메뉴 건너뛰기




Volumn 30, Issue 3, 2003, Pages 348-351

Automatic verification of step-and-shoot IMRT field segments using portal imaging

Author keywords

Electronic portal imaging device; IMRT; Quality assurance; Step and shoot

Indexed keywords

COMPUTER HARDWARE; QUALITY ASSURANCE;

EID: 0037339705     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1544680     Document Type: Article
Times cited : (4)

References (7)
  • 1
    • 0030767978 scopus 로고    scopus 로고
    • Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system
    • L. Ma, P. B. Geis, and A. L. Boyer, "Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system," Med. Phys. 24, 1213-1220 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1213-1220
    • Ma, L.1    Geis, P.B.2    Boyer, A.L.3
  • 2
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique
    • M. Patridge, P. M. Evans, A. Mosleh-Shirazi, and D. Convey, "Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique," Med. Phys. 25, 1872-1879 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1872-1879
    • Patridge, M.1    Evans, P.M.2    Mosleh-Shirazi, A.3    Convey, D.4
  • 3
    • 0033867804 scopus 로고    scopus 로고
    • Leaf position verification during dynamic beam delivery: A comparison of three applications using electronic portal imaging
    • M. Partridge, P. M. Evans, M. van Herk, L. S. Ploeger, G. J. Budgell, and H. V. James, "Leaf position verification during dynamic beam delivery: A comparison of three applications using electronic portal imaging," Med. Phys. 27, 1601-1609 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1601-1609
    • Partridge, M.1    Evans, P.M.2    Van Herk, M.3    Ploeger, L.S.4    Budgell, G.J.5    James, H.V.6
  • 4
    • 0033796474 scopus 로고    scopus 로고
    • Computer verification of fluence map for intensity modulated radiation therapy
    • L. Xing and J. G. Li, "Computer verification of fluence map for intensity modulated radiation therapy," Med. Phys. 27, 2084-2092 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2084-2092
    • Xing, L.1    Li, J.G.2
  • 5
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • H. V. James, S. Ahterton, G. J. Budgell, M. C. Kirby, and P. C. Williams, "Verification of dynamic multileaf collimation using an electronic portal imaging device," Phys. Med. Biol. 45, 495-509 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 495-509
    • James, H.V.1    Ahterton, S.2    Budgell, G.J.3    Kirby, M.C.4    Williams, P.C.5
  • 6
    • 0035989982 scopus 로고    scopus 로고
    • A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device
    • L. S. Ploeger, M. H. P. Smitsmans, K. G. A. Gilhuijs, and M. van Herk, "A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device," Med. Phys. 29, 1071-1079 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1071-1079
    • Ploeger, L.S.1    Smitsmans, M.H.P.2    Gilhuijs, K.G.A.3    Van Herk, M.4
  • 7
    • 0032934417 scopus 로고    scopus 로고
    • Verification of segmented beam delivery using a commercial electronic portal imaging device
    • A. J. Curtin-Savard and E. B. Podgorsak, "Verification of segmented beam delivery using a commercial electronic portal imaging device," Med. Phys. 26, 737-742 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 737-742
    • Curtin-Savard, A.J.1    Podgorsak, E.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.