메뉴 건너뛰기




Volumn 97, Issue 10, 2002, Pages 595-600

Evaluation of significant coronary artery stenosis by magnetic resonance flow measurement and correlation of the intracoronary to the aortic flow;Kernspintomographische flussquantifizierung in koronargefȧßen zur evaluierung hochgradiger koronarstenosen: Korrelation des mittleren intrakoronaren blutflusses zum aortenfluss

Author keywords

Coronary artery stenoses; Flow quantification; MR flowmetry; MR imaging

Indexed keywords

ACCURACY; ADULT; AGED; AORTA FLOW; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; DISEASE SEVERITY; EVALUATION; FEMALE; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; ANGIOCARDIOGRAPHY; BLOOD FLOW VELOCITY; METHODOLOGY; MIDDLE AGED; PHYSIOLOGY; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY;

EID: 0037107330     PISSN: 07235003     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00063-002-1200-6     Document Type: Article
Times cited : (3)

References (19)
  • 1
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • Bomar RM, Stuber M, Danias PG, et al. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 1999;99:3139-48.
    • (1999) Circulation , vol.99 , pp. 3139-3148
    • Bomar, R.M.1    Stuber, M.2    Danias, P.G.3
  • 2
    • 0030226419 scopus 로고    scopus 로고
    • Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy of the number ofcine frames
    • Clarke G, Hundley WG, McColl RW, et al. Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy of the number ofcine frames. J Magn Reson Imaging 1996;6:733-42.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 733-742
    • Clarke, G.1    Hundley, W.G.2    McColl, R.W.3
  • 3
    • 0027602979 scopus 로고
    • MR characterization of blood flow in native and grafted internal mammary arteries
    • Debatin JF, Strong JA, Sostman HD, et al. MR characterization of blood flow in native and grafted internal mammary arteries. J Magn Reson Imaging 1993;3:443-50.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 443-450
    • Debatin, J.F.1    Strong, J.A.2    Sostman, H.D.3
  • 4
    • 0027665781 scopus 로고
    • Flow velocity quantification in human coronary arteries with fast, breath-hold MR angiography
    • Edelmann RR, Manning WJ, Gervino E, et al. Flow velocity quantification in human coronary arteries with fast, breath-hold MR angiography. J Magn Reson Imaging 1993;3:699-703.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 699-703
    • Edelmann, R.R.1    Manning, W.J.2    Gervino, E.3
  • 6
    • 0028953895 scopus 로고
    • Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques
    • Foo TKF, Bernstein MA, Asien AM, et al. Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques. Radiology 1995;195:471-8.
    • (1995) Radiology , vol.195 , pp. 471-478
    • Foo, T.K.F.1    Bernstein, M.A.2    Asien, A.M.3
  • 7
    • 0030049876 scopus 로고    scopus 로고
    • Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study
    • Galjee MA, Rossum AC van, Doesburg T, et al. Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. Circulation 1996;93:660-6.
    • (1996) Circulation , vol.93 , pp. 660-666
    • Galjee, M.A.1    Van Rossum, A.C.2    Doesburg, T.3
  • 8
    • 0028954036 scopus 로고
    • Noninvasive evaluation of aorto-coronary bypass grafts with magnetic resonance flow mapping
    • Hoogendorn LI, Pattyanama PMT, Buis B, et al. Noninvasive evaluation of aorto-coronary bypass grafts with magnetic resonance flow mapping. Am J Cardiol 1995;75:845-8.
    • (1995) Am J Cardiol , vol.75 , pp. 845-848
    • Hoogendorn, L.I.1    Pattyanama, P.M.T.2    Buis, B.3
  • 9
    • 0032966265 scopus 로고    scopus 로고
    • Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses
    • Huber A, Nikolaou K, Gonschior P, Knez, A et al. Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses. AJR Am J Roentgenol 1999;173:95-101.
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 95-101
    • Huber, A.1    Nikolaou, K.2    Gonschior, P.3    Knez, A.4
  • 10
    • 0028223372 scopus 로고
    • The application of breath-hold phase velocity mapping techniques to the measurements of coronary artery blood flow velocity: Phantom data and initial in vivo results
