메뉴 건너뛰기




Volumn 22, Issue 2, 2003, Pages 96-99

The single-piece milled titanium implant bridge

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; RESIN CEMENT; TITANIUM; ALLOY; BIOMEDICAL AND DENTAL MATERIALS; GOLD ALLOY; PROCERA;

EID: 0037313277     PISSN: 87502186     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (13)
  • 1
    • 0029377214 scopus 로고
    • Accuracy of implant supported prostheses in the edentulous jaw. Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three dimensional photogrammetric technique
    • Jemt T, Lie A. Accuracy of implant supported prostheses in the edentulous jaw. Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three dimensional photogrammetric technique. Clin Oral Implants Res. 1995;6:172-180.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 172-180
    • Jemt, T.1    Lie, A.2
  • 2
    • 0026214839 scopus 로고
    • Production of accurately fitting full-arch implant frameworks. Part I. Clinical procedures
    • Goll GE. Production of accurately fitting full-arch implant frameworks. Part I. Clinical procedures. J Prosthet Dent. 1991;66:377-384.
    • (1991) J Prosthet Dent , vol.66 , pp. 377-384
    • Goll, G.E.1
  • 3
    • 0027563662 scopus 로고
    • Full-arch implant framework casting accuracy. Preliminary in vitro observation for in vivo testing
    • Carr AB, Stewart RB. Full-arch implant framework casting accuracy. Preliminary in vitro observation for in vivo testing. J Prosthodont. 1992;2:2-8.
    • (1992) J Prosthodont , vol.2 , pp. 2-8
    • Carr, A.B.1    Stewart, R.B.2
  • 4
    • 0030277405 scopus 로고    scopus 로고
    • The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit
    • Carr AB, Gerard DA, Larsen PE, The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent. 1996;76:500-509.
    • (1996) J Prosthet Dent , vol.76 , pp. 500-509
    • Carr, A.B.1    Gerard, D.A.2    Larsen, P.E.3
  • 5
    • 0030237874 scopus 로고    scopus 로고
    • Prosthesis misfit and marginal bone loss in edentulous implant patients
    • Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants. 1996;11:620-625.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 620-625
    • Jemt, T.1    Book, K.2
  • 6
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent. 1997;78:596-604.
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 7
    • 0039415479 scopus 로고
    • London, England: Quintessence Publishing Co Ltd
    • White GE. Osseointegrated Dental Technology. London, England: Quintessence Publishing Co Ltd; 1993:61-94.
    • (1993) Osseointegrated Dental Technology , pp. 61-94
    • White, G.E.1
  • 8
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent. 1998;79:74-78.
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, T.D.1
  • 9
    • 84989001629 scopus 로고
    • Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants
    • Waskewicz GA, Ostrowski JS, Parks VJ. Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants. Int J Oral Maxillofac Implants. 1994;9:405-411.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 405-411
    • Waskewicz, G.A.1    Ostrowski, J.S.2    Parks, V.J.3
  • 10
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants. 1994;9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 11
    • 0027623331 scopus 로고
    • Three-dimensional analysis of the casting accuracy of one-piece osseointegrated implant-retained prostheses
    • Tan KB, Rubenstein JE, Nichollas JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece osseointegrated implant-retained prostheses. Int J Prosthodont. 1993;6:346-363.
    • (1993) Int J Prosthodont , vol.6 , pp. 346-363
    • Tan, K.B.1    Rubenstein, J.E.2    Nichollas, J.I.3    Yuodelis, R.A.4
  • 12
    • 0030226140 scopus 로고    scopus 로고
    • A Comparison of strains transferred to a bone stimulant between as-cast and post soldered implant frameworks for a five-implant-supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A. A Comparison of strains transferred to a bone stimulant between as-cast and post soldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont. 1996;5:193-200
    • (1996) J Prosthodont , vol.5 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 13
    • 0142140032 scopus 로고
    • JOMI Current Issues Forum: "How do you test a cast framework fit for a full-arch fixed implant-supported prosthesis?"
    • JOMI Current Issues Forum: "How do you test a cast framework fit for a full-arch fixed implant-supported prosthesis?" Int J Oral Maxillofac Implants. 1994;9:469-474.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 469-474


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.