메뉴 건너뛰기




Volumn 9, Issue 6, 2002, Pages 964-971

A method for detecting the transition from corona from water droplets to dry-band arcing on silicone rubber insulators

Author keywords

[No Author keywords available]

Indexed keywords

CURRENT DENSITY; LEAKAGE CURRENTS; PARTIAL DISCHARGES; SILICON COMPOUNDS;

EID: 0036990860     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2002.1115491     Document Type: Article
Times cited : (40)

References (24)
  • 1
    • 0033316787 scopus 로고    scopus 로고
    • Outdoor high voltage composite polymeric insulators
    • R. Hackam, "Outdoor High Voltage Composite Polymeric Insulators", IEEE Trans. DEI, Vol. 6, pp. 557-585, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 557-585
    • Hackam, R.1
  • 2
    • 0029373268 scopus 로고
    • Swedish research on the application of composite insulators in outdoor insulation
    • S. Gubanski and R. Hartings, "Swedish Research on the Application of Composite Insulators in Outdoor Insulation", IEEE Electrical Insulation Magazine, Vol. 11, No. 5, pp. 24-31, 1995.
    • (1995) IEEE Electrical Insulation Magazine , vol.11 , Issue.5 , pp. 24-31
    • Gubanski, S.1    Hartings, R.2
  • 3
    • 0033340674 scopus 로고    scopus 로고
    • RTV silicone rubber coatings for outdoor insulators
    • E. A. Cherney and R. S. Gorur, "RTV Silicone Rubber Coatings for Outdoor Insulators", IEEE Trans. DEI, Vol. 6, pp. 605-611, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 605-611
    • Cherney, E.A.1    Gorur, R.S.2
  • 4
    • 33747438222 scopus 로고
    • The loss and recovery of hydrophobicity of RTV silicone rubber insulator coatings
    • S. H. Kim, E. A. Cherney and R. Hackam, "The Loss and Recovery of Hydrophobicity of RTV Silicone Rubber Insulator Coatings", IEEE Trans. Power Delivery, Vol. 5, pp. 1491-1500, 1990.
    • (1990) IEEE Trans. Power Delivery , vol.5 , pp. 1491-1500
    • Kim, S.H.1    Cherney, E.A.2    Hackam, R.3
  • 5
    • 0026238514 scopus 로고
    • Suppression mechanism of leakage current on RTV coated porcelain and silicone rubber insulators
    • S. H. Kim, E. A. Cherney and R. Hackam, "Suppression Mechanism of Leakage Current on RTV Coated Porcelain and Silicone Rubber Insulators", IEEE Trans. Power Delivery, Vol. 6, pp. 1549-1556, 1991.
    • (1991) IEEE Trans. Power Delivery , vol.6 , pp. 1549-1556
    • Kim, S.H.1    Cherney, E.A.2    Hackam, R.3
  • 6
    • 0000440857 scopus 로고    scopus 로고
    • Modern outdoor electrical insulation
    • S. M. Gubanski, "Modern Outdoor Electrical Insulation", IEEE Trans. DEI, Vol. 6, pp. 517-518, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 517-518
    • Gubanski, S.M.1
  • 7
    • 0033353513 scopus 로고    scopus 로고
    • Leakage currents on non-ceramic insulators and materials
    • M. A. R. M. Fernando and S. M. Gubanski, "Leakage Currents on Non-ceramic Insulators and Materials", IEEE Trans. DEI, Vol. 6, pp. 660-667, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 660-667
    • Fernando, M.A.R.M.1    Gubanski, S.M.2
  • 8
    • 0033339040 scopus 로고    scopus 로고
    • Leakage currents patterns on contaminated polymeric surfaces
    • M. A. R. M. Fernando and S. M. Gubanski, "Leakage Currents Patterns on Contaminated Polymeric Surfaces", IEEE Trans. DEI, Vol. 6, pp. 688-694, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 688-694
    • Fernando, M.A.R.M.1    Gubanski, S.M.2
  • 10
    • 0013275224 scopus 로고
