메뉴 건너뛰기




Volumn 27, Issue 9, 2000, Pages 2084-2092

Computer verification of fluence map for intensity modulated radiation therapy

Author keywords

IMRT; Intensity modulation; Leaf sequences; Multileaf collimator; Treatment verification

Indexed keywords

BIOMEDICAL ENGINEERING; COMPUTER MUSIC; QUALITY ASSURANCE;

EID: 0033796474     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1289374     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 0019970864 scopus 로고
    • Solution of an integral equation encountered in rotation therapy
    • A. Brahme, J. E. Roos, and I. Lax, "Solution of an integral equation encountered in rotation therapy," Phys. Med. Biol. 27, 1221-1229 (1982).
    • (1982) Phys. Med. Biol , vol.27 , pp. 1221-1229
    • Brahme, A.1    Roos, J.E.2    Lax, I.3
  • 2
    • 0025103658 scopus 로고
    • Methods of image reconstruction from projections applied to conformation therapy
    • T. Bortfeld, J. Urkelbach, R. Boesecke, and W. Schlegel, "Methods of image reconstruction from projections applied to conformation therapy," Phys. Med. Biol. 35, 1423-1434 (1990).
    • (1990) Phys. Med. Biol. , vol.35 , pp. 1423-1434
    • Bortfeld, T.1    Urkelbach, J.2    Boesecke, R.3    Schlegel, W.4
  • 4
    • 0029780422 scopus 로고    scopus 로고
    • Iterative methods for inverse treatment planning
    • L. Xing and G. Chen, "Iterative methods for inverse treatment planning," Phys. Med. Biol. 41, 2107-2123 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2107-2123
    • Xing, L.1    Chen, G.2
  • 5
    • 0031732963 scopus 로고    scopus 로고
    • Fast iterative algorithms for three-dimensional inverse treatment planning
    • L. Xing, R. J. Hamilton, D. Spelbring, C. A. Pelizzari, and G. Chen, "Fast iterative algorithms for three-dimensional inverse treatment planning," Med. Phys. 25, 1845-1849 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1845-1849
    • Xing, L.1    Hamilton, R.J.2    Spelbring, D.3    Pelizzari, C.A.4    Chen, G.5
  • 7
    • 0031895424 scopus 로고    scopus 로고
    • A gradient inverse planning algorithm with dose-volume constraints
    • S. V. Spirou and C. S. Chui, "A gradient inverse planning algorithm with dose-volume constraints," Med. Phys. 25, 321-333 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 321-333
    • Spirou, S.V.1    Chui, C.S.2
  • 8
    • 0032692577 scopus 로고    scopus 로고
    • Estimation theory and model parameter selection for therapeutic plan optimization
    • L. Xing, J. Li, A. Pugachev, Q. T. Le, and A. L. Boyer, "Estimation theory and model parameter selection for therapeutic plan optimization," Med. Phys. 26, 2348-2358 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2348-2358
    • Xing, L.1    Li, J.2    Pugachev, A.3    Le, Q.T.4    Boyer, A.L.5
  • 9
    • 0033962674 scopus 로고    scopus 로고
    • Hardware-sensitive optimization for intensity modulated radiotherapy
    • P. Cho and R. J. Marks, "Hardware-sensitive optimization for intensity modulated radiotherapy," Phys. Med. Biol. 45, 429-440 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 429-440
    • Cho, P.1    Marks, R.J.2
  • 10
    • 0026661373 scopus 로고
    • The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation
    • D. J. Convery and M. E. Rosenbloom, "The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation," Phys. Med. Biol. 37, 1359-1374 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1359-1374
    • Convery, D.J.1    Rosenbloom, M.E.2
  • 12
    • 0028144837 scopus 로고
    • Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators
    • S. V. Spirou and C. Chui, "Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators," Int. J. Radiat. Oncol., Biol., Phys. 21, 1031-1041 (1994).
    • (1994) Int. J. Radiat. Oncol., Biol., Phys. , vol.21 , pp. 1031-1041
    • Spirou, S.V.1    Chui, C.2
  • 14
    • 0002044849 scopus 로고    scopus 로고
    • Beam Shaping and Intensity Modulation
    • edited by J. Van Dyk Medical Physics, Madison, WI
    • A. L. Boyer, L. Xing, and P. Xia, "Beam Shaping and Intensity Modulation," in Modern Technology of Radiation Oncology, edited by J. Van Dyk (Medical Physics, Madison, WI, 1999).
    • (1999) Modern Technology of Radiation Oncology
    • Boyer, A.L.1    Xing, L.2    Xia, P.3
  • 15
    • 0032934417 scopus 로고    scopus 로고
    • Verification of segmented beam delivery using a commercial electronic portal imaging device
    • A. J. Curtin-Savard and E. B. Podgorsak, "Verification of segmented beam delivery using a commercial electronic portal imaging device," Med. Phys. 26, 737-742 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 737-742
    • Curtin-Savard, A.J.1    Podgorsak, E.B.2
  • 16
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity-modulated beam delivery by dynamic MLC technique
    • M. Partridge, P. M. Evans, A. Mosleh-Shirazi, and D. Convery, "Independent verification using portal imaging of intensity-modulated beam delivery by dynamic MLC technique," Med. Phys. 25, 1872-1879 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1872-1879
    • Partridge, M.1    Evans, P.M.2    Mosleh-Shirazi, A.3    Convery, D.4
  • 17
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • H. V. James, S. Atherton, G. J. Budgell, M. C. Kirby, and P. C. Williams, "Verification of dynamic multileaf collimation using an electronic portal imaging device," Phys. Med. Biol. 45, 495-509 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 495-509
    • James, H.V.1    Atherton, S.2    Budgell, G.J.3    Kirby, M.C.4    Williams, P.C.5
  • 18
    • 0030767978 scopus 로고    scopus 로고
    • Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system
    • L. Ma, O. B. Geise, and A. L. Boyer, "Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system," Med. Phys. 24, 1213-1219 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1213-1219
    • Ma, L.1    Geise, O.B.2    Boyer, A.L.3
  • 19
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • G. Kutcher et al., "Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40," Med. Phys. 21, 581-618 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 581-618
    • Kutcher, G.1
  • 21
    • 0034063644 scopus 로고    scopus 로고
    • Monitor unit calculation for intensity modulated photon field using a simple scatter-summation
    • L. Xing, Y. Chen, J. Li, G. Luxton, and A. Boyer, "Monitor unit calculation for intensity modulated photon field using a simple scatter-summation," Phys. Med. Biol. 45, N1-7 (2000).
    • (2000) Phys. Med. Biol. , vol.45
    • Xing, L.1    Chen, Y.2    Li, J.3    Luxton, G.4    Boyer, A.5
  • 22
    • 0031762329 scopus 로고    scopus 로고
    • Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
    • T. LoSasso, C. Chui, and C. C. Ling, "Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy," Med. Phys. 25, 1919-1927 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1919-1927
    • LoSasso, T.1    Chui, C.2    Ling, C.C.3
  • 26
    • 0029931223 scopus 로고    scopus 로고
    • Testing of dynamic multileaf collimation
    • C. Chui, S. V. Spirou, and T. LoSasso, "Testing of dynamic multileaf collimation," Med. Phys. 23, 635-641 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 635-641
    • Chui, C.1    Spirou, S.V.2    LoSasso, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.