtubule assembly in vitro by taxol. Nature 1979;277:665-667.
-
(1979)
Nature
, vol.277
, pp. 665-667
-
-
Schiff, P.B.1
Fant, J.2
Horwitz, S.B.3
-
16
-
-
84994521433
-
Paclitaxel (taxol)
-
published erratum appears in N Engl J Med 1995;333:75
-
Rowinsky EK, Donehower RC. Paclitaxel (taxol), published erratum appears in N Engl J Med 1995;333:75. N Engl J Med 1995;332:1004-1014.
-
(1995)
N Engl J Med
, vol.332
, pp. 1004-1014
-
-
Rowinsky, E.K.1
Donehower, R.C.2
-
19
-
-
0027360552
-
Mechanism of mitotic block and inhibition of cell proliferation by taxol at low concentrations
-
Jordan MA, Toso RJ, Thrower D, Wilson L. Mechanism of mitotic block and inhibition of cell proliferation by taxol at low concentrations. Proc Natl Acad Sci USA 1993;90:9552-9556.
-
(1993)
Proc Natl Acad Sci USA
, vol.90
, pp. 9552-9556
-
-
Jordan, M.A.1
Toso, R.J.2
Thrower, D.3
Wilson, L.4
-
20
-
-
0028946606
-
Taxol inhibits neointimal smooth muscle cell accumulation after angioplasty in the rat
-
Sollott SJ, Cheng L, Pauly RR, et al. Taxol inhibits neointimal smooth muscle cell accumulation after angioplasty in the rat. J Clin Invest 1995;95:1869-1876.
-
(1995)
J Clin Invest
, vol.95
, pp. 1869-1876
-
-
Sollott, S.J.1
Cheng, L.2
Pauly, R.R.3
-
21
-
-
0030840892
-
Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and in vivo using local drug delivery
-
Axel DI, Kunert W, Goggelmann C, et al. Paclitaxel inhibits arterial smooth muscle cell proliferation and migration in vitro and in vivo using local drug delivery (see comments). Circulation 1997;96:636-645.
-
(1997)
Circulation
, vol.96
, pp. 636-645
-
-
Axel, D.I.1
Kunert, W.2
Goggelmann, C.3
-
22
-
-
0034718513
-
Intrapericardial paclitaxel delivery inhibits neointimal proliferation and promotes arterial enlargement after porcine coronary overstretch
-
Hou D, Rogers PI, Toleikis PM, et al. Intrapericardial paclitaxel delivery inhibits neointimal proliferation and promotes arterial enlargement after porcine coronary overstretch. Circulation 2000;102:1575-1581.
-
(2000)
Circulation
, vol.102
, pp. 1575-1581
-
-
Hou, D.1
Rogers, P.I.2
Toleikis, P.M.3
-
23
-
-
0034081030
-
Local paclitaxel delivery for the prevention of restenosis: Biological effects and efficacy in vivo
-
Herdeg C, Oberhoff M, Baumbach A, et al. Local paclitaxel delivery for the prevention of restenosis: Biological effects and efficacy in vivo. J Am Coll Cardiol 2000;35:1969-1976.
-
(2000)
J Am Coll Cardiol
, vol.35
, pp. 1969-1976
-
-
Herdeg, C.1
Oberhoff, M.2
Baumbach, A.3
-
24
-
-
0034908836
-
Local delivery of paclitaxel using the double-balloon perfusion catheter before stenting in the porcine coronary artery
-
Oberhoff M, Herdeg C, Al Ghobainy R, et al. Local delivery of paclitaxel using the double-balloon perfusion catheter before stenting in the porcine coronary artery. Cathet Cardiovasc Interv 2001;53:562-568.
-
(2001)
Cathet Cardiovasc Interv
, vol.53
, pp. 562-568
-
-
Oberhoff, M.1
Herdeg, C.2
Al Ghobainy, R.3
-
25
-
-
0033667551
-
Neointimal thickening after stent delivery of paclitaxel: Change in composition and arrest of growth over six months
-
Drachman DE, Edelman ER, Seifert P, et al. Neointimal thickening after stent delivery of paclitaxel: Change in composition and arrest of growth over six months. J Am Coll Cardiol 2000;36:2325-2332.
-
(2000)
J Am Coll Cardiol
, vol.36
, pp. 2325-2332
-
-
Drachman, D.E.1
Edelman, E.R.2
Seifert, P.3
-
26
-
-
14344268774
-
Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis
-
Heldman AW, Cheng L, Jenkins GM, et al. Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis. Circulation 2001;103:2289-2295.
