메뉴 건너뛰기




Volumn 50 I, Issue 1, 2003, Pages 37-41

ROC analysis of ordered subset expectation maximization and filtered back projection technique for FDG-PET in lung cancer

Author keywords

Filtered back projection (FBP); Lung cancer; Ordered subset expectation maximization (OSEM); Positron emission tomography (PET); Receiver operating characteristic (ROC) curve

Indexed keywords

BACKPROPAGATION; IMAGE QUALITY; IMAGE RECONSTRUCTION; PULMONARY DISEASES; TUMORS;

EID: 0037291013     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2002.807878     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 0033738745 scopus 로고    scopus 로고
    • FDG imaging
    • R. E. Coleman, "FDG imaging," Nucl. Med. Biol., vol. 27, no. 7, pp. 689-690, 2000.
    • (2000) Nucl. Med. Biol. , vol.27 , Issue.7 , pp. 689-690
    • Coleman, R.E.1
  • 2
    • 0032921197 scopus 로고    scopus 로고
    • PET in lung cancer
    • May
    • _, "PET in lung cancer," J Nucl. Med., vol. 40, no. 5, pp. 814-820, May 1999.
    • (1999) J Nucl. Med. , vol.40 , Issue.5 , pp. 814-820
  • 3
    • 0034016999 scopus 로고    scopus 로고
    • Lung cancer and positron emission tomography with fluorodeoxyglucose
    • E. M. Marom, J. J. Erasmus, and E. F. Patz Jr, "Lung cancer and positron emission tomography with fluorodeoxyglucose," Lung Cancer, vol. 28, pp. 187-202, 2000.
    • (2000) Lung Cancer , vol.28 , pp. 187-202
    • Marom, E.M.1    Erasmus, J.J.2    Patz E.F., Jr.3
  • 5
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Apr.
    • K. Lange and R. Carson, "EM reconstruction algorithms for emission and transmission tomography," J Comput. Assist. Tomogr., vol. 8, no. 2, pp. 306-316, Apr. 1984.
    • (1984) J Comput. Assist. Tomogr. , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 7
    • 0026222685 scopus 로고
    • Performance evaluation of an iterative image reconstruction algorithm for positron emission tomography
    • Sept.
    • G. T. Heran and D. Odhner, "Performance evaluation of an iterative image reconstruction algorithm for positron emission tomography," IEEE Trans. Med. Imaging, vol. 10, pp. 336-346, Sept. 1991.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 336-346
    • Heran, G.T.1    Odhner, D.2
  • 8
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Dec.
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imaging, vol. 13, pp. 601-609, Dec. 1994.
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 9
    • 0030786648 scopus 로고    scopus 로고
    • A clinical perspective of accelerated statistical reconstruction
    • July
    • B. F. Hutton, H. M. Hudson, and F. J. Beeckman, "A clinical perspective of accelerated statistical reconstruction," Eur. J. Nucl. Med., vol. 24, no. 7, pp, 797-808, July 1997.
    • (1997) Eur. J. Nucl. Med. , vol.24 , Issue.7 , pp. 797-808
    • Hutton, B.F.1    Hudson, H.M.2    Beeckman, F.J.3
  • 10
    • 0027213289 scopus 로고
    • Results of a clinical receiver operating characteristic study comparing filtered back projection and maximum likelihood estimator images in FDG PET studies
    • Dec.
    • J. Llacer et al., "Results of a clinical receiver operating characteristic study comparing filtered back projection and maximum likelihood estimator images in FDG PET studies," J. Nucl. Med., vol. 34, no. 7, pp. 1198-1203, Dec. 1993.
    • (1993) J. Nucl. Med. , vol.34 , Issue.7 , pp. 1198-1203
    • Llacer, J.1
  • 11
    • 0033376809 scopus 로고    scopus 로고
    • ROC and localization ROC analyzes of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm
    • Dec.
    • T. H. Farquhar et al., "ROC and localization ROC analyzes of lesion detection in whole-body FDG PET: Effects of acquisition mode, attenuation correction and reconstruction algorithm," J Nucl Med, vol. 40, no. 12, pp. 2043-2052, Dec. 1999.
    • (1999) J Nucl Med , vol.40 , Issue.12 , pp. 2043-2052
    • Farquhar, T.H.1
  • 12
    • 0033061341 scopus 로고    scopus 로고
    • Attenuation correction in whole-body FDG oncological studies: The role of statistical reconstruction
    • June
    • M. Lonneux et al., "Attenuation correction in whole-body FDG oncological studies: The role of statistical reconstruction," Eur. J. Nucl. Med., vol. 26, no. 6, pp. 591-598, June 1999.
    • (1999) Eur. J. Nucl. Med. , vol.26 , Issue.6 , pp. 591-598
    • Lonneux, M.1
  • 13
    • 0030978277 scopus 로고    scopus 로고
    • Bayesian image reconstruction for emission tomography based on median root prior
    • Mar.
