메뉴 건너뛰기




Volumn 40, Issue 12, 1999, Pages 1978-1984

Maximum-likelihood reconstruction with ordered subsets in bone SPECT

Author keywords

Bone SPECT; Filtered backprojection; Iterative reconstruction; Maximum likelihood of expectation maximization; Ordered subset expectation maximum

Indexed keywords

ARTICLE; ARTIFACT; BONE SCINTISCANNING; DIAGNOSTIC IMAGING; HUMAN; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; THORACOLUMBAR SPINE;

EID: 0033386225     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (30)

References (18)
  • 3
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr. 1984;8:306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 6
    • 0030786648 scopus 로고    scopus 로고
    • A clinical perspective of accelerated statistical reconstruction
    • Hutton BF, Hudson HM, Beeckman FJ. A clinical perspective of accelerated statistical reconstruction. Eur J Nucl Med. 1997;24:797-808.
    • (1997) Eur J Nucl Med , vol.24 , pp. 797-808
    • Hutton, B.F.1    Hudson, H.M.2    Beeckman, F.J.3
  • 7
    • 0025005768 scopus 로고
    • Evaluation of techniques for the elimination of "hot" bladder artifacts in SPECT of the pelvis
    • O'Connor MK, Kelly BJ. Evaluation of techniques for the elimination of "hot" bladder artifacts in SPECT of the pelvis. J Nucl Med 1990;31:1872-1875.
    • (1990) J Nucl Med , vol.31 , pp. 1872-1875
    • O'Connor, M.K.1    Kelly, B.J.2
  • 8
    • 0025910240 scopus 로고
    • An investigation of the magnitude and causes of count loss artifacts in SPECT imaging
    • Gillen GJ, Gilmore B, Elliot AT. An investigation of the magnitude and causes of count loss artifacts in SPECT imaging. J Nucl Med. 1991;32:1771-1776.
    • (1991) J Nucl Med , vol.32 , pp. 1771-1776
    • Gillen, G.J.1    Gilmore, B.2    Elliot, A.T.3
  • 9
    • 0030978277 scopus 로고    scopus 로고
    • Bayesian image reconstruction for emission tomography based on median root prior
    • Alenius S, Ruotsalainen U. Bayesian image reconstruction for emission tomography based on median root prior. Eur J Nucl Med. 1996;24:258-265.
    • (1996) Eur J Nucl Med , vol.24 , pp. 258-265
    • Alenius, S.1    Ruotsalainen, U.2
  • 10
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging. 1982;1:113-122.
    • (1982) IEEE Trans Med Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 11
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601-609.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 12
    • 0031894247 scopus 로고    scopus 로고
    • Median root prior and ordered subsets in Bayesian image reconstruction of single photon emission tomography
    • Seret A. Median root prior and ordered subsets in Bayesian image reconstruction of single photon emission tomography. Eur J Nucl Med. 1998;25:215-219.
    • (1998) Eur J Nucl Med , vol.25 , pp. 215-219
    • Seret, A.1
  • 13
    • 0025404969 scopus 로고
    • Bayesian reconstructions from emission tomography data using a modified EM algorithm
    • Green PJ. Bayesian reconstructions from emission tomography data using a modified EM algorithm. IEEE Trans Med Imaging. 1990;9:84-93.
    • (1990) IEEE Trans Med Imaging , vol.9 , pp. 84-93
    • Green, P.J.1
  • 15
    • 0343183519 scopus 로고    scopus 로고
    • How critical is subset balance for OSEM reconstruction in myocardial SPECT ?
    • Hutton BF, Lau YH. How critical is subset balance for OSEM reconstruction in myocardial SPECT [abstract]? J Nucl Med. 1997;385:57P.
    • (1997) J Nucl Med , vol.385
    • Hutton, B.F.1    Lau, Y.H.2
  • 18
    • 0342314027 scopus 로고    scopus 로고
    • Scintimammography with sestamibi for detection of breast carcinoma: Diagnostic accuracy of planar, SPECT and combined data evaluation
    • Tiling R, Linke R, Sommer H, et al. Scintimammography with sestamibi for detection of breast carcinoma: diagnostic accuracy of planar, SPECT and combined data evaluation [abstract]. Eur J Nucl Med. 1997;24:916.
    • (1997) Eur J Nucl Med , vol.24 , pp. 916
    • Tiling, R.1    Linke, R.2    Sommer, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.