-
2
-
-
0030388567
-
Cooling of electronics by heat pipes and thermosyphons-A review of methods and possibilities
-
HTD-Vol. 329
-
B. Palm and N. Tengblad, "Cooling of electronics by heat pipes and thermosyphons-A review of methods and possibilities," in Proc. Nat. Heat Transfer Conf., vol. 7, 1996, HTD-Vol. 329, pp. 97-108.
-
(1996)
Proc. Nat. Heat Transfer Conf.
, vol.7
, pp. 97-108
-
-
Palm, B.1
Tengblad, N.2
-
3
-
-
0030102061
-
External two-phase thermosyphons for cooling of electronic components
-
N. Tengblad and B. Palm, "External two-phase thermosyphons for cooling of electronic components," Int. J. Microcircuits Electron. Packag., pp. 22-29, 1996.
-
(1996)
Int. J. Microcircuits Electron. Packag.
, pp. 22-29
-
-
Tengblad, N.1
Palm, B.2
-
4
-
-
0021583185
-
Heat sink studs having enhanced boiling surfaces for cooling microelectronic components
-
Paper 84-WA/HT-89
-
W. Nakayama, T. Nakajima, and S. Hirawasa, "Heat sink studs having enhanced boiling surfaces for cooling microelectronic components," in ASME, 1984, Paper 84-WA/HT-89.
-
(1984)
ASME
-
-
Nakayama, W.1
Nakajima, T.2
Hirawasa, S.3
-
5
-
-
0027556749
-
Optimization of enhanced surfaces for high flux chip cooling by pool boiling
-
I. Mudawar and T. M. Anderson, "Optimization of enhanced surfaces for high flux chip cooling by pool boiling," ASME J. Electron. Packag., vol. 115, pp. 89-100, 1993.
-
(1993)
ASME J. Electron. Packag.
, vol.115
, pp. 89-100
-
-
Mudawar, I.1
Anderson, T.M.2
-
6
-
-
0001135231
-
Performance of a compact two-phase thermosyphon: Effect of evaporator inclination, liquid fill volume and contact resistance
-
Kyongju, Korea
-
C. Ramaswamy, Y. Joshi, W. Nakayama, and W. B. Johnson, "Performance of a compact two-phase thermosyphon: Effect of evaporator inclination, liquid fill volume and contact resistance," in Proc. 11th Int. Heat Transfer Conf, vol. 2, Kyongju, Korea, 1998, pp. 127-132.
-
(1998)
Proc. 11th Int. Heat Transfer Conf
, vol.2
, pp. 127-132
-
-
Ramaswamy, C.1
Joshi, Y.2
Nakayama, W.3
Johnson, W.B.4
-
7
-
-
0032673847
-
Thermal performance of a compact two-phase thermosyphon: Response to evaporator confinement and transient loads
-
_, "Thermal performance of a compact two-phase thermosyphon: Response to evaporator confinement and transient loads," J. Enhanced Heat Transfer, vol. 6, pp. 279-288, 1999.
-
(1999)
J. Enhanced Heat Transfer
, vol.6
, pp. 279-288
-
-
-
8
-
-
0033907396
-
Combined effects of sub-cooling and operating pressure on the performance of a two-chamber thermosyphon
-
Mar.
-
_, "Combined effects of sub-cooling and operating pressure on the performance of a two-chamber thermosyphon," IEEE Trans. Comp. Packag. Technol., vol. 23, pp. 61-69, Mar. 2000.
-
(2000)
IEEE Trans. Comp. Packag. Technol.
, vol.23
, pp. 61-69
-
-
-
11
-
-
0013411065
-
Effect of condenser location and tubing length on the performance of a compact two-phase thermosyphon
-
New York, NY, Nov. 11-16
-
L. Yuan, Y. Joshi, and W. Nakayama, "Effect of condenser location and tubing length on the performance of a compact two-phase thermosyphon," in Proc. 2001 Int. Mech. Eng. Congress Expo., New York, NY, Nov. 11-16, 2001.
-
(2001)
Proc. 2001 Int. Mech. Eng. Congress Expo.
-
-
Yuan, L.1
Joshi, Y.2
Nakayama, W.3
|