메뉴 건너뛰기




Volumn 47, Issue 2, 2002, Pages 239-256

Dosimetry characteristics of degraded electron beams investigated by Monte Carlo calculations in a setup for intraoperative radiation therapy

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; ELECTRON BEAMS; ELECTRON SCATTERING; IONIZATION CHAMBERS; MONTE CARLO METHODS; SPECTRUM ANALYSIS;

EID: 0037148096     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/47/2/305     Document Type: Article
Times cited : (23)

References (49)
  • 1
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • American Association of Physicists in Medicine (AAPM) Task Group 21
    • (1983) Med. Phys. , vol.10 , pp. 741-771
  • 2
    • 0025975407 scopus 로고
    • Clinical electron-beam dosimetry
    • American Association of Physicists in Medicine (AAPM) Task Group 25
    • (1991) Med. Phys. , vol.18 , pp. 73-109
  • 11
    • 0008021448 scopus 로고
    • Electron energy and angular distributions in radiotherapy
    • Thesis University of Kentucky
    • (1992)
    • Deasy, J.O.1
  • 14
    • 0004297164 scopus 로고
    • ITS: The integrated TIGER series of coupled electron/photon Monte Carlo transport codes
    • Sandia National Laboratories Report SAND84-0573 (Albuquerque and Livermore: Sandia National Laboratories)
    • (1984)
    • Halbleib, J.A.1    Mehlhorn, T.A.2
  • 16
    • 0003484991 scopus 로고
    • Absorbed dose determination in photon and electron beams: An international code of practice
    • International Atomic Energy Agency (IAEA) Technical Reports Series No. 277 (Vienna: IAEA)
    • (1987)
  • 17
    • 0003680969 scopus 로고    scopus 로고
    • The use of plane parallel ionization chambers in high energy electron and photon beams: An international code of practice for dosimetry
    • International Atomic Energy Agency (IAEA) Technical Reports Series No. 381 (Vienna: IAEA)
    • (1997)
  • 18
    • 0003639048 scopus 로고
    • Radiation dosimetry: Electron beams with energies between 1 and 50
    • International Commission on Radiation Units and Measurements (ICRU) MeV ICRU Report 35 (Bethesda, MD: ICRU)
    • (1984)
  • 19
    • 0003982205 scopus 로고
    • Stopping powers for electrons and positrons
    • International Commission on Radiation Units and Measurements (ICRU) ICRU Report 37 (Bethesda, MD: ICRU)
    • (1984)
  • 20
    • 0003438221 scopus 로고
    • Use of computers in external beam radiotherapy procedures with high-energy photons and electrons
    • International Commission on Radiation Units and Measurements (ICRU) ICRU Report 42 (Bethesda, MD: ICRU)
    • (1987)
  • 26
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 27
    • 0003797114 scopus 로고    scopus 로고
    • The EGSnrc code system: Monte Carlo simulation of electron and photon transport
    • National Research Council of Canada Report PIRS-701 (Ottawa: NRC)
    • (2000)
    • Kawrakow, I.1    Rogers, D.W.O.2
  • 28
    • 0028240949 scopus 로고
    • An algorithm to include the bremsstrahlung contamination in the determination of the absorbed dose in electron beams
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1103-1112
    • Klevenhagen, S.C.1
  • 29
    • 0033406033 scopus 로고    scopus 로고
    • Finding mechanisms responsible for the spectral distribution of electron beams produced by a linear accelerator
    • (1999) Med. Phys. , vol.26 , pp. 2589-2596
    • Kok, J.G.M.1    Welleweerd, J.2
  • 33
    • 0003903581 scopus 로고    scopus 로고
    • BEAMDP as a general-purpose utility
    • National Research Council of Canada Report PIRS-0509e (Ottawa: NRC)
    • (1998)
    • Ma, C.-M.1    Rogers, D.W.O.2
  • 35
    • 0032936611 scopus 로고    scopus 로고
    • An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams
    • (1999) Med. Phys. , vol.26 , pp. 839-844
    • Mobit, P.N.1    Sandison, G.A.2
  • 39
    • 0343851590 scopus 로고    scopus 로고
    • IORT apparatus design improvement through the evaluation of electron spectral distributions using Monte Carlo methods
    • (2000) Med. Phys. , vol.27 , pp. 215-220
    • Price, R.A.1    Ayyangar, K.M.2
  • 44
    • 0023766472 scopus 로고
    • A Monte Carlo investigation of surface doses for broad electron beams
    • (1988) Phys. Med. Biol. , vol.33 , pp. 939-953
    • Udale, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.