    • Keegan J, Finnin D, Gatehouse P, et al. The application of breath-hold phase velocity mapping techniques to the measurements of coronary artery blood flow velocity: Phantom data and initial in vivo results. Magn Reson Med 1994;31:526-36.
    • (1994) Magn Reson Med , vol.31 , pp. 526-536
    • Keegan, J.1    Finnin, D.2    Gatehouse, P.3
  • 11
    • 0032900232 scopus 로고    scopus 로고
    • Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - Initial experience
    • Kessler W, Laub G, Achenbach S, et al. Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging - initial experience. Radiology 1999;210:566-72.
    • (1999) Radiology , vol.210 , pp. 566-572
    • Kessler, W.1    Laub, G.2    Achenbach, S.3
  • 12
    • 0034137277 scopus 로고    scopus 로고
    • Flussquantifizierung in koronar- und bypassgefȧßen der MR-phasenkontrasttechnik
    • Kreitner KF, Voigländer T, Wittlinger T, et al. Flussquantifizierung in koronar- und bypassgefȧßen der MR-phasenkontrasttechnik. Radiologe 2000;40:143-9.
    • (2000) Radiologe , vol.40 , pp. 143-149
    • Kreitner, K.F.1    Voigländer, T.2    Wittlinger, T.3
  • 13
    • 0344673385 scopus 로고    scopus 로고
    • Flow profiles in the left anterior descending and right coronary artery assessed by MR velocity quantification: Effects of through-plane and in-plane motion of the heart
    • Marcus JT, Smenk HG, Kuijer JP, et al. Flow profiles in the left anterior descending and right coronary artery assessed by MR velocity quantification: Effects of through-plane and in-plane motion of the heart. J Comput Assist Tomogr 1999;23:567-76.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 567-576
    • Marcus, J.T.1    Smenk, H.G.2    Kuijer, J.P.3
  • 14
    • 0030024521 scopus 로고    scopus 로고
    • Coronary flow reserve: Non-invasive measurements in humans with breath-hold velocity-encoded cine MR imaging
    • Sakuma H, Blake LM, Amidon TM, et al. Coronary flow reserve: Non-invasive measurements in humans with breath-hold velocity-encoded cine MR imaging. Radiology 1996;198:745-50.
    • (1996) Radiology , vol.198 , pp. 745-750
    • Sakuma, H.1    Blake, L.M.2    Amidon, T.M.3
  • 15
    • 0029680146 scopus 로고    scopus 로고
    • Breathhold MR Measurements of blood flow velocity in internal mammary arteries and coronary artery bypass grafts
    • Sakuma H, Globits S, O'Sullivan A, et al. Breathhold MR Measurements of blood flow velocity in internal mammary arteries and coronary artery bypass grafts. J Magn Reson Imaging 1996;6:219-22.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 219-222
    • Sakuma, H.1    Globits, S.2    O'Sullivan, A.3
  • 16
    • 0032907360 scopus 로고    scopus 로고
    • Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary augiography
    • Sandstede JJW, Pabst T, Beer M, et al. Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary augiography. AJR Am J Roentgenol 1998; 172:135-9.
    • (1998) AJR Am J Roentgenol , vol.172 , pp. 135-139
    • Sandstede, J.J.W.1    Pabst, T.2    Beer, M.3
  • 17
    • 0031660282 scopus 로고    scopus 로고
    • Breath-hold coronary MR angiography with volume targed imaging
    • Wielopolski PA, Geuns RJM, de Feyter PJ, et al. Breath-hold coronary MR angiography with volume targed imaging. Radiology 1998;209:209-19.
    • (1998) Radiology , vol.209 , pp. 209-219
    • Wielopolski, P.A.1    Geuns, R.J.M.2    De Feyter, P.J.3
  • 18
    • 0031307299 scopus 로고    scopus 로고
    • Kontrastmittelverstärkte magnetresonanzangiographie zur überprüfung der durchgängigkeit koronarer bypässe
    • Wintersberger BJ, von Smekal A, Engelmaun MG, et al. Kontrastmittelverstärkte magnetresonanzangiographie zur überprüfung der durchgängigkeit koronarer bypässe. Fortschr Röntgenstr 1997; 167:572-8.
    • (1997) Fortschr Röntgenstr , vol.167 , pp. 572-578
    • Wintersberger, B.J.1    Von Smekal, A.2    Engelmaun, M.G.3
  • 19
    • 0023796771 scopus 로고
    • Current complication of diagnostics and therapeutics cardiac catheterization
    • Wymann RM, Safian RD, Portway V, et al. Current complication of diagnostics and therapeutics cardiac catheterization. J Am Coll Cardiol 1988;12:1400-6.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1400-1406
    • Wymann, R.M.1    Safian, R.D.2    Portway, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.