Volumn 26, Issue 1 II, 2003, Pages 244-247

Impact of adaptive rate pacing controlled by a right ventricular impedance sensor on cardiac output in response to exercise

Author keywords

Adaptive rate pacing; Cardiac output; Exercise; Right ventricular impedance

Indexed keywords

ADAPTATION; AGE; AGED; ARTIFICIAL HEART PACEMAKER; CARDIOGRAPHY; CLINICAL ARTICLE; CONFERENCE PAPER; EXERCISE; FEMALE; HEART OUTPUT; HEART PACING; HEART RATE; HEART RIGHT VENTRICLE; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; IMPEDANCE; MALE; OXYGEN CONSUMPTION; PULSE GENERATOR; RELIABILITY; SENSOR; SPIROMETRY; SYMPTOMATOLOGY;

EID: 0037253145     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.00025.x     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 3
    • 0033782999 scopus 로고    scopus 로고
    • Closed-loop stimulation using intracardiac impedance as a sensor principle: Correlation of right ventricular dP/dt max and intracardiac impedance during dobutamine stress test
    • Oswald S, Cron T, Gradel C, et al. Closed-loop stimulation using intracardiac impedance as a sensor principle: Correlation of right ventricular dP/dt max and intracardiac impedance during dobutamine stress test. PACE 2000; 23:1502-1508.
    • (2000) PACE , vol.23 , pp. 1502-1508
    • Oswald, S.1    Cron, T.2    Gradel, C.3
  • 4
    • 0031753464 scopus 로고    scopus 로고
    • Interindividual comparison of different sensor principles for rate adaptive pacing
    • Malinowski K. Interindividual comparison of different sensor principles for rate adaptive pacing. PACE 1998; 21:2209-2213.
    • (1998) PACE , vol.21 , pp. 2209-2213
    • Malinowski, K.1
  • 6
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance. Theory and rationale
    • Bernstein DP. A new stroke volume equation for thoracic electrical bioimpedance. Theory and rationale. Crit Care Med 1986; 14:904-909.
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 8
    • 0031667337 scopus 로고    scopus 로고
    • Effects of sensor selection on exercise stroke volume in pacemaker dependent patients
    • Haennel R, Logan T, Dunne C, et al. Effects of sensor selection on exercise stroke volume in pacemaker dependent patients. PACE 1998; 21:1700-1708.
    • (1998) PACE , vol.21 , pp. 1700-1708
    • Haennel, R.1    Logan, T.2    Dunne, C.3
  • 9
    • 0024443908 scopus 로고
    • Rate-modulated cardiac pacing based on transthoracic measurements of minute ventilation correlation with exercise gas exchange
    • Kay GN, Bubien RS, Epstein AE, et al. Rate-modulated cardiac pacing based on transthoracic measurements of minute ventilation correlation with exercise gas exchange. J Am Coll Cardiol 1989; 14:1283-1289.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 1283-1289
    • Kay, G.N.1    Bubien, R.S.2    Epstein, A.E.3
  • 10
    • 0024425609 scopus 로고
    • A comparative evaluation of minute ventilation sensing and activity sensing adaptive-rate pacemakers during daily activities
    • Lau CP, Wong CK, Leung WH, et al. A comparative evaluation of minute ventilation sensing and activity sensing adaptive-rate pacemakers during daily activities. PACE 1989; 12:1514-1521.
    • (1989) PACE , vol.12 , pp. 1514-1521
    • Lau, C.P.1    Wong, C.K.2    Leung, W.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.