    • S. Alenius and U. Ruotsalainen, "Bayesian image reconstruction for emission tomography based on median root prior," Eur. J. Nucl. Med., vol. 24, no. 3, pp. 258-265, Mar. 1997.
    • (1997) Eur. J. Nucl. Med. , vol.24 , Issue.3 , pp. 258-265
    • Alenius, S.1    Ruotsalainen, U.2
  • 14
    • 0035297601 scopus 로고    scopus 로고
    • Fast EM-like methods for maximum "A posteriori" estimates in emission tomography
    • Apr.
    • A. R. De Pierro and M. E. B. Yamagishi, "Fast EM-like methods for maximum "A posteriori" estimates in emission tomography," IEEE Trans. Med. Imaging, vol. 20, pp. 280-288, Apr. 2001.
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 280-288
    • De Pierro, A.R.1    Yamagishi, M.E.B.2
  • 15
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction in positron emission tomography
    • L. Shepp and Y. Vardi, "Maximum likelihood reconstruction in positron emission tomography," IEEE Trans. Med. Imaging, vol. MI-1, pp. 113-122, 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.1    Vardi, Y.2
  • 16
    • 0027246463 scopus 로고
    • Iterative reconstruction methods for nonuniform attenuation distribution in SPECT
    • July
    • A. Maze, J. Le Cloirec, R. Collorec, Y. Bizais, P. Briandet, and P. Bourguet, "Iterative reconstruction methods for nonuniform attenuation distribution in SPECT," J. Nucl. Med., vol. 34, no. 7, pp. 1204-1209, July 1993.
    • (1993) J. Nucl. Med. , vol.34 , Issue.7 , pp. 1204-1209
    • Maze, A.1    Le Cloirec, J.2    Collorec, R.3    Bizais, Y.4    Briandet, P.5    Bourguet, P.6
  • 17
    • 0033386225 scopus 로고    scopus 로고
    • Maximum-likelihood reconstruction with ordered subsets in bone SPECT
    • Dec.
    • D. Blocklet, A. Seret, N. Popa, and A. Schoutens, "Maximum-likelihood reconstruction with ordered subsets in bone SPECT," J. Nucl. Med., vol. 40, no. 12, pp. 1978-1984, Dec. 1999.
    • (1999) J. Nucl. Med. , vol.40 , Issue.12 , pp. 1978-1984
    • Blocklet, D.1    Seret, A.2    Popa, N.3    Schoutens, A.4
  • 18
    • 0031894247 scopus 로고    scopus 로고
    • Median root prior and ordered subsets in Bayesian image reconstruction of single-photon emission tomography
    • Mar.
    • A. Seret, "Median root prior and ordered subsets in Bayesian image reconstruction of single-photon emission tomography," Eur. J. Nucl. Med., vol. 25, no. 3, pp. 215-219, Mar. 1998.
    • (1998) Eur. J. Nucl. Med. , vol.25 , Issue.3 , pp. 215-219
    • Seret, A.1
  • 19
    • 0031951077 scopus 로고    scopus 로고
    • Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography
    • Jan.
    • C. Kamphuis, F. J. Beekman, P. P. van Rijk, and M. A. Viergever, "Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography," Eur. J. Nucl. Med., vol. 25, no. 1, pp. 8-18, Jan. 1998.
    • (1998) Eur. J. Nucl. Med. , vol.25 , Issue.1 , pp. 8-18
    • Kamphuis, C.1    Beekman, F.J.2    Van Rijk, P.P.3    Viergever, M.A.4
  • 20
    • 0033975686 scopus 로고    scopus 로고
    • Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: A phantom study
    • Feb.
    • C. Vanhove, M. Defrise, P. R. Franken, H. Everaert, F. Deconinck, and A. Bossuyt, "Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: A phantom study," Eur. J. Nucl. Med., vol. 27, no. 2, pp. 140-146, Feb. 2000.
    • (2000) Eur. J. Nucl. Med. , vol.27 , Issue.2 , pp. 140-146
    • Vanhove, C.1    Defrise, M.2    Franken, P.R.3    Everaert, H.4    Deconinck, F.5    Bossuyt, A.6
  • 21
    • 0030865170 scopus 로고    scopus 로고
    • Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images
    • Sept.
    • F. M. Bengel, S. I. Ziegler, N. Avril, W. Weber, C. Laubenbacher, and M. Schwaiger, "Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images," Eur. J. Nucl. Med., vol. 24, no. 9, pp. 1091-1098, Sept. 1997.
    • (1997) Eur. J. Nucl. Med. , vol.24 , Issue.9 , pp. 1091-1098
    • Bengel, F.M.1    Ziegler, S.I.2    Avril, N.3    Weber, W.4    Laubenbacher, C.5    Schwaiger, M.6
  • 22
    • 0033024059 scopus 로고    scopus 로고
    • Role of attenuation correction for fluorine-18 fluorodeoxyglucose positron emission tomography in the primary staging of malignant lymphoma
    • Jan.
    • J. Kotzerke, A. Guhlmann, F. Moog, N. Frickhofen, and S. N. Reske, "Role of attenuation correction for fluorine-18 fluorodeoxyglucose positron emission tomography in the primary staging of malignant lymphoma," Eur. J. Nucl. Med., vol. 26, no. 1, pp. 31-38, Jan. 1999.
    • (1999) Eur. J. Nucl. Med. , vol.26 , Issue.1 , pp. 31-38
    • Kotzerke, J.1    Guhlmann, A.2    Moog, F.3    Frickhofen, N.4    Reske, S.N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.