메뉴 건너뛰기




Volumn 12, Issue 1, 2003, Pages 29-36

Design and microfabrication of a flexible oral electrotactile display

Author keywords

Electroplating; Electrotactile displays; Flexible devices; Sensory aids; Stimulator arrays

Indexed keywords

ELECTROPLATING; MICROMACHINING; POLYIMIDES; TACTILE READING AIDS; VIRTUAL REALITY;

EID: 0037302393     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2002.807478     Document Type: Article
Times cited : (18)

References (24)
  • 3
    • 0021423087 scopus 로고
    • Basic and applied research on tactile aids for deaf people: Progress and prospects
    • C. E. Sherrick, "Basic and applied research on tactile aids for deaf people: Progress and prospects," J. Acoust. Soc. Amer., vol. 75, pp. 1325-1342, 1984.
    • (1984) J. Acoust. Soc. Amer. , vol.75 , pp. 1325-1342
    • Sherrick, C.E.1
  • 6
    • 0035323956 scopus 로고    scopus 로고
    • A multilevel input system with force-sensitive elements
    • H. Tang, D. J. Beebe, and A. F. Kramer, "A multilevel input system with force-sensitive elements," Int. J. Human-Computer Studies, vol. 54, no. 4, pp. 495-507, 2001.
    • (2001) Int. J. Human-Computer Studies , vol.54 , Issue.4 , pp. 495-507
    • Tang, H.1    Beebe, D.J.2    Kramer, A.F.3
  • 10
    • 0014749675 scopus 로고
    • Tactile television-Mechanical and electrical image projection
    • C. C. Collins, "Tactile television-mechanical and electrical image projection," IEEE Trans. Man-Machine Syst., vol. MMS-11, pp. 58-70, 1970.
    • (1970) IEEE Trans. Man-Machine Syst. , vol.MMS-11 , pp. 58-70
    • Collins, C.C.1
  • 14
    • 0032440365 scopus 로고    scopus 로고
    • Form perception with a 49-point electrotactile stimulus array on the tongue: A technical note
    • P. Bach-y-Rita, K. A. Kaczmarek, M. E. Tyler, and J. Garcia-Lara, "Form perception with a 49-point electrotactile stimulus array on the tongue: A technical note," J. Rehab. Res. Dev., vol. 35, pp. 427-430, 1998.
    • (1998) J. Rehab. Res. Dev. , vol.35 , pp. 427-430
    • Bach-Y-Rita, P.1    Kaczmarek, K.A.2    Tyler, M.E.3    Garcia-Lara, J.4
  • 17
    • 0002027562 scopus 로고
    • Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation
    • W. R. Agnew and D. B. McCreery, Eds. Upper Saddle River, NJ: Prentice-Hall
    • L. S. Robblee and T. L. Rose, "Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation," in Neural Prosthesis: Fundamental Studies, W. R. Agnew and D. B. McCreery, Eds. Upper Saddle River, NJ: Prentice-Hall, 1990.
    • (1990) Neural Prosthesis: Fundamental Studies
    • Robblee, L.S.1    Rose, T.L.2
  • 18
    • 0020332065 scopus 로고
    • Analysis and control of the current distribution under circular dispersive electrodes
    • J. D. Wiley and J. G. Webster, "Analysis and control of the current distribution under circular dispersive electrodes," IEEE Trans. Biomed. Eng., vol. BME-29, pp. 381-389, 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.BME-29 , pp. 381-389
    • Wiley, J.D.1    Webster, J.G.2
  • 19
    • 0017621362 scopus 로고
    • Electrical stimulation with pt electrodes: I-A method for determination of 'real' electrode areas
    • S. B. Brummer and M. J. Turner, "Electrical stimulation with pt electrodes: I-a method for determination of 'real' electrode areas," IEEE Trans. Biomed. Eng., vol. BME-24, pp. 436-439, 1977.
    • (1977) IEEE Trans. Biomed. Eng. , vol.BME-24 , pp. 436-439
    • Brummer, S.B.1    Turner, M.J.2
  • 20
    • 0026890252 scopus 로고
    • A minimum profile uniform current density electrode
    • D. A. Ksienski, "A minimum profile uniform current density electrode," IEEE Trans. Biomed. Eng., vol. 39, pp. 682-692, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 682-692
    • Ksienski, D.A.1
  • 21
    • 0023526305 scopus 로고
    • Current density profiles of surface mounted and recessed electrodes for neural prostheses
    • J. T. Rubinstein, F. A. Spelman, M. Soma, and M. F. Suesserman, "Current density profiles of surface mounted and recessed electrodes for neural prostheses," IEEE Trans. Biomed. Eng., vol. BME-34, pp. 864-875, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 864-875
    • Rubinstein, J.T.1    Spelman, F.A.2    Soma, M.3    Suesserman, M.F.4
  • 22
    • 0027703631 scopus 로고
    • Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue
    • S. Schmidt, K. Horch, and R. Normann, "Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue," J. Biomed. Mater. Res., vol. 27, pp. 1393-1399, 1993.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 1393-1399
    • Schmidt, S.1    Horch, K.2    Normann, R.3
  • 24
    • 0027607944 scopus 로고
    • Metallic microstructures fabricated using photosensitive polyimide electroplating molds
    • June
    • A. B. Frazier and M. G. Allen, "Metallic microstructures fabricated using photosensitive polyimide electroplating molds," J. Microelectromech. Syst., vol. 2, pp. 87-94, June 1993.
    • (1993) J. Microelectromech. Syst. , vol.2 , pp. 87-94
    • Frazier, A.B.1    Allen, M.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.