-
(2001)
Circulation
, vol.103
, pp. 2289-2295
-
-
Heldman, A.W.1
Cheng, L.2
Jenkins, G.M.3
-
27
-
-
0035943063
-
Pathological analysis of local delivery of paclitaxel via a polymer-coated stent
-
Farb A, Heller PF, Shroff S, et al. Pathological analysis of local delivery of paclitaxel via a polymer-coated stent. Circulation 2001;104:473-479.
-
(2001)
Circulation
, vol.104
, pp. 473-479
-
-
Farb, A.1
Heller, P.F.2
Shroff, S.3
-
28
-
-
0035979396
-
Physiological transport forces govern govem drug distribution for stent-based delivery
-
Hwang CW, Wu D, Edelman ER. Physiological transport forces govern govem drug distribution for stent-based delivery. Circulation 2001;104:600-605.
-
(2001)
Circulation
, vol.104
, pp. 600-605
-
-
Hwang, C.W.1
Wu, D.2
Edelman, E.R.3
-
29
-
-
0034909727
-
Initial results of the Quanam drug-eluting stent (QuaDS-QP-2) registry (BARDDS) in human subjects
-
de la Fuente LM, Miano J, Mrad J, et al. Initial results of the Quanam drug-eluting stent (QuaDS-QP-2) registry (BARDDS) in human subjects. Cathet Cardiovasc Interv 2001;53:480-488.
-
(2001)
Cathet Cardiovasc Interv
, vol.53
, pp. 480-488
-
-
De la Fuente, L.M.1
Miano, J.2
Mrad, J.3
-
30
-
-
0035943094
-
Novel drug-delivery stent: Intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system
-
Honda Y, Grube E, de la Fuente ML, et al. Novel drug-delivery stent: Intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system. Circulation 2001;104:380-383.
-
(2001)
Circulation
, vol.104
, pp. 380-383
-
-
Honda, Y.1
Grube, E.2
De la Fuente, M.L.3
-
31
-
-
0002196749
-
SCORE six-month angiographic results: Improved restenosis in patients receiving the QuaDDS-QP2 drug-eluting stent compared with the control, bare stents
-
Grube E, Lansky AJ, Reifart N, et al. SCORE six-month angiographic results: Improved restenosis in patients receiving the QuaDDS-QP2 drug-eluting stent compared with the control, bare stents. J Am Coll Cardiol 2002;39(Suppl A):59A.
-
(2002)
J Am Coll Cardiol
, vol.39
, Issue.SUPPL. A
-
-
Grube, E.1
Lansky, A.J.2
Reifart, N.3
-
32
-
-
0002510617
-
The clinical effectiveness of paclitaxel-coated coronary stents for the reduction of restenosis in the ASPECT trial
-
Park SJ, Shim WH, Ho DS, et al. The clinical effectiveness of paclitaxel-coated coronary stents for the reduction of restenosis in the ASPECT trial. Circulation 2001;104(Suppl II):II-464.
-
(2001)
Circulation
, vol.104
, Issue.SUPPL. II
-
-
Park, S.J.1
Shim, W.H.2
Ho, D.S.3
-
33
-
-
0002486983
-
Local drug delivery to inhibit coronary artery restenosis: Data from the ELUTES (Evaluation of Paclitaxel Eluting Stent) clinical trial
-
Gershlick AH, De Scheerder I, Chevalier B, et al. Local drug delivery to inhibit coronary artery restenosis: Data from the ELUTES (Evaluation of Paclitaxel Eluting Stent) clinical trial. Circulation 2001;104(Suppl II):II-416.
-
(2001)
Circulation
, vol.104
, Issue.SUPPL. II
-
-
Gershlick, A.H.1
De Scheerder, I.2
Chevalier, B.3
-
34
-
-
0001965004
-
Taxus I: Prospective, randomized, double-blind comparison of NIRx stents coated with paclitaxel in a polymer carrier in de novo coronary lesions compared with uncoated controls
-
Grube E, Silber SM, Hauptmann KE. Taxus I: Prospective, randomized, double-blind comparison of NIRx stents coated with paclitaxel in a polymer carrier in de novo coronary lesions compared with uncoated controls. Circulation 2001;104(Suppl II):II-463.