    • Surface and ageing phenomena on organic insulation under the condition of light contamination and high electric stress
    • Paper 0.1, Vaasa
    • D. Konig, "Surface and Ageing Phenomena on Organic Insulation under the Condition of Light Contamination and High Electric Stress", Proceedings of the Nordic Insulation Symposium (NORD-IS), Paper 0.1, pp. 17-35, Vaasa, 1994.
    • (1994) Proceedings of the Nordic Insulation Symposium (NORD-IS) , pp. 17-35
    • Konig, D.1
  • 11
    • 0013256808 scopus 로고
    • The influence of moisture layers with increased volume conductivity on the partial discharge behavior of epoxy resin model insulators at short- and long time tests
    • Graz
    • O. Claus and D. Konig, "The Influence of Moisture Layers with Increased Volume Conductivity on the Partial Discharge Behavior of Epoxy Resin Model Insulators at Short- and Long Time Tests", Proceedings of the Ninth International Symposium on High Voltage Engineering, pp. 5598-1 - 5598-4, Graz, 1995.
    • (1995) Proceedings of the Ninth International Symposium on High Voltage Engineering , pp. 55981-55984
    • Claus, O.1    Konig, D.2
  • 12
    • 0032688010 scopus 로고    scopus 로고
    • AC and DC performance of polymeric housing materials for HV outdoor insulators
    • V. M. Moreno and R. S. Gorur, "AC and DC Performance of Polymeric Housing Materials for HV Outdoor Insulators", IEEE Trans. DEI, Vol. 6, pp. 342-350, 1999.
    • (1999) IEEE Trans. DEI , vol.6 , pp. 342-350
    • Moreno, V.M.1    Gorur, R.S.2
  • 14
    • 0002864737 scopus 로고
    • On the evaluation of the early aging period of polymer insulator surfaces during accelerated aging tests
    • Graz
    • R. Barsch, J. Lambrecht and H.-J. Winter, "On the Evaluation of the Early Aging Period of Polymer Insulator Surfaces During Accelerated Aging Tests", Proc. Ninth Intern. Symposium on High Voltage Engineering, pp. 3023-1-3023-4, Graz, 1995.
    • (1995) Proc. Ninth Intern. Symposium on High Voltage Engineering , pp. 30231-30234
    • Barsch, R.1    Lambrecht, J.2    Winter, H.-J.3
  • 16
    • 0032759627 scopus 로고    scopus 로고
    • Water drop corona effects on full-scale 500 kV non-ceramic insulators
    • A. J. Philips, D. J. Childs and H. M. Schneider, "Water Drop Corona Effects on Full-Scale 500kV Non-Ceramic Insulators", IEEE Trans. Power Delivery, Vol. 14, pp. 258-265, 1999.
    • (1999) IEEE Trans. Power Delivery , vol.14 , pp. 258-265
    • Philips, A.J.1    Childs, D.J.2    Schneider, H.M.3
  • 17
    • 0030105023 scopus 로고    scopus 로고
    • Consideration of corona onset from a water drop as a function of air pressure
    • A. J. Phillips, I. R. Jandrell and J. P. Reynders, "Consideration of Corona Onset from a Water Drop as a Function of Air Pressure", IEE Proc. Sci. Measurement Technology, Vol. 143, pp. 125-130, 1996.
    • (1996) IEE Proc. Sci. Measurement Technology , vol.143 , pp. 125-130
    • Phillips, A.J.1    Jandrell, I.R.2    Reynders, J.P.3
  • 18
    • 0004115584 scopus 로고    scopus 로고
    • National Instruments Corporation
    • "PCI-6110E/PCI-6111E User Manual", National Instruments Corporation, 1998.
    • (1998) PCI-6110E/PCI-6111E User Manual
  • 19
    • 0004114309 scopus 로고    scopus 로고
    • National Instruments Corporation
    • "LabVIEW User Manual", National Instruments Corporation, 1996.
    • (1996) LabVIEW User Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.