-
(2001)
Circulation
, vol.104
, Issue.SUPPL. II
-
-
Grube, E.1
Silber, S.M.2
Hauptmann, K.E.3
-
35
-
-
0036787729
-
7-Hexanolytaxol-eluting stent for prevention of neointimal growth: An intravascular ultrasound analysis from the SCORE trial
-
Kataoka T, Grube E, Honda Y, et al. 7-Hexanolytaxol-eluting stent for prevention of neointimal growth: An intravascular ultrasound analysis from the SCORE trial. Circulation 2002;106:1788-1793.
-
(2002)
Circulation
, vol.106
, pp. 1788-1793
-
-
Kataoka, T.1
Grube, E.2
Honda, Y.3
-
36
-
-
24244477432
-
Intravascular ultrasound stent edge analysis following drug-eluting stent implantation: "Candy without the wrapper"
-
Kataoka T, Grube E, Hur SH, et al. Intravascular ultrasound stent edge analysis following drug-eluting stent implantation: "Candy without the wrapper". Circulation 2001;104(Suppl II):II-770.
-
(2001)
Circulation
, vol.104
, Issue.SUPPL. II
-
-
Kataoka, T.1
Grube, E.2
Hur, S.H.3
-
37
-
-
0001784168
-
Paclitaxel coating reduces in-stent restenosis: A serial volumetric intravascular ultrasound analysis
-
Hong MK, Mintz GS, Park SW, et al. Paclitaxel coating reduces in-stent restenosis: A serial volumetric intravascular ultrasound analysis. J Am Coll Cardiol 2002;39(Suppl A):38A.
-
(2002)
J Am Coll Cardiol
, vol.39
, Issue.SUPPL. A
-
-
Hong, M.K.1
Mintz, G.S.2
Park, S.W.3
-
38
-
-
24244443615
-
Lack of edge effects, late malapposition, or black holes after paclitaxel-coated stent implantation: An intravascular ultrasound study
-
Mintz GS, Hong MK, Weissman NJ, et al. Lack of edge effects, late malapposition, or black holes after paclitaxel-coated stent implantation: An intravascular ultrasound study. Am J Cardiol 2002;90(Suppl 6A):2H.
-
(2002)
Am J Cardiol
, vol.90
, Issue.SUPPL. 6A
-
-
Mintz, G.S.1
Hong, M.K.2
Weissman, N.J.3
-
39
-
-
0002196749
-
SCORE trial interim safety results: Despite efficacy, late stent thrombosis with the QuaDDS-QP2 stent
-
Grube E, Hauptmann K, Colombo A, et al. SCORE trial interim safety results: Despite efficacy, late stent thrombosis with the QuaDDS-QP2 stent. J Am Coll Cardiol 2002;39(Suppl A):38A.
-
(2002)
J Am Coll Cardiol
, vol.39
, Issue.SUPPL. A
-
-
Grube, E.1
Hauptmann, K.2
Colombo, A.3
-
40
-
-
14344271133
-
Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
-
Sousa JE, Costa MA, Abizaid AC, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation 2001;103:192-195.
-
(2001)
Circulation
, vol.103
, pp. 192-195
-
-
Sousa, J.E.1
Costa, M.A.2
Abizaid, A.C.3
-
41
-
-
0035940374
-
Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up
-
Sousa JE, Costa MA, Abizaid AC, et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up. Circulation 2001;104:2007-2011.
-
(2001)
Circulation
, vol.104
, pp. 2007-2011
-
-
Sousa, J.E.1
Costa, M.A.2
Abizaid, A.C.3
-
42
-
-
0037030658
-
A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
-
Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-1780.
-
(2002)
N Engl J Med
, vol.346
, pp. 1773-1780
-
-
Morice, M.C.1
Serruys, P.W.2
Sousa, J.E.3
-
43
-
-
4243896592
-
Effect of sirolimus-eluting stents on neointimal hyperplasia: A serial in-stent intravascular ultrasound interim analysis from the SIRIUS trial
-
Ako J, Morino Y, Sonoda S, et al. Effect of sirolimus-eluting stents on neointimal hyperplasia: A serial in-stent intravascular ultrasound interim analysis from the SIRIUS trial. Am J Cardiol 2002;90(Suppl 6A):2H.
-
(2002)
Am J Cardiol
, vol.90
, Issue.SUPPL. 6A
-
-
Ako, J.1
Morino, Y.2
Sonoda, S.3
-
44
-
-
0037072467
-
Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (Randomized study with the sirolimus-eluting Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial
-
Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (Randomized study with the sirolimus-eluting Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002;106:798-803.
-
(2002)
Circulation
, vol.106
, pp. 798-803
-
-
Serruys, P.W.1
Degertekin, M.2
Tanabe, K